Organizer
Agilent Technologies
Agilent Technologies
Analytical scientists and clinical researchers worldwide rely on Agilent to help fulfill their most complex laboratory demands. Our instruments, software, services and consumables address the full range of scientific and laboratory management needs.
Tags
GC
GC/MS
Tips & Tricks
LinkedIn Logo

Optimizing the GC to Get the Analytes to the MS Efficiently

RECORD | Already taken place Th, 24.6.2021
In this presentation, we will discuss everything from the vial to end of the GC column as considerations when developing a method or optimizing a current one.
Go to the webinar
Agilent Technologies: Eliminate the Fear of Mass Spec
Agilent Technologies: Eliminate the Fear of Mass Spec

One of the most difficult tasks to create an optimal and efficient GC/MS method is getting the analytes from the vial to the MS without loss or changing to another compound. Due to the complexity of the MS, it is the first to be blamed for a poor injection when in fact transferring the analytes to the MS is the culprit.

Agilent GC parameters that might have been overlooked or not understood will be defined and explained with corresponding data. Recommended maintenance and cleaning procedures will be reviewed as well as how to minimize the investigation time for a problem to correct the issue and return to a proper functioning system. At the end of this presentation, a viewer will have a set of new or refined knowledge to be a more confident and efficient GC/MS user.

Presenter: Matt Curtis (GC/MS Applications Scientist, Agilent Technologies, Inc.)

Matt joined Agilent in 2013 as a GC/MS applications scientist in the Santa Clara, CA Center of Excellence, with GC/MS experience starting as an undergraduate. His primary responsibility is focused on providing instrument demos for customer interested in each technology Agilent offers; the GC/MS single quadrupole, triple quadrupole and the quadrupole Time-of-Flight. The variety of different applications submitted to the demo lab provide a unique knowledge of optimizing parameters for each experiment.

Agilent Technologies
LinkedIn Logo
 

Related content

Alcohol Determination of Sanitizer Gel Using Nexis GC-2060

Applications
| 2026 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Pharma & Biopharma

Sensitive and Reproducible Determination of Nitrosamines by GC/MSD

Applications
| 2026 | Agilent Technologies
Instrumentation
GC/MSD, GC/SQ
Manufacturer
Agilent Technologies
Industries
Environmental

High-Throughput BTEX Analysis in Nail Products by SPME and GC/TQ

Applications
| 2026 | Agilent Technologies
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ, SPME
Manufacturer
Agilent Technologies
Industries
Materials Testing

Accurate multi-component blast furnace gas analysis maximizes iron production and minimizes coke consumption

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
GC/MSD
Manufacturer
Thermo Fisher Scientific
Industries
Energy & Chemicals

Gas Chromatograph Nexis GC-2060

Brochures and specifications
| 2026 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Other
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike