GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike
Organizer
Separation Science
Separation Science
Separation Science is the leading online resource for methods, applications, troubleshooting and training in chromatography and mass spectrometry.
Tags
GC
GC/MS
Consumables
Columns
Tips & Tricks
LinkedIn Logo

Maintaining Sensitivity and Peak Shape on GC and GC/MS over Time

RECORD | Already taken place We, 28.10.2020
Separation Science, in collaboration with Agilent, offers an upcoming webinar providing solutions for maximizing sensitivity and maintaining peak shape of analyses on your GC or GC/MS system.
Go to the webinar
Pixabay/Andreas Lischka: Maintaining Sensitivity and Peak Shape on GC and GC/MS over Time
Pixabay/Andreas Lischka: Maintaining Sensitivity and Peak Shape on GC and GC/MS over Time

Have you maximized the sensitivity of your analyses on your GC or GC/MS system? Are your peak shapes optimal, or do they tail and have shoulders? Matching the correct injection style, supplies, column type and column flow can bring an analysis to the next level.

This webinar will delve into the sensitivity of different GC detectors — yes, mass spectrometers (single quad and triple quad!) and non-MS detectors — and optimizing the GC supplies and parameters for the best separation and peak shape as the analytes head into the detector.

We’ll also compare column styles and carrier gas parameters, and then discuss troubleshooting steps for split and split-less injections – how to step back and check the problem source: parameters or instrument. Moreover, there is more to a mass spec than Scan; we’ll delve into SIM for the single quad and MRM for the triple quad with discussion on setting up parameters like dwell times and dynamic MRM.

What does it cover?

  • Sensitivity of non-MS and MS detectors
  • Understanding column flow (constant flow vs. constant pressure and why it matters)
  • Liner and column selection for select applications, such as pesticides applications across multiple detectors
  • Comparison of ms UI columns and bleed stability over time
  • Choosing and troubleshooting split or split-less injections
  • Using Scan/SIM and or MRM to maximize sensitivity and how to set up the parameters for SIM and MRM.

By attending this webinar you will learn...

  • about maintaining sensitivity and peak shapes in your analyses with a GC (and GC/MS) system through column selection and the correct injection and column flow styles
  • how to set-up your GC(MS) system to maximize the ability (and sensitivity) of the single quad and triple quad mass spectrometers with setting up SIM and MRM parameters.

Presenter: Angie Smith-Henry (GC Applications Chemist, Agilent)

Angie is is an applications chemist for GC and MS Supplies at Agilent in Wilmington, Delaware, USA. Previously, she was an applications chemist for the MSD Solutions and Applications group with a focus on developing analysers and applications for energy, chemical and environmental markets. Angie holds a PhD in Physical Chemistry from Lehigh University and BS in Chemistry from Juniata College.

Presenter: Vanessa Abercrombie (GC Applications Chemist, Agilent)

Vanessa is a GC applications chemist at Agilent in Folsom, California, USA. Vanessa has a broad background in GC and GC/MS, including experience as an instrument chemist at Bode Technology in Virginia working under contract to the FBI’s Laboratory Division. Prior to that, Vanessa worked for ETS Labs in St. Helena, California as an Analytical Chemist where she researched and developed quantitative separations by GC/MS and UHPLC for beer, wine and spirits. She holds a Master of Forensic Science from The George Washington University and a Bachelor of Arts in Chemistry from Sonoma State University.

Separation Science
LinkedIn Logo
 

Related content

Analysis of Aroma Components in Apples Using the Smart Aroma Database

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Food & Agriculture

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GCMS System (Carrier Gas: H2)

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Energy & Chemicals

What Causes GC Capillary Column Performance Degradation, and How Can I Prevent It?

Technical notes
| 2026 | Agilent Technologies
Instrumentation
Consumables, GC columns
Manufacturer
Agilent Technologies
Industries
Other

Aromatic Component Analysis of Gasoline According to ASTM D5580 Using the Brevis GC- 2050 Gas Chromatograph

Applications
| 2025 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Energy & Chemicals

Micro GC Analysis of Permanent Gas Impurities in PEM Fuel Cell-Grade Hydrogen

Applications
| 2025 | Agilent Technologies
Instrumentation
GC
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike