Achieving the Pesticide MRLs with GC/MS/MS Using Hydrogen Carrier Gas

RECORD | Already taken place Th, 20.4.2023
This presentation discusses the key strategies for analyzing pesticides with hydrogen carrier gas while delivering high-quality uncompromised results.
Go to the webinar
C&EN: Achieving the Pesticide MRLs with GC/MS/MS Using Hydrogen Carrier Gas
C&EN: Achieving the Pesticide MRLs with GC/MS/MS Using Hydrogen Carrier Gas

Recurring helium shortages and increased prices boost the demand for performing GC/MS analysis with alternative carrier gasses. While helium is the best carrier gas for GC/MS, hydrogen is the second-best alternative. However, unlike helium, hydrogen is not an inert gas. Hence, it can cause peak tailing, distorted ion ratios in the mass spectrum, poor library matching, and sensitivity loss.

Pesticides analysis can be challenging even with helium carrier gas given their diverse and labile nature. This presentation discusses the key strategies for analyzing pesticides with hydrogen carrier gas while delivering high-quality uncompromised results. To achieve the required detection limits with hydrogen carrier gas, the injection conditions were optimized. Further, the EI source optimized for use with hydrogen carrier gas allowed for preventing undesirable in-source reactions. Finally, method translation, and retention time locking techniques allowed the use of the MRM transitions and retention times from the database created with helium carrier gas.

Key Learning Objectives:
  • Optimization of GC conditions essential when using hydrogen carrier gas
  • Appropriate MS hardware selection, including the EI source optimized for use with hydrogen carrier gas
  • Method translation technique for maintaining the same retention times as the original method with helium carrier gas or to scale the analysis speed with accurate retention time prediction
Who Should Attend:
  • Laboratory Managers
  • Chromatographers
  • Product Developers

Presenter: Anastasia Andrianova (GC/MS Applications Scientist, Agilent Technologies)

Presenter: Melissa O'Meara (Forensic Science Consultant, C&EN Media Group)

C&EN
LinkedIn Logo
 

Related content

Quantitative Volatile PFAS Analysis in Textiles

Applications
| 2026 | Agilent Technologies
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Agilent Technologies
Industries
Materials Testing

Effectiveness of the MonoTrap Collection Method for VOC Analysis in Exhaled Breath Using GC-MS

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, Thermal desorption, GC/SQ
Manufacturer
Shimadzu
Industries
Clinical Research

Rapid analysis of organochlorine pesticides (OCPs) in soil samples using the EXTREVA ASE accelerated solvent extractor

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
Sample Preparation, GC
Manufacturer
Thermo Fisher Scientific
Industries
Environmental

Total Hydrocarbon Impurity Analysis in PEM Fuel Cell Grade Hydrogen Using the Agilent 8890 GC-FID System

Applications
| 2026 | Agilent Technologies
Instrumentation
GC
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

Analysis of Aroma Components in Apples Using the Smart Aroma Database

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Food & Agriculture
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike