GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike
Organizer
Thermo Fisher Scientific
Thermo Fisher Scientific
A unique company dedicated to serving science helping our customers drive productivity and accelerate results. Through our premier brands – Thermo Scientific, Applied Biosystems, Invitrogen, Fisher Scientific and Unity Lab Services.
Tags
GC
GC/MS
Sample prep
LinkedIn Logo

Benefits of automated sample preparation workflow to reduce costs and increase lab efficiency

RECORD | Already taken place Tu, 30.6.2020
Automating sample derivatization for FAME characterization is key to release labor workload, reduce hazardous chemical exposure and get highly repeatable data for fat content profiling in food.
Go to the webinar
Thermo Fisher Scientific: Benefits of automated sample preparation workflow to reduce costs and increase lab efficiency
Thermo Fisher Scientific: Benefits of automated sample preparation workflow to reduce costs and increase lab efficiency

Exploring the benefits of unattended automated sample derivatization prior to GC analysis: the case of FAMEs.

Automating sample derivatization for FAME characterization is key to release labor workload, reduce hazardous chemical exposure and get highly repeatable data for fat content profiling in food.

Sample derivatization is often used in GC and GC/MS analyses to enhance the volatility of certain compounds. This is the case of the characterization of fats and oils in foods, where lipids are extracted with a non-polar solvent and saponified to produce free fatty acids. Then, the esterification to fatty acid methyl esters (FAME) is a very common derivatization procedure to increase volatility, improve chromatography, and decrease sample activity, thus providing more accurate analytical data.

Although it is a proven procedure commonly used to control fat quality in food, quantitative analysis of fat composition is extremely challenging especially when samples are processed manually. The use of highly toxic chemicals and large solvent volumes make this procedure troublesome while hand-on operations may lead to mistakes, poor accuracy and precision of the results.

A system capable of automatically handling much of the sample preparation process and scale down reagents and solvent consumption can increase laboratory throughput, reduce operational costs and free the operator from hazardous chemicals exposure, time-consuming and error-prone steps.

What you will learn:

  • Automate sample derivatization workflow for fatty acids profiling
  • Improve accuracy and precision of quantitative data through automation
  • Approach cost-saving by reducing reagents consumption and wastes

Daniela Cavagnino (Product Marketing Manager GC and Sampling Solutions, Thermo Fisher Scientific)

Dr. Daniela Cavagnino received her Masters Degree in Chemistry at the University of Milan, Italy. She started her career in gas chromatography at Thermo Fisher Scientific spending several years in the R&D laboratories working on GC technology innovation. Then, she conveyed her technical background into product management and marketing management roles with more than 15 years experience in promoting GC/GCMS technology and applications in several different market segments.

Thermo Fisher Scientific
LinkedIn Logo
 

Related content

Analysis of Aroma Components in Apples Using the Smart Aroma Database

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Food & Agriculture

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GCMS System (Carrier Gas: H2)

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Energy & Chemicals

What Causes GC Capillary Column Performance Degradation, and How Can I Prevent It?

Technical notes
| 2026 | Agilent Technologies
Instrumentation
Consumables, GC columns
Manufacturer
Agilent Technologies
Industries
Other

Aromatic Component Analysis of Gasoline According to ASTM D5580 Using the Brevis GC- 2050 Gas Chromatograph

Applications
| 2025 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Energy & Chemicals

Micro GC Analysis of Permanent Gas Impurities in PEM Fuel Cell-Grade Hydrogen

Applications
| 2025 | Agilent Technologies
Instrumentation
GC
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike