GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike
Organizer
Agilent Technologies
Analytical scientists and clinical researchers worldwide rely on Agilent to help fulfill their most complex laboratory demands. Our instruments, software, services and consumables address the full range of scientific and laboratory management needs.
Tags
GC/MS
GC/MS/MS
Logo of LinkedIn

RAFA 2021: Analysis of Ethylene Oxide and 2-Chloroethanol Residues in Sesame and other food commodities by GCMS/MS

RECORD | Already taken place We, 3.11.2021
Integration of the Automated Liner Exchange and pre-column backflush allows to perform analysis of ETO and 2CE with minimal downtime related to inlet maintenance, column exchange or source maintenance.
Go to the webinar
Agilent Technologies/RAFA 2021: Analysis of Ethylene Oxide and 2-Chloroethanol Residues in Sesame and other food commodities by GCMS/MS

Agilent Technologies/RAFA 2021: Analysis of Ethylene Oxide and 2-Chloroethanol Residues in Sesame and other food commodities by GCMS/MS

The unauthorized presence of ethylene oxide (ETO) and 2-chloroethanol (2CE) in food is a new emerging food safety issue. To ensure that foods are safe for consumption, food industry and enforcement agencies need reliable and robust methods.

For their determination a combination of a QuEChERS sample preparation method and a GC-MS/MS analytical method was proposed by the EU Reference Laboratories for Residues of Pesticides. However, several challenges are encountered when it comes to the analysis of ETO and 2CE. QuEChERS extracts often contain high amounts of non-volatile material which can accumulate in the inlet liner and column, affecting the accuracy and robustness of the analysis.

Integration of the Automated Liner Exchange (ALEX) option and pre-column backflush allows to perform analysis of ETO and 2CE with minimal downtime related to inlet maintenance, frequent analytical column exchange or source maintenance.

Presenter: Tatiana Cucu Ph.D (Senior Scientist/Project Manager, Research Institute for Chromatography (RIC Group), Kortrijk, Belgium)

Agilent Technologies
 

Related content

Utilizing hyphenated EC-Raman to study a model system

Applications
| 2024 | Metrohm
Instrumentation
RAMAN Spectroscopy
Manufacturer
Metrohm
Industries
Energy & Chemicals

Downstream Petrochemical Processes - Application Compendium

Guides
| 2024 | Agilent Technologies
Instrumentation
GC
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

Analysis of VOC and SVOC Emissions from Automotive Interior Materials Using GCMS-QP2050 in Accordance with VDA 278

Applications
| 2024 | Shimadzu
Instrumentation
Thermal desorption, GC/MSD, GC/SQ
Manufacturer
Shimadzu
Industries
Materials Testing

OMNIS NIRS

Brochures and specifications
| 2024 | Metrohm
Instrumentation
NIR Spectroscopy, Software
Manufacturer
Metrohm
Industries
Others

PEGASUS BTX Series

Brochures and specifications
| 2024 | LECO
Instrumentation
GC/MSD, GC/TOF
Manufacturer
LECO
Industries
Others
Other projects
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike