GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike
Organizer
Plasmion
Plasmion
We provide a novel sensor technology based on ambient mass spectrometry which does not only improve the utilization in traditional laboratory environments, but also enables the transfer of this kind of sensor technology to industrial process control, forensics, security technology (drugs, explosives, etc.) and the medical "point of care"​ diagnostics.
Tags
GC/MS
SPME
LC/MS
LinkedIn Logo

Direct MS Screening - Get Results Faster with SICRIT

RECORD | Already taken place Mo, 4.5.2020
Ion source SICRIT® direct screening possibility provides three advantages for existing (routine) analyses and reducing complexity of mass spectrometry in terms of preparation, execution and evaluation.
Go to the webinar
Plasmion: Direct MS Screening - Get Results Faster with SICRIT
Plasmion: Direct MS Screening - Get Results Faster with SICRIT

Direct screening enables fast identification and comparison of substances

Fast & Direct Screening enables to identify or compare different substances without any sample preparation.

Screening with quantification delivers reliable concentration levels

Screening with quantification not only enables a fast identification of substances but also provides reliable information about concentration levels to compare with standards or thresholds.

Automated all-in-one workflow simplifies routine analytics

All-in-one-Workflow reduces effort and cost in routine analytics as it enables to only perform detailed GC-MS analysis for positively screened samples.

Conventional Ionization Technologies

With conventional atmospheric pressure methods, the ions are mostly formed outside the inlet of an MS. This implies that the substance to be analyzed (e.g. coffee) cannot be analyzed directly, but is usually "sprayed" into the MS in the form of a sample (liquid extract) via the ionization source.

SICRIT® Technology

The SICRIT® (Soft Ionization by Chemical Reaction In Transfer) ionization source is interfaced with the atmospheric pressure inlet of the MS and ionizes every substance which is drawn into the MS by its inherent vacuum.

Plasmion: Conventional MS Ionization Technologies vs. SICRIT® TechnologyPlasmion: Conventional MS Ionization Technologies vs. SICRIT® Technology

SICRIT® Characteristics

  • Simple extension of MS inlet
  • Concentric dielectric barrier discharge
  • Sample ionized during transfer into MS
  • Soft ionization by proton transfer and UV light
  • No consumables
Plasmion
LinkedIn Logo
 

Related content

Analysis of Aroma Components in Apples Using the Smart Aroma Database

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Food & Agriculture

Analysis of Acetaldehyde and Limonene in Recycled PET Using an HS-GCMS System (Carrier Gas: H2)

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Energy & Chemicals

What Causes GC Capillary Column Performance Degradation, and How Can I Prevent It?

Technical notes
| 2026 | Agilent Technologies
Instrumentation
Consumables, GC columns
Manufacturer
Agilent Technologies
Industries
Other

Aromatic Component Analysis of Gasoline According to ASTM D5580 Using the Brevis GC- 2050 Gas Chromatograph

Applications
| 2025 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Energy & Chemicals

Micro GC Analysis of Permanent Gas Impurities in PEM Fuel Cell-Grade Hydrogen

Applications
| 2025 | Agilent Technologies
Instrumentation
GC
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike