Organizer
Plasmion
Plasmion
We provide a novel sensor technology based on ambient mass spectrometry which does not only improve the utilization in traditional laboratory environments, but also enables the transfer of this kind of sensor technology to industrial process control, forensics, security technology (drugs, explosives, etc.) and the medical "point of care"​ diagnostics.
Tags
GC/MS
SPME
LC/MS
LinkedIn Logo

Direct MS Screening - Get Results Faster with SICRIT

RECORD | Already taken place Mo, 4.5.2020
Ion source SICRIT® direct screening possibility provides three advantages for existing (routine) analyses and reducing complexity of mass spectrometry in terms of preparation, execution and evaluation.
Go to the webinar
Plasmion: Direct MS Screening - Get Results Faster with SICRIT
Plasmion: Direct MS Screening - Get Results Faster with SICRIT

Direct screening enables fast identification and comparison of substances

Fast & Direct Screening enables to identify or compare different substances without any sample preparation.

Screening with quantification delivers reliable concentration levels

Screening with quantification not only enables a fast identification of substances but also provides reliable information about concentration levels to compare with standards or thresholds.

Automated all-in-one workflow simplifies routine analytics

All-in-one-Workflow reduces effort and cost in routine analytics as it enables to only perform detailed GC-MS analysis for positively screened samples.

Conventional Ionization Technologies

With conventional atmospheric pressure methods, the ions are mostly formed outside the inlet of an MS. This implies that the substance to be analyzed (e.g. coffee) cannot be analyzed directly, but is usually "sprayed" into the MS in the form of a sample (liquid extract) via the ionization source.

SICRIT® Technology

The SICRIT® (Soft Ionization by Chemical Reaction In Transfer) ionization source is interfaced with the atmospheric pressure inlet of the MS and ionizes every substance which is drawn into the MS by its inherent vacuum.

Plasmion: Conventional MS Ionization Technologies vs. SICRIT® TechnologyPlasmion: Conventional MS Ionization Technologies vs. SICRIT® Technology

SICRIT® Characteristics

  • Simple extension of MS inlet
  • Concentric dielectric barrier discharge
  • Sample ionized during transfer into MS
  • Soft ionization by proton transfer and UV light
  • No consumables
Plasmion
LinkedIn Logo
 

Related content

Streamlined static headspace GC–MS approach for detection of impurities in recycled PET

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
GC/MSD, HeadSpace, GC/SQ
Manufacturer
Thermo Fisher Scientific
Industries
Materials Testing

Run Smarter, Go Greener: Smart Energy Saving In Nexis GC-2060

Brochures and specifications
| 2026 | Shimadzu
Instrumentation
GC
Manufacturer
Shimadzu
Industries
Other

Gas Chromatograph Mass Spectrometer GCMS-TQ RX Series

Brochures and specifications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Shimadzu
Industries
Other

Hydrogen Carrier Gas Method Translation in Comprehensive Two- Dimensional Gas Chromatography for Sustainable Nontargeted Analysis

Scientific articles
| 2026 | William & Mary
Instrumentation
GCxGC, GC/MSD, GC/MS/MS, GC/TOF, GC/HRMS
Manufacturer
LECO
Industries
Other

Novel data processing workflow including in-silico derivatization for integrated CI & EI MS data acquired with the GC-ecTOFinstrument

Posters
| 2026 | Bruker (ASMS)
Instrumentation
GC/MS/MS, GC/MSD, GC/TOF, GC/HRMS
Manufacturer
Bruker
Industries
Metabolomics
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike