Organizer
Agilent Technologies
Agilent Technologies
Analytical scientists and clinical researchers worldwide rely on Agilent to help fulfill their most complex laboratory demands. Our instruments, software, services and consumables address the full range of scientific and laboratory management needs.
Tags
GC/MS
GC/MS/MS
LinkedIn Logo

Analysis of ethylene oxide and 2-chloroethanol in sesame seeds and other food commodities: challenges and solutions

RECORD | Already taken place We, 29.9.2021
A robust analytical solution was obtained with an Agilent 8890 GC/7010 QQQ MS and a Gerstel MPS sampler ensuring less downtime related to inlet maintenance, column changing and/or MS source cleaning.
Go to the webinar
Pixabay/Ulrike Leone: Analysis of ethylene oxide and 2-chloroethanol in sesame seeds and other food commodities: challenges and solutions
Pixabay/Ulrike Leone: Analysis of ethylene oxide and 2-chloroethanol in sesame seeds and other food commodities: challenges and solutions

Non-authorized presence of ethylene oxide (ETO) and 2-chloroethanol (2CE) in sesame seeds and other food commodities is a new emerging food safety issue. First notification about the presence of ETO in sesame seeds dates from August 2020, and since then over 500 new notifications were published on the European Rapid Alert Food and Feed Safety (RASFF) portal. To ensure that foods are safe for consumption, food industry and enforcement agencies need reliable and robust methods to detect ETO and 2CE in foods preferably at levels at or below the set maximum residue limit of 0.05 mg/kg.

For the determination of these contaminants a combination of a QuEChERS sample preparation method and a GC-MS/MS analytical method was proposed by the EU Reference Laboratories for Residues of Pesticides. However, several challenges are encountered when it comes to the analysis of ETO and 2CE in various food products. The high volatility of ETO requires the use of a dedicated column to ensure separation from possible interference from acetaldehyde.

Secondly, QuEChERS extracts often contain high amounts of non-volatile material which can accumulate in the inlet liner and column inlet, affecting the accuracy and robustness of the analysis. Integration of the Automated Liner Exchange (ALEX) option in the analysis of ETO and 2CE allowed to exchange the GC liner without stopping the analysis sequence and therefore with no downtime related to inlet maintenance.

Additionally, the analytical column was further protected by the integration of a pre-column with backflushing option. This allowed to remove high boiling compounds which reach the analytical column. Back-flushing was carried out while the analysis was occurring on the analytical column, keeping sample throughput unaffected.

With this dedicated set-up based on an Agilent 8890 GC, an Agilent 7010 triple quadrupole MS and a Gerstel MPS sampler, a robust analytical solution was obtained, ensuring less downtime related to inlet maintenance, column changing and/or MS source cleaning. Limits of detection in the low range of µg/kg with excellent recovery and repeatability were obtained for sesame and curcuma samples.

What you will learn:

Attendees will learn about how to deal with the analytical challenges of the determination of ETOX and 2-CE in food commodities and how a novel, robust and automated method can be implemented in their labs

Who should attend:

Food safety chemists, researchers and lab managers

Presenter: Tatiana Cucu, Ph.D. (Senior Scientist/Project manager, Research Institute for Chromatography (RIC))

Tatiana received her Ph.D. degree in the field of food safety and food quality in 2011 at University of Gent, Belgium. During her Ph.D. and later during her post-doc she developed analytical methods for the analysis of among other food allergens and food additives. In 2005 she joined the Research Institute for Chromatography (RIC) as senior scientist where she is involved in project related to development and optimisation of GC-MS and GC-MS/MS methods, miniaturisation and automatization of sample preparation methods and development of new applications for food, environmental, pharmaceutical, and chemical industries.

Agilent Technologies
LinkedIn Logo
 

Related content

Quantitative Volatile PFAS Analysis in Textiles

Applications
| 2026 | Agilent Technologies
Instrumentation
GC/MSD, GC/MS/MS, GC/QQQ
Manufacturer
Agilent Technologies
Industries
Materials Testing

Effectiveness of the MonoTrap Collection Method for VOC Analysis in Exhaled Breath Using GC-MS

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, Thermal desorption, GC/SQ
Manufacturer
Shimadzu
Industries
Clinical Research

Rapid analysis of organochlorine pesticides (OCPs) in soil samples using the EXTREVA ASE accelerated solvent extractor

Applications
| 2026 | Thermo Fisher Scientific
Instrumentation
Sample Preparation, GC
Manufacturer
Thermo Fisher Scientific
Industries
Environmental

Total Hydrocarbon Impurity Analysis in PEM Fuel Cell Grade Hydrogen Using the Agilent 8890 GC-FID System

Applications
| 2026 | Agilent Technologies
Instrumentation
GC
Manufacturer
Agilent Technologies
Industries
Energy & Chemicals

Analysis of Aroma Components in Apples Using the Smart Aroma Database

Applications
| 2026 | Shimadzu
Instrumentation
GC/MSD, GC/SQ, HeadSpace
Manufacturer
Shimadzu
Industries
Food & Agriculture
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike