Agilent 7890B GC Supplies - Quick reference guide
Guides | 2018 | Agilent TechnologiesInstrumentation
High-quality consumables and replacement parts are crucial for maintaining the performance, reliability, and uptime of gas chromatographs. Proper selection and timely replacement of supplies minimize instrument downtime and preserve analytical accuracy in routine and advanced applications.
This guide compiles the most commonly ordered supplies for the Agilent 7890B GC. It is designed to help laboratories quickly identify the correct vials, caps, filters, liners, ferrules, and detector components to streamline maintenance, procurement, and instrument uptime.
The Agilent 7890B gas chromatograph serves as the reference platform. Supplies are organized by functional category:
Key recommendations include:
Utilizing genuine Agilent consumables ensures
Emerging developments may include more robust inert materials for septa and liners, integrated sensor systems for real-time consumable status monitoring, automated parts reordering through instrument software, and sustainable designs to reduce laboratory waste.
Implementing a structured consumable replacement schedule with recommended supplies is critical to maximizing the uptime and analytical integrity of the Agilent 7890B GC system.
Agilent Technologies. Agilent 7890B GC Supplies Quick Reference Guide. 2018.
GC, Consumables
IndustriesManufacturerAgilent Technologies
Summary
Importance of the Topic
High-quality consumables and replacement parts are crucial for maintaining the performance, reliability, and uptime of gas chromatographs. Proper selection and timely replacement of supplies minimize instrument downtime and preserve analytical accuracy in routine and advanced applications.
Objectives and Overview
This guide compiles the most commonly ordered supplies for the Agilent 7890B GC. It is designed to help laboratories quickly identify the correct vials, caps, filters, liners, ferrules, and detector components to streamline maintenance, procurement, and instrument uptime.
Methodology and Instrumentation
The Agilent 7890B gas chromatograph serves as the reference platform. Supplies are organized by functional category:
- Sample Introduction Supplies: vials (crimp‐top and screw‐top), caps, and septa.
- Gas Handling Supplies: Gas Clean filter kits and replacement filters for carrier, oxygen, moisture, and hydrocarbon lines.
- Inlet System Supplies: septa (BTO, Advanced Green, long‐life), O-rings, gold seals, and split vent trap cartridges.
- Inlet Liners: split, splitless, and straight liners with options for ultra-inert deactivation.
- Column Connection Supplies: ferrules (graphite, Vespel/graphite, flexible metal) sized for 0.25–0.53 mm ID columns and compatible nuts (standard, deep well, self‐tightening).
- Detector Supplies: FID jets, fittings, ignitors, and collector bodies; MSD transfer line interface nuts, ferrules, EI filaments, and handheld diagnostic tools.
Main Results and Discussion
Key recommendations include:
- Bleed-optimized inlet septa rated for specific temperatures (350–400 °C) and injection lifetimes.
- Regular replacement of Gas Clean filters and inline kits to ensure carrier and detector gas purity.
- Use of ultra-inert liners and gold seals to reduce active sites, minimize bleed, and improve peak shape.
- Selection of ferrule materials and column nuts to prevent leaks and contamination across different column IDs and detector configurations.
- Maintenance of FID and MSD components with manufacturer-specified jets, ignitors, collector parts, and diagnostic cartridges.
Benefits and Practical Applications
Utilizing genuine Agilent consumables ensures
- Leak-free connections and consistent retention times.
- Low column bleed for trace analysis.
- Reproducible results in QA/QC, environmental, food, and petrochemical laboratories.
- Extended maintenance intervals and reduced risk of unexpected downtime.
Future Trends and Applications
Emerging developments may include more robust inert materials for septa and liners, integrated sensor systems for real-time consumable status monitoring, automated parts reordering through instrument software, and sustainable designs to reduce laboratory waste.
Conclusion
Implementing a structured consumable replacement schedule with recommended supplies is critical to maximizing the uptime and analytical integrity of the Agilent 7890B GC system.
Reference
Agilent Technologies. Agilent 7890B GC Supplies Quick Reference Guide. 2018.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent 8890 and 8860 GC Supplies - Quick Reference Guide
2019|Agilent Technologies|Brochures and specifications
Quick Reference Guide Agilent 8890 and 8860 GC Supplies Agilent supplies for Agilent instruments Agilent is committed to optimizing your laboratory’s productivity, so we have produced this list of the most commonly ordered supplies and parts for the 8890 and…
Key words
yes, yessupplies, suppliespart, partnumber, numberclean, cleangraphite, graphitesepta, septawax, waxgas, gaswool, wooladm, admfilter, filterwasher, washerseal, sealmsd
Agilent GC AND GC/MS - Catalog Consumables and Spare Parts
2016|Agilent Technologies|Others
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG For more information This information is subject to change without notice. © Agilent Technologies, Inc. 2016 Printed in Canada March 8, 2016 5991-5213EN GC AND GC/MS Your Essential…
Key words
supplies, suppliesagilent, agilentparts, partscrosslab, crosslabdescription, descriptionoem, oemnut, nutinlet, inletliners, linerssepta, septaferrule, ferrulecolumn, columnneedle, needlestick, stickassembly
Better Connections - Agilent GC inlet resource guide
2021|Agilent Technologies|Guides
Better Connections, Better Results with Your Agilent GC System GC inlet resource guide Here’s What’s Inside Introduction Septa Troubleshooting Ordering Information Ferrules Troubleshooting Ordering Information 2 3 4 4 7 8 9 13 Column Nuts Ordering Information Liners 14 15…
Key words
liner, linerproblem, probleminlet, inletferrules, ferrulescolumn, columnnormal, normalgraphite, graphitenut, nutliners, linersnuts, nutssepta, septaferrule, ferruleagilent, agilentwool, woolreplace
8890 Gas Chromatography (GC) System with 7693A Automatic Liquid Sampler (Essential Instrument Supplies)
2025|Agilent Technologies|Others
Essential Instrument Supplies Agilent technical experts have compiled a list of recommended supplies that you should consider using with your new instrument in order to keep your lab operational without any disruptions and to achieve optimal performance. 8890 Gas Chromatography…
Key words
recommendation, recommendationintuvo, intuvotop, tophydroinert, hydroinertferrules, ferrulesspecific, specificcolumn, columninlet, inletrecommended, recommendedrough, roughmsds, msdsmanagement, managementliners, linerssepta, septapart