The Agilent Intuvo GC –A New Way to Perform Gas Chromatographic Analyses for the Energy, Refining and Petrochemical Lab
Presentations | 2017 | Agilent TechnologiesInstrumentation
Gas chromatography remains essential for quality control and regulatory compliance in energy, refining, and petrochemical industries.
Key tasks include detecting trace sulfur compounds to prevent corrosion and reduce emissions, characterizing boiling-point distributions via simulated distillation, and assessing purity of aromatic feedstocks for polymer precursors.
Innovations that simplify operation, reduce footprint, and accelerate analysis support lean laboratories and sustainable practices.
This whitepaper introduces the Agilent Intuvo GC system, a modular, direct-heating gas chromatograph designed to be easier, faster, smaller, smarter, and greener.
It highlights three core applications relevant to refinery and petrochemical labs:
Advances in direct column heating and modular design will enable further miniaturization and potential field-deployable systems.
Integration with mass spectrometry and multi-dimensional separations may extend capabilities for complex samples.
Cloud-enabled diagnostics and AI-driven method optimization could streamline workflows and enhance data quality.
The Agilent Intuvo GC combines direct heating, disposable flow chips, and a smart interface to deliver robust, high-speed analyses.
Applications in sulfur detection, simulated distillation, and aromatic purity confirm its value for labs seeking efficiency, reliability, and regulatory compliance.
GC
IndustriesEnergy & Chemicals
ManufacturerAgilent Technologies
Summary
Importance of the Topic
Gas chromatography remains essential for quality control and regulatory compliance in energy, refining, and petrochemical industries.
Key tasks include detecting trace sulfur compounds to prevent corrosion and reduce emissions, characterizing boiling-point distributions via simulated distillation, and assessing purity of aromatic feedstocks for polymer precursors.
Innovations that simplify operation, reduce footprint, and accelerate analysis support lean laboratories and sustainable practices.
Aims and Overview of the Study
This whitepaper introduces the Agilent Intuvo GC system, a modular, direct-heating gas chromatograph designed to be easier, faster, smaller, smarter, and greener.
It highlights three core applications relevant to refinery and petrochemical labs:
- Sulfur compound detection in light petroleum using sulfur chemiluminescence detection (SCD) aligned with ASTM D5623.
- Ultrafast simulated distillation of middle distillates following ASTM D7798.
- Aromatic solvent purity analysis according to ASTM D7504.
Methodology and Instrumentation Used
- Agilent Intuvo GC platform integrates disposable guard chips, ferrule-free click-and-run connectors, and direct heating of planar capillary columns.
- Inlets include split/splitless (SSL) or multimode inlet (MMI) with inert liners and micro-seals.
- Detectors: flame ionization (FID) with autoranging electronics and sulfur chemiluminescence (SCD).
- Columns: DB-1 and HP-Innowax capillaries with precise helium carrier flow control.
- Automation support for autosamplers, headspace, thermal desorption, and purge-and-trap modules.
- Graphical user interface provides real-time chromatograms, step-by-step maintenance, and Health Report diagnostics.
Main Results and Discussion
- Sulfur Analysis (ASTM D5623): Achieved 20 ppb detection of 23 sulfur species with limits around 2 ppb and signal-to-noise ratios >2 for most compounds. Calibration linearity (R2>0.997) and repeatability (RSD<5%) were confirmed. NIST 2298/2299 reference fuels yielded total sulfur within specified ranges.
- Ultrafast Simulated Distillation (ASTM D7798): Direct column heating achieved ramp rates up to 250 °C/min with retention time precision better than 0.003 min. Discrimination was minimized and boiling-point cuts matched conventional D2887 within ±5 °C.
- Aromatic Solvent Purity (ASTM D7504): Autoranging FID quantified major (>99%) and minor (ppm) components in a single run. Mixed xylene and toluene tests met ASTM repeatability and precision criteria.
Benefits and Practical Applications
- Compact footprint and lower energy consumption support lean operations and reduce environmental impact.
- Modular flow chips and user-friendly connectors simplify maintenance and minimize downtime.
- Autoranging FID and SCD extend dynamic range from ppm to percent levels without hardware changes.
- High heating rates and precise electronic pressure control shorten run times and improve throughput.
Future Trends and Applications
Advances in direct column heating and modular design will enable further miniaturization and potential field-deployable systems.
Integration with mass spectrometry and multi-dimensional separations may extend capabilities for complex samples.
Cloud-enabled diagnostics and AI-driven method optimization could streamline workflows and enhance data quality.
Conclusion
The Agilent Intuvo GC combines direct heating, disposable flow chips, and a smart interface to deliver robust, high-speed analyses.
Applications in sulfur detection, simulated distillation, and aromatic purity confirm its value for labs seeking efficiency, reliability, and regulatory compliance.
References
- ASTM D5623: Sulfur in Light Petroleum Liquids by GC with Sulfur Chemiluminescence Detection
- ASTM D7798: Ultrafast Simulated Distillation of Middle Distillates by GC
- ASTM D2887: Simulated Distillation of Petroleum Fractions
- ASTM D7504: Aromatic Solvent Purity Analysis by GC
- NIST 2298 and 2299 Gasoline Reference Materials
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
CHEMICAL PURITY ANALYSIS
2016|Agilent Technologies|Others
CHEMICAL PURITY ANALYSIS Technology Advantage: Agilent Intuvo 9000 GC with FID Introduction Monocyclic aromatic hydrocarbons are important commodity chemicals used to manufacture polymers. ASTM Committee D16 designates purity specifications for many of these chemicals. The ASTM D7405 method supports these…
Key words
xylene, xylenecumene, cumenetoluene, toluenepurity, purityaromatics, aromaticsethylbenzene, ethylbenzenestddev, stddevnonaromatics, nonaromaticsmonocyclic, monocyclicmeasure, measurecommodity, commoditynon, nonchemical, chemicaloperators, operatorsexperienced
Ultrafast Simulated Distillation of Middle Distillates Using ASTM Method D7798 on the Agilent Intuvo Gas Chromatograph
2019|Agilent Technologies|Applications
Application Note Energy & Chemicals Ultrafast Simulated Distillation of Middle Distillates Using ASTM Method D7798 on the Agilent Intuvo Gas Chromatograph Author James D. McCurry Agilent Technologies, Inc. Abstract ASTM method D7798 is designed to provide middle-distillate boiling range distribution…
Key words
boiling, boilingintuvo, intuvodistribution, distributionsetpoints, setpointsultrafast, ultrafastdistillate, distillatepoint, pointsimdis, simdisils, ilstemperature, temperaturerange, rangedistillates, distillatesastm, astmfuel, fuelmiddle
Fast Hydrocarbon and Sulfur Simulated Distillation Using the Agilent Low Thermal Mass (LTM) System on the 7890A GC and 355 Sulfur Chemiluminescence Detector
2008|Agilent Technologies|Applications
Fast Hydrocarbon and Sulfur Simulated Distillation Using the Agilent Low Thermal Mass (LTM) System on the 7890A GC and 355 Sulfur Chemiluminescence Detector Application Note Hydrocarbon Processing Authors Abstract ChunXiao Wang A fast multielement simulated distillation method (SimDis) based on…
Key words
simdis, simdisltm, ltmscd, scdsulfur, sulfurrgo, rgohydrocarbon, hydrocarbonfbp, fbpdistillation, distillationibp, ibpsimulated, simulatedscdnamer, scdnamerfid, fidbath, bathtemperature, temperatureair
Detection of Sulfur Compounds in Light Petroleum Liquids According to ASTM D5623 with the Agilent Dual Plasma Sulfur Chemiluminescence Detector and the Agilent Intuvo 9000 GC
2016|Agilent Technologies|Applications
Detection of Sulfur Compounds in Light Petroleum Liquids According to ASTM D5623 with the Agilent Dual Plasma Sulfur Chemiluminescence Detector and the Agilent Intuvo 9000 GC Application Note Author Abstract Rebecca Veeneman, PhD Sulfur compounds in gasoline samples are detected…
Key words
sulfur, sulfursulfide, sulfidedisulfide, disulfidelog, logcompounds, compoundspetroleum, petroleumdiethyl, diethylpractical, practicalthianaphthene, thianaphthenedimethyl, dimethylintuvo, intuvochemiluminescence, chemiluminescenceethylmethyl, ethylmethylbutanethiol, butanethioldiphenyl