Shimadzu Capillary Gas Chromatograph GC-2010 Pro
Brochures and specifications | 2020 | ShimadzuInstrumentation
Gas chromatography is a foundational tool in analytical chemistry for the analysis of volatile and semi volatile compounds. Its applications range from environmental monitoring and food safety testing to pharmaceutical quality control and petrochemical analysis. Advances in instrument design that deliver faster run times higher sensitivity and robust reproducibility can greatly enhance laboratory productivity and data quality.
This summary reviews the Shimadzu GC 2010 Pro capillary gas chromatograph which represents a next generation routine GC platform. The primary goals of this system are to reduce analysis time maximize sample throughput and maintain industry leading sensitivity and precision. Key innovations include rapid oven heating and cooling advanced flow control ergonomic operation and extensive scalability through modular injection and detection options.
The GC 2010 Pro employs a double jet cooling system for rapid temperature cycling and a high performance oven for fast heating. Dual analytical lines allow simultaneous runs with up to three detectors. An advanced electronic flow controller ensures constant linear velocity mode for optimal separation conditions. Gas saver functions reduce carrier gas consumption through split ratio control and automatic shutdown in idle periods. Narrow bore capillary columns enable high speed analysis while maintaining resolution.
Performance tests demonstrate peak area reproducibility with coefficients of variation below 0.4 percent for standard test mixtures in acetone. The oven cooling time from 450 to 50 degrees reduced from over four minutes in previous models to 3.4 minutes. High sensitivity detectors with noise reduction and dual focus optics improved detection limits for hydrocarbons phosphorous sulfur and organochlorine pesticides. Constant linear velocity control simplified method development and carrier gas savings cut helium use by over 80 percent during extended standby.
The GC 2010 Pro offers laboratories enhanced sample throughput cost savings and flexible configuration options. Its high reproducibility and trace level sensitivity are ideal for pesticide residue analysis flavor compound profiling and pharmaceutical impurity testing. Automated sampling and flow technologies streamline workflows while reducing maintenance and gas expenses.
Future developments may focus on further miniaturization integration of mass spectrometry detectors expanded automation artificial intelligence enabled method optimization and greener carrier gas alternatives. Connectivity with laboratory information management systems and cloud based data platforms may enhance remote monitoring spectral library sharing and predictive maintenance.
The Shimadzu GC 2010 Pro capillary gas chromatograph demonstrates significant improvements in speed sensitivity reproducibility and operational efficiency. Its modular design supports a wide range of analytical applications while reducing analysis time and cost. By combining advanced temperature control flow regulation and detector technology it meets the evolving demands of modern laboratories.
GC
IndustriesOther
ManufacturerShimadzu
Summary
Significance of the Topic
Gas chromatography is a foundational tool in analytical chemistry for the analysis of volatile and semi volatile compounds. Its applications range from environmental monitoring and food safety testing to pharmaceutical quality control and petrochemical analysis. Advances in instrument design that deliver faster run times higher sensitivity and robust reproducibility can greatly enhance laboratory productivity and data quality.
Objectives and Study Overview
This summary reviews the Shimadzu GC 2010 Pro capillary gas chromatograph which represents a next generation routine GC platform. The primary goals of this system are to reduce analysis time maximize sample throughput and maintain industry leading sensitivity and precision. Key innovations include rapid oven heating and cooling advanced flow control ergonomic operation and extensive scalability through modular injection and detection options.
Methodology
The GC 2010 Pro employs a double jet cooling system for rapid temperature cycling and a high performance oven for fast heating. Dual analytical lines allow simultaneous runs with up to three detectors. An advanced electronic flow controller ensures constant linear velocity mode for optimal separation conditions. Gas saver functions reduce carrier gas consumption through split ratio control and automatic shutdown in idle periods. Narrow bore capillary columns enable high speed analysis while maintaining resolution.
Used Instrumentation
- Shimadzu GC 2010 Pro capillary gas chromatograph
- Injection units including split splitless wide bore and programmable temperature vaporization on column injectors
- Detectors comprising flame ionization flame photometric electron capture thermal conductivity and flame thermionic types
- Auto injection systems such as AOC 20 series AOC 6000 and headspace samplers HS 10 HS 20
- Advanced flow modules for backflush heart cut detector splitting and detector switching
- LabSolutions workstation software for instrument control data acquisition and regulatory compliance
Main Results and Discussion
Performance tests demonstrate peak area reproducibility with coefficients of variation below 0.4 percent for standard test mixtures in acetone. The oven cooling time from 450 to 50 degrees reduced from over four minutes in previous models to 3.4 minutes. High sensitivity detectors with noise reduction and dual focus optics improved detection limits for hydrocarbons phosphorous sulfur and organochlorine pesticides. Constant linear velocity control simplified method development and carrier gas savings cut helium use by over 80 percent during extended standby.
Benefits and Practical Applications
The GC 2010 Pro offers laboratories enhanced sample throughput cost savings and flexible configuration options. Its high reproducibility and trace level sensitivity are ideal for pesticide residue analysis flavor compound profiling and pharmaceutical impurity testing. Automated sampling and flow technologies streamline workflows while reducing maintenance and gas expenses.
Future Trends and Potential Applications
Future developments may focus on further miniaturization integration of mass spectrometry detectors expanded automation artificial intelligence enabled method optimization and greener carrier gas alternatives. Connectivity with laboratory information management systems and cloud based data platforms may enhance remote monitoring spectral library sharing and predictive maintenance.
Conclusion
The Shimadzu GC 2010 Pro capillary gas chromatograph demonstrates significant improvements in speed sensitivity reproducibility and operational efficiency. Its modular design supports a wide range of analytical applications while reducing analysis time and cost. By combining advanced temperature control flow regulation and detector technology it meets the evolving demands of modern laboratories.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Shimadzu Gas Chromatograph Nexis GC-2030
2025|Shimadzu|Brochures and specifications
C184-E043E Gas Chromatograph Nexis GC-2030 GC-2030 The Next Industry Standard In today's environment, results are needed regardless of whether the analyst is working in the laboratory, the office, or from home. With the flexibility to accommodate a variety of applications,…
Key words
analysis, analysisgas, gasfunction, functionlabsolutions, labsolutionschromatograph, chromatographanaly, analydetector, detectorcarrier, carriersulfur, sulfurbeer, beerstatus, statusselector, selectorsystem, systemmind, mindhydrogen
High Mass Accuracy Provides Enhanced Selectivity for the GC/MS Analysis of Pesticides in Food
2011|Agilent Technologies|Posters
High Mass Accuracy Provides Enhanced Selectivity for the GC/MS Analysis of Pesticidees in Food ASMS 2011 WP 070 Th Thomas P P. D Doherty; h t Phil W Wylie; li Ch Chris i Sandy; S d Bill R Russ; A…
Key words
andd, anddoff, offastragalus, astragalusmass, masschamomile, chamomilefigure, figureeic, eicifi, ifiith, ithmasses, massesregion, regiontemp, tempmasshunter, masshunternoise, noisecalculator
Shimadzu Auto Injector/Auto Sampler AOC-20i/AOC-20s
2012|Shimadzu|Brochures and specifications
C189-E021J Auto Injector / Auto Sampler AOC-20i / AOC-20s Design goals set and surpassed in AOC-20 Series ...Ideal sample handling with high throughput, data reliability and traceability. Auto Injector AOC-20i Sample introduction is a key aspect of any gas chromatographic…
Key words
auto, autocooling, coolingsample, samplecti, ctifan, fanremarks, remarksinjector, injectorsolvent, solventsampler, samplerinjection, injectionsyringe, syringevials, vialsrack, racklabsolutions, labsolutionssecond
A Guide to GCMS Sample Introduction Systems: Choosing the best system for your analysis
2020|Shimadzu|Guides
C146-E433 A Guide to GCMS Sample Introduction Systems: Choosing the best system for your analysis APPLIC ATIONS OF GAS CHROMATOGR APHY Oil, Gas & Chemical Analysis of sulfur, inorganic gases & light hydrocarbons Environmental Testing Flavor & Fragrance Analysis of…
Key words
link, linkvolatile, volatileusabilit, usabilitdhs, dhsdirec, direction, tionsample, sampletrap, trapsolid, solidtrac, tracanalysis, analysisliq, liqenhancements, enhancementssemi, semishs