Quantification of Contact Allergens in Personal Care Products with GC and Full Mass Range TOFMS
Applications | 2016 | LECOInstrumentation
Certain fragrances and ingredients in personal care products can trigger contact allergies and irritation in sensitive consumers. Regulatory frameworks such as the European Cosmetics Directive mandate reporting of 26 specified contact allergens above threshold levels. Reliable analytical methods are essential for screening, quantification, and compliance.
This study evaluates the advantages of using full mass range time-of-flight mass spectrometry (TOFMS) coupled with gas chromatography (GC) for quantifying regulated contact allergens in complex cosmetic matrices. It compares targeted SIM approaches to comprehensive TOFMS acquisition and demonstrates automated calibration and deconvolution capabilities.
A set of allergen calibration standards (10 ppb–100 ppm) was prepared by serial dilution in isooctane. A leave-on perfume sample was diluted 100× prior to analysis.
All 26 regulated allergens were detected and identified using automated peak finding. Calibration curves for compounds such as geraniol exhibited excellent linearity (R² > 0.99) over four orders of magnitude. Full mass range data enabled recognition of coeluting matrix interferences that share diagnostic m/z values, which would skew quantification in a SIM‐only approach. Deconvolution algorithms isolated pure spectra of target analytes and interferences, allowing selection of unique m/z channels (e.g., m/z 123, 84 for geraniol) and accurate quantitation.
Advances in high-resolution TOFMS and automated data processing will further improve detection limits and throughput. Integration with robotic sample preparation and machine-learning algorithms could enable real-time allergen monitoring and broader screening of emerging sensitizers in personal care products.
GC-TOFMS with full mass range acquisition on the Pegasus HT provides robust, accurate, and efficient quantification of regulated contact allergens in personal care products. The combination of high speed, sensitivity, and deconvolution ensures reliable results and supports regulatory compliance without repetitive analyses.
GC/MSD, GC/TOF
IndustriesOther
ManufacturerAgilent Technologies, LECO
Summary
Significance of the Topic
Certain fragrances and ingredients in personal care products can trigger contact allergies and irritation in sensitive consumers. Regulatory frameworks such as the European Cosmetics Directive mandate reporting of 26 specified contact allergens above threshold levels. Reliable analytical methods are essential for screening, quantification, and compliance.
Objectives and Study Overview
This study evaluates the advantages of using full mass range time-of-flight mass spectrometry (TOFMS) coupled with gas chromatography (GC) for quantifying regulated contact allergens in complex cosmetic matrices. It compares targeted SIM approaches to comprehensive TOFMS acquisition and demonstrates automated calibration and deconvolution capabilities.
Methodology and Instrumentation
A set of allergen calibration standards (10 ppb–100 ppm) was prepared by serial dilution in isooctane. A leave-on perfume sample was diluted 100× prior to analysis.
- Gas Chromatograph: Agilent 7890 with MPS2 autosampler, 1 µL splitless injection at 250 °C
- Column: Rxi-5ms, 30 m × 0.25 mm i.d., 0.25 µm film
- Carrier Gas: Helium at 1.4 mL/min (constant flow)
- Oven Program: 40 °C (2 min) ramped to 280 °C at 10 °C/min, hold 5 min
- Transfer Line Temperature: 280 °C
- Mass Spectrometer: LECO Pegasus HT TOFMS, ion source 250 °C
- Acquisition: Full mass range 33–500 m/z at 15 spectra/s
Main Results and Discussion
All 26 regulated allergens were detected and identified using automated peak finding. Calibration curves for compounds such as geraniol exhibited excellent linearity (R² > 0.99) over four orders of magnitude. Full mass range data enabled recognition of coeluting matrix interferences that share diagnostic m/z values, which would skew quantification in a SIM‐only approach. Deconvolution algorithms isolated pure spectra of target analytes and interferences, allowing selection of unique m/z channels (e.g., m/z 123, 84 for geraniol) and accurate quantitation.
Benefits and Practical Applications
- Enhanced specificity through full mass range acquisition and deconvolution
- Automated calibration and retrospective data interrogation without reinjection
- Improved accuracy in regulated allergen quantification within complex formulations
- Streamlined compliance reporting for cosmetic and personal care manufacturers
Future Trends and Applications
Advances in high-resolution TOFMS and automated data processing will further improve detection limits and throughput. Integration with robotic sample preparation and machine-learning algorithms could enable real-time allergen monitoring and broader screening of emerging sensitizers in personal care products.
Conclusion
GC-TOFMS with full mass range acquisition on the Pegasus HT provides robust, accurate, and efficient quantification of regulated contact allergens in personal care products. The combination of high speed, sensitivity, and deconvolution ensures reliable results and supports regulatory compliance without repetitive analyses.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Rapid Screening for Contact Allergens in Perfumes with Pegasus BT GC-TOFMS
2016|Agilent Technologies|Applications
Rapid Screening for Contact Allergens in Perfumes with Pegasus® BT GC-TOFMS LECO Corporation; Saint Joseph, Michigan USA Key Words: Pegasus BT, Target Screening, Non-Target Characterization, Full m/z Range Acquisition, TOFMS, Deconvolution, Calibration, Rapid Analysis Reporting threshold à Figure 1. GC-TOFMS…
Key words
cinnamic, cinnamicbenzyl, benzylpegasus, pegasuscitral, citraltofms, tofmsallergens, allergensalcohol, alcoholcontact, contactleco, lecoyou've, you'veamylcinnamaldehyde, amylcinnamaldehydedelivering, deliveringtarget, targethexylcinnamaldehyde, hexylcinnamaldehydelyral
GC-TOFMS for Fast Targeted Allergen Screening and Non-Targeted Characterization for Personal Care Products
2016|Agilent Technologies|Posters
GC-TOFMS for Fast Targeted Allergen Screening and Non-Targeted Characterization for Personal Care Products Bernie C.L. Yeung, Elizabeth M. Humston-Fulmer, Joseph E. Binkley, Lorne M. Fell, Christina N. Kelly, and David E. Alonso | LECO Corporation, St. Joseph, MI Introduction Contact…
Key words
cinnamic, cinnamicbenzyl, benzylodor, odortargeted, targetedcitral, citraltofms, tofmsmathematically, mathematicallyallergen, allergendeconvolution, deconvolutioncoumarin, coumarinallergens, allergensalcohol, alcoholpegasus, pegasuscharacterization, characterizationscreening
LECO TruTOF HT High Throughput TOFMS Delivering the
2011|LECO|Brochures and specifications
® TruTOF HT High Throughput TOFMS ® Delivering the Right Results ® LECO’s TruTOF HT TOFMS High Throughput Time-of-Flight Mass Spectrometer The solution to your analytical challenges. The TruTOF HT TOFMS combines LECO’s benchtop Time-of-Flight Mass Spectrometer (TOFMS) with ChromaTOF®-GC…
Key words
true, truechromatof, chromatoftrutof, trutofdeconvolution, deconvolutioncaliper, calipertofms, tofmspeak, peaksignal, signalleco, lecocontinuity, continuityfind, findhrt, hrtseconds, secondsthroughput, throughputtime
Detection of Cork Taint Fault in Wine Using HS-SPME and GC-TOFMS for the Quantification of 2,4,6-trichloroanisole
2016|Agilent Technologies|Applications
Detection of Cork Taint Fault in Wine Using HS-SPME and GC-TOFMS for the Quantification of 2,4,6-trichloroanisole LECO Corporation; Saint Joseph, Michigan USA 1. Introduction Cork taint is a common fault in wine and can occur in naturally corked wines of…
Key words
pegasus, pegasusleco, lecodelivering, deliveringscience, sciencecork, corktaint, taintmass, masslife, lifemathematically, mathematicallyright, rightcoelutions, coelutionsanalyses, analysesfault, faultneeding, needingunparalleled