Automotive interior VOC and FOG emissions
Applications | 2020 | Thermo Fisher ScientificInstrumentation
In modern automotive manufacturing volatile organic compound emissions from interior materials can affect vehicle air quality safety and customer satisfaction. The VDA 278 method provides a standardized way to measure both volatile organic compounds VOCs and semi volatile fogging compounds FOGs released by car trim parts under controlled conditions. Ensuring reliable emission data is key for regulatory compliance material selection and consumer health
This technical guide aims to describe the direct thermal desorption gas chromatography mass spectrometry TD GC MS workflow for quantifying VOC and FOG emissions in accordance with the VDA 278 protocol. The study outlines sample preparation best practices instrument configuration performance checks and data integration and quantitation strategies using a combined Thermo Scientific Markes International system
The workflow uses direct desorption of test samples placed in glass tubes or Tenax TA sorbent tubes followed by two stage trap desorption and transfer to a GC column. Key steps include
Instrument performance is verified by blank runs trap fires column blanks and control standards ensuring retention time separation peak shape and recovery criteria meet VDA 278 requirements
The described method yields reproducible VOC and FOG quantitation with typical relative standard deviations below fifteen percent. The use of integrated inlet and outlet splits reduces trap overload and baseline artefacts. Incorporating air step awareness extends column and detector lifetimes. Quantitation can be performed semi quantitatively via response factors or via multi point calibration graphs. Compound identification relies on mass spectra library matching retention indices and integration of complex humps and rider peaks in Chromeleon software
Implementing the combined TD GC MS solution offers several advantages
Advancements may include
This guide provides a structured approach for VDA 278 compliant measurement of VOC and FOG emissions in automotive interior materials using direct thermal desorption GC MS. Through careful sample handling system suitability checks and optimized instrument settings the approach delivers accurate reproducible emission data. The combined Thermo Scientific Markes International TD GC MS platform simplifies adoption of the standard and supports quality control regulatory compliance and material development decisions
VDA 278 Thermal desorption analysis of organic emissions for characterization of non metallic materials for automobiles Verband der Automobilindustrie 2011
GC/MSD, Thermal desorption, GC/SQ
IndustriesMaterials Testing
ManufacturerThermo Fisher Scientific, Markes
Summary
Importance of the topic
In modern automotive manufacturing volatile organic compound emissions from interior materials can affect vehicle air quality safety and customer satisfaction. The VDA 278 method provides a standardized way to measure both volatile organic compounds VOCs and semi volatile fogging compounds FOGs released by car trim parts under controlled conditions. Ensuring reliable emission data is key for regulatory compliance material selection and consumer health
Goals and study overview
This technical guide aims to describe the direct thermal desorption gas chromatography mass spectrometry TD GC MS workflow for quantifying VOC and FOG emissions in accordance with the VDA 278 protocol. The study outlines sample preparation best practices instrument configuration performance checks and data integration and quantitation strategies using a combined Thermo Scientific Markes International system
Methodology and instrumentation
The workflow uses direct desorption of test samples placed in glass tubes or Tenax TA sorbent tubes followed by two stage trap desorption and transfer to a GC column. Key steps include
- Tube conditioning at 300 degrees C in inert gas flow to eliminate contaminants
- Sample cutting storing and loading under low VOC background conditions
- Calibration with toluene and n hexadecane standards spiked onto sorbent tubes
- Automated thermal desorption on a 100 tube autosampler with cryogen free trap focusing
- GC separation on an Ultra 2 column with VOC and FOG temperature programs and full scan MS detection
Instrument performance is verified by blank runs trap fires column blanks and control standards ensuring retention time separation peak shape and recovery criteria meet VDA 278 requirements
Key results and discussion
The described method yields reproducible VOC and FOG quantitation with typical relative standard deviations below fifteen percent. The use of integrated inlet and outlet splits reduces trap overload and baseline artefacts. Incorporating air step awareness extends column and detector lifetimes. Quantitation can be performed semi quantitatively via response factors or via multi point calibration graphs. Compound identification relies on mass spectra library matching retention indices and integration of complex humps and rider peaks in Chromeleon software
Benefits and practical applications
Implementing the combined TD GC MS solution offers several advantages
- High throughput analysis of up to one hundred samples with minimal manual intervention
- Elimination of liquid cryogen and lower operating costs with electrical cooling
- Comprehensive contamination control from sample prep to tube sealing
- Unified instrument control and reporting in Chromeleon CDS with customizable eWorkflows
- Robust quantitation and reliable material screening for automotive interior suppliers and OEMs
Future trends and possibilities
Advancements may include
- Higher sensitivity traps and mass analyzers for trace emission detection
- Automated sample preparation to reduce handling variability
- Integration of real time data analytics and machine learning for emission profiling
- Expansion of the VDA 278 method to new polymer nanocomposites and bio based materials
Conclusion
This guide provides a structured approach for VDA 278 compliant measurement of VOC and FOG emissions in automotive interior materials using direct thermal desorption GC MS. Through careful sample handling system suitability checks and optimized instrument settings the approach delivers accurate reproducible emission data. The combined Thermo Scientific Markes International TD GC MS platform simplifies adoption of the standard and supports quality control regulatory compliance and material development decisions
Reference
VDA 278 Thermal desorption analysis of organic emissions for characterization of non metallic materials for automobiles Verband der Automobilindustrie 2011
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of VOCs in automotive trim components using TD-GC-MS
2020|Thermo Fisher Scientific|Applications
APPLICATION NOTE 73527 Analysis of VOCs in automotive trim components using TD-GC-MS Authors: Klaus Schrickel1 and Jane Cooper2 Thermo Fisher Scientific, Dreieich, Germany Thermo Fisher Scientific, Runcorn, UK 1 2 Keywords: Automotive industry, automotive interior materials, vehicle interior air quality,…
Key words
fog, fogsvoc, svochexadecane, hexadecanevoc, vocpolyurethane, polyurethaneinterior, interiorcounts, countstic, ticstandard, standardsample, sampledesorption, desorptionautomotive, automotivecsvoc, csvoccvoc, cvoctemperature
Direct Desorption of Car Trim Materials for VOC and SVOC Analysis in Accordance with VDA Method 278
2017|Markes|Applications
Application Note 059 Direct Desorption of Car Trim Materials for VOC and SVOC Analysis in Accordance with VDA Method 278 Application Note Abstract In this application note, we demonstrate the suitability of Markes’ TD-100 automated thermal desorption system for performing…
Key words
hexadecane, hexadecanetrim, trimtoluene, tolueneabundance, abundancepentadecane, pentadecanevoc, voctetradecane, tetradecanedodecane, dodecanecar, careicosane, eicosanetriethylenediamine, triethylenediaminegraphitised, graphitisedtrimethylsilanol, trimethylsilanolautomotive, automotiveamount
ENSURING COMPLIANCE WITH VDA 278 REGULATIONS
2019|PerkinElmer|Technical notes
ENSURING COMPLIANCE WITH VDA 278 REGULATIONS VDA 278 Thermal Desorption Analysis of VOCs in Automobile Interiors Guide Table of Contents INTRODUCTION................................................................... 2 DEFINITIONS........................................................................... 3 Thermal Desorption Analysis.......................................................... 3 VOC Value..................................................................................... 3 Fogging Value................................................................................ 3 SAMPLING AND STORAGE............................................. 3 ANALYSIS AND…
Key words
desorption, desorptionfogging, foggingdesorber, desorbervoc, voccondensation, condensationtenax, tenaxfid, fidsubstances, substancescontrol, controlthermal, thermalparameters, parameterstube, tubeturbomatrix, turbomatrixqualitatively, qualitativelydevice
"What’s inside your car?” - Car interior emissions testing using Thermal desorption GC/MS analysis
|Thermo Fisher Scientific|Presentations
"What’s inside your car?” Car interior emissions testing using Thermal desorption GC/MS analysis Inge de Dobbeleer EU GCMS specialist ThermoFisher Lara Kelly Sales Manager Markes Thermal desorption The Thermal Desorption Process On-line Electrically-cooled focusing trap Direct desorption of materials Canisters…
Key words
genesis, genesisvoc, voccar, caremissions, emissionsdesorption, desorptionfog, fogleather, leatherthermal, thermalemission, emissiontrim, trimchamber, chambercompounds, compoundssubstances, substancestube, tubemin