FAMEs (PUFA, animal source) - MXT®-WAX
Applications | | RestekInstrumentation
The accurate separation and quantification of polyunsaturated fatty acid (PUFA) methyl esters is critical in nutritional analysis, quality control of food and feed products, and research on lipid metabolism. Reliable methods that provide baseline resolution of individual fatty acid methyl esters (FAMEs) support regulatory compliance, product development, and scientific studies.
This application note outlines a gas chromatography–flame ionization detection (GC–FID) method for profiling animal-source PUFA FAMEs. The goal is to demonstrate chromatographic conditions that achieve clear separation of 18 common PUFA methyl esters, enabling precise identification and quantification in complex matrices.
The method employs a 30 m × 0.28 mm ID MXT®-WAX capillary column with 0.25 µm film thickness.
The optimized temperature program and polar MXT-WAX phase deliver baseline resolution of all 18 FAMEs, with retention times spanning approximately 4 to 32 minutes. Key observations:
The method shows consistent peak shapes and retention reproducibility, underlining its robustness for routine laboratory use.
Advances that could enhance PUFA analysis include fast GC methods using shorter columns or higher ramp rates, coupling with mass spectrometry for structural confirmation, and automated data processing for high-throughput screening. Supercritical fluid chromatography (SFC) is also emerging as a complementary technique for lipid profiling.
The described GC–FID method on an MXT-WAX column provides reliable, high-resolution separation of 18 key animal-source PUFA methyl esters. Its simplicity, reproducibility, and compatibility with routine laboratory setups make it an effective tool for lipid analysis in research, food quality control, and regulatory environments.
No external literature references were provided in the original application note.
GC, GC columns, Consumables
IndustriesFood & Agriculture
ManufacturerRestek
Summary
Importance of the Topic
The accurate separation and quantification of polyunsaturated fatty acid (PUFA) methyl esters is critical in nutritional analysis, quality control of food and feed products, and research on lipid metabolism. Reliable methods that provide baseline resolution of individual fatty acid methyl esters (FAMEs) support regulatory compliance, product development, and scientific studies.
Aims and Overview
This application note outlines a gas chromatography–flame ionization detection (GC–FID) method for profiling animal-source PUFA FAMEs. The goal is to demonstrate chromatographic conditions that achieve clear separation of 18 common PUFA methyl esters, enabling precise identification and quantification in complex matrices.
Methodology and Instrumentation
The method employs a 30 m × 0.28 mm ID MXT®-WAX capillary column with 0.25 µm film thickness.
- Sample introduction: 0.1 µL split injection (20:1 split ratio) of a certified PUFA 2 mix.
- Oven program: initial temperature 160 °C ramped to 250 °C at 2 °C/min, with a 10-minute final hold.
- Injector and detector temperature: 260 °C.
- Carrier gas: hydrogen at a linear velocity of 40 cm/s.
- Detector: flame ionization detector (FID) sensitivity set to 8 × 10⁻¹¹ AFS.
Main Results and Discussion
The optimized temperature program and polar MXT-WAX phase deliver baseline resolution of all 18 FAMEs, with retention times spanning approximately 4 to 32 minutes. Key observations:
- Early eluters (C14:0, C16:0) appear between 4 and 8 minutes, confirming efficient desorption at 160 °C.
- Monounsaturated and diunsaturated C18 derivatives elute between 8 and 16 minutes, demonstrating good selectivity for positional and geometric isomers.
- Long-chain PUFAs such as eicosapentaenoic acid (C20:5n3) and docosahexaenoic acid (C22:6n3) elute after 20 minutes with sharp, symmetric peaks.
The method shows consistent peak shapes and retention reproducibility, underlining its robustness for routine laboratory use.
Benefits and Practical Applications
- Comprehensive profiling of animal-derived PUFA FAMEs for nutritional labeling and quality assurance.
- Rapid analysis with complete separation in under 35 minutes, improving laboratory throughput.
- Compatibility with standard GC–FID instrumentation and minimal method development required.
Future Trends and Potential Applications
Advances that could enhance PUFA analysis include fast GC methods using shorter columns or higher ramp rates, coupling with mass spectrometry for structural confirmation, and automated data processing for high-throughput screening. Supercritical fluid chromatography (SFC) is also emerging as a complementary technique for lipid profiling.
Conclusion
The described GC–FID method on an MXT-WAX column provides reliable, high-resolution separation of 18 key animal-source PUFA methyl esters. Its simplicity, reproducibility, and compatibility with routine laboratory setups make it an effective tool for lipid analysis in research, food quality control, and regulatory environments.
References
No external literature references were provided in the original application note.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
FAMEs PUFA (marine source) - MXT®-WAX
|Restek|Applications
FAMEs PUFA (marine source) MXT®-WAX 1 1. C14:0 2. C16:0 3. C16:1n7 4. C18:0 5. C18:1n9 6. C18:1n7 7. C18:1n5 8. C18:2n6 9. C18:3n3 10. C18:4n3 11. C20:1n11 12. C20:1n9 13. C20:1n7 14. C20:2n6 15. C20:3n6 16. C20:4n6 17. C20:3n3…
Key words
mxt, mxtpufa, pufamarine, marinefames, fameswax, waxhydrogen, hydrogensplit, splitsource, sourceinjection
FAMEs PUFA (menhaden source) - FAMEWAX™
|Restek|Applications
FAMEs PUFA (menhaden source) FAMEWAX™ 3 1 (split injection) 8 2 26 9 30 5 16 4 7 6 19 10 11 15 25 20 14 23 17 12 22 18 21 24 35 27 28 29 31 32 33…
Key words
menhaden, menhadenfamewax, famewaxpufa, pufafames, fameshelium, heliumsplit, splitsource, sourceinjection
Highly Reproducible Capillary GC Analyses of Polyunsaturated FAMEs Using a Guaranteed Performance SPB™-PUFA Column
1996|Merck|Applications
Application Note 80 Highly Reproducible Capillary GC Analyses of Polyunsaturated FAMEs Using a Guaranteed Performance SPB™-PUFA Column Figure A. The SPB-PUFA capillary column is designed for the reproducible analysis of fatty acid methyl esters. It complements the more polar polyethylene…
Key words
pufa, pufaspb, spbcapillary, capillaryester, esterpolyunsaturated, polyunsaturatedmix, mixfames, famesacid, acidisomer, isomercolumn, columnmethyl, methylpolyalkylene, polyalkyleneatherosclerosis, atherosclerosismenhaden, menhadenfatty
FAMEs (Polyunsaturated Fatty Acids, Animal Source) on Rt-2330
|Restek|Applications
FAMEs (Polyunsaturated Fatty Acids, Animal Source) on Rt-2330 4 5 2 11 7 15 9 6 13 Peaks 1. C14:0 2. C16:0 3. C16:1n7 4. C18:0 5. C18:1n9 6. C18:1n7 7. C18:2n6 8. C18:3n6 9. C18:3n3 10. C20:3n6 11. C20:4n6…
Key words
notes, notesoven, ovenpeaks, peakscarrier, carrierdetector, detectorinjection, injectionmin, mingas, gascolumn, columntime, timesample