TO-15 65 Component Mix on Rxi®-1ms (30 m)

Applications |  | RestekInstrumentation
GC/MSD, Thermal desorption, GC/SQ, GC columns, Consumables
Industries
Environmental
Manufacturer
Agilent Technologies, Restek, Nutech

Summary

Importance of the Topic


Volatile organic compounds are critical environmental and industrial analytes. Reliable detection and quantification of a broad mix of VOCs at low concentrations support regulatory compliance, indoor air quality assessment, and process monitoring.

Objectives and Study Overview


This work evaluates the performance of the Rxi-1ms GC column combined with cryogenic preconcentration for the separation and identification of sixty‐five target VOCs. The aim is to demonstrate rapid, high-resolution analysis suitable for TO-15 applications.

Methodology and Instrumentation


The following configuration was used:
  • Column: Rxi-1ms, 30 m × 0.32 mm ID, 1 µm film thickness
  • Preconcentrator: Nutech 8900DS cryofocusing at –160 °C
  • Trap materials: Glass beads (Trap 1) and Tenax (Trap 2)
  • GC Conditions: Oven 35 °C (1 min), ramp to 230 °C at 11 °C/min; helium carrier at 2.0 mL/min
  • Injection: Direct, 250 cc sample at 10 ppbv, desorb at 190 °C for 30 s
  • MS Detection: HP 5973 quadrupole, EI mode, scan 35–250 amu at 3.32 scans/s

Main Results and Discussion


All sixty-five compounds eluted between 1.37 and 12.38 minutes with baseline separation for the majority of analytes. Early eluters such as propylene and Freon® 12 are resolved within 1.4 minutes, while heavier aromatics and chlorinated species appear after 6 minutes. Two coelutions of minor concern share an ion but are resolved by unique qualifier ions. The fast ramp and optimized film thickness deliver a total run time under 13 minutes without sacrificing peak shape or resolution.

Benefits and Practical Applications


Key advantages include:
  • High throughput analysis for regulatory VOC panels
  • Robust separation across a wide volatility range
  • Enhanced sensitivity from cryogenic preconcentration
  • Compatibility with standard TO-15 sampling protocols

Future Trends and Opportunities


Advances may involve integrating two-dimensional GC or high-resolution MS for even greater compound discrimination. Development of automated sampling systems and miniaturized preconcentrators will further streamline field and laboratory workflows.

Conclusion


The Rxi-1ms column coupled with cryofocusing and quadrupole MS provides a rapid, sensitive, and reproducible method for comprehensive VOC analysis. The approach meets TO-15 requirements and supports diverse environmental and industrial applications.

References


  • Restek Corporation Application Note 34436: TO-15 65 Component Mix on Rxi-1ms, 30 m column

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
TO-15 65 Component Mix on Rxi®-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi®-624Sil MS (30 m)
|Agilent Technologies|Applications
TO-15 65 Component Mix on Rxi®-624Sil MS (30 m) 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. tR (min) 1.42 1.46 1.58 1.62 1.73…
Key words
xylene, xylenechloride, chloridevinyl, vinylpeaks, peaksnutech, nutechcryofocuser, cryofocusermin, mindisulfide, disulfideacetate, acetatepreconcentrator, preconcentratormethyl, methylcarbon, carbonacrolein, acroleinbfb, bfbstandard
TO-15 65 Component Mix on Rxi®-5Sil MS (30 m, 1.5 mL/min)
TO-15 65 Component Mix on Rxi®-5Sil MS (30 m, 1.5 mL/min) 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Peaks Propylene Dichlorodifluoromethane (Freon® 12) Chloromethane 1,2-Dichlorotetrafluoroethane (Freon® 114)…
Key words
xylene, xylenechloride, chloridevinyl, vinylpeaks, peaksnutech, nutechcryofocuser, cryofocuserdisulfide, disulfideacetate, acetatepreconcentrator, preconcentratormethyl, methylcarbon, carbonacrolein, acroleinbfb, bfbmin, minchloroethane
TO-15 65 Component Mix on Rtx®-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx®-VMS (30 m, 2.0 mL/min) 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Peaks Propylene Dichlorodifluoromethane (Freon® 12) 1,2-Dichlorotetrafluoroethane (Freon® 114) Chloromethane Vinyl…
Key words
xylene, xylenechloride, chloridemin, minvinyl, vinylcontaminant, contaminantscan, scanpeaks, peaksnutech, nutechcryofocuser, cryofocuserdisulfide, disulfideacetate, acetatepreconcentrator, preconcentratormethyl, methylcarbon, carbonacrolein
TO-15 65 Component Mix on Rtx®-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx®-VMS (30 m, 1.2 mL/min) 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Peaks Propylene Dichlorodifluoromethane (Freon® 12) 1,2-Dichlorotetrafluoroethane (Freon® 114) Chloromethane Vinyl…
Key words
xylene, xylenechloride, chloridemin, minvinyl, vinylcontaminant, contaminantscan, scanpeaks, peaksnutech, nutechcryofocuser, cryofocuserdisulfide, disulfideacetate, acetatepreconcentrator, preconcentratormethyl, methylcarbon, carbonacrolein