SICRIT® Plug & Play Soft Ionization
Technical notes | 2018 | PlasmionInstrumentation
Soft ionization approaches that separate sample introduction from ion generation are transforming mass spectrometry. By minimizing in-source fragmentation and transfer losses, they improve sensitivity, selectivity and throughput. The SICRIT® method exemplifies this advance, enabling real-time detection of volatile and semi-volatile compounds in diverse fields from quality control to environmental monitoring.
This article presents the principles, instrumentation, performance and application scope of SICRIT® (Soft Ionization by Chemical Reaction in Transfer), a patented flow-through cold-plasma ionization source. It aims to demonstrate how SICRIT® integrates with existing mass spectrometers and chromatographic interfaces, and to summarize key analytical results and use cases.
The core of SICRIT® is a capillary-confined cold plasma that generates reagent ions downstream of the sample inlet. Analytes are drawn through the plasma before entering the MS, reducing charge repulsion and neutralization losses typical in conventional sources. The system comprises:
No special sample preparation or ionization tuning is required. The plug-and-play design supports LC, GC and direct headspace analysis.
Performance evaluations demonstrated sub-ppt detection limits for pesticides, illicit drugs and aroma compounds. Key findings include:
These results confirm enhanced sensitivity, broadened analyte coverage (primarily MH+ species) and rapid response suitable for reaction monitoring and contamination screening.
SICRIT® offers multiple advantages:
Users can convert standard mass spectrometers into highly sensitive electronic noses or hybrid analytical platforms.
Emerging directions for SICRIT® include:
As data-driven analytics and machine learning expand, SICRIT®’s real-time profiling capabilities will gain further relevance.
SICRIT® technology represents a significant leap in soft ionization mass spectrometry. By decoupling ion generation from sample delivery, it achieves superior sensitivity, broader analyte coverage and flexible coupling to chromatography and sampling modules. Its plug-and-play design and sub-ppt detection levels open new analytical possibilities across research, industry and regulatory sectors.
GC/MSD, LC/MS
IndustriesManufacturerPlasmion
Summary
Importance of the Topic
Soft ionization approaches that separate sample introduction from ion generation are transforming mass spectrometry. By minimizing in-source fragmentation and transfer losses, they improve sensitivity, selectivity and throughput. The SICRIT® method exemplifies this advance, enabling real-time detection of volatile and semi-volatile compounds in diverse fields from quality control to environmental monitoring.
Objectives and Overview of the Article
This article presents the principles, instrumentation, performance and application scope of SICRIT® (Soft Ionization by Chemical Reaction in Transfer), a patented flow-through cold-plasma ionization source. It aims to demonstrate how SICRIT® integrates with existing mass spectrometers and chromatographic interfaces, and to summarize key analytical results and use cases.
Methodology and Instrumentation
The core of SICRIT® is a capillary-confined cold plasma that generates reagent ions downstream of the sample inlet. Analytes are drawn through the plasma before entering the MS, reducing charge repulsion and neutralization losses typical in conventional sources. The system comprises:
- SICRIT® SC-20X ionization set with control unit and ion source
- Interfaces for major LC-MS platforms (Thermo, Agilent, Sciex; others on request)
- Optional GC/SPME module for direct coupling with gas chromatography or SPME fibers
No special sample preparation or ionization tuning is required. The plug-and-play design supports LC, GC and direct headspace analysis.
Main Results and Discussion
Performance evaluations demonstrated sub-ppt detection limits for pesticides, illicit drugs and aroma compounds. Key findings include:
- Online screening of >300 coffee bean volatiles in under one second
- GC-soft-ionization-MS analysis of 28 pesticides in water with LODs down to 30 pg/mL
- Direct SPME-MS detection of drugs at 0.3 pg/mL without chromatographic separation
These results confirm enhanced sensitivity, broadened analyte coverage (primarily MH+ species) and rapid response suitable for reaction monitoring and contamination screening.
Benefits and Practical Applications
SICRIT® offers multiple advantages:
- Seamless integration with existing MS instruments
- Compatibility with LC, GC, SPME and direct-scan workflows
- Ultrasensitive detection without complex tuning or prep
- Expanded analytical freedom for quality control, food safety, forensics, emission monitoring and more
Users can convert standard mass spectrometers into highly sensitive electronic noses or hybrid analytical platforms.
Future Trends and Potential Applications
Emerging directions for SICRIT® include:
- Automated high-throughput screening in industrial quality control
- On-site environmental and emissions monitoring with portable or hybrid systems
- Integration with microfluidics and reaction-bioprocess monitoring
- Advanced non-targeted analysis leveraging soft ionization for unknowns discovery
As data-driven analytics and machine learning expand, SICRIT®’s real-time profiling capabilities will gain further relevance.
Conclusion
SICRIT® technology represents a significant leap in soft ionization mass spectrometry. By decoupling ion generation from sample delivery, it achieves superior sensitivity, broader analyte coverage and flexible coupling to chromatography and sampling modules. Its plug-and-play design and sub-ppt detection levels open new analytical possibilities across research, industry and regulatory sectors.
Reference
- Pesticide GC-MS analysis using SICRIT®, Analyst 2017, 142, 1909.
- SPME-MS drug screening with SICRIT®, Anal. Chem. 2016, 88, 7252.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Direct MS Screening
2020|Plasmion|Presentations
Plasmion GmbH Am Mittleren Moos 48, 86167 Augsburg Tel.: +49 821 2071 3355 Mail: [email protected] Web: www.plasmion.de Dr. Jan-Christoph Wolf Direct MS Screening Get results faster with SICRIT® 04.05.2020 Technology The patented flow-through geometry of the SICRIT® ionization source is…
Key words
sicrit, sicritscreening, screeningquantification, quantificationcoupling, couplingpfca, pfcaionization, ionizationwithout, withoutdirect, directenables, enablesaroma, aromaabundance, abundancelike, likecompounds, compoundsexplosives, explosivesleather
Coffee Aroma Profiling - Direct SICRIT® HR-MS Analysis
2019|Thermo Fisher Scientific|Applications
Application Note Coffee Aroma Profiling - Direct SICRIT® HR-MS Analysis Introduction Coffee is one of the most popular beverages and known for its manifold aroma profiles. Aroma is one of the first senses experienced when preparing or consuming a coffee…
Key words
sicrit, sicritcoffee, coffeeprofiling, profilingroasting, roastingdirect, directaroma, aromabean, beanbeans, beansreal, realvocs, vocsroasted, roastedvolatile, volatileidentified, identifiedreserved, reservedinterfacing
Plasmion SICRIT® Ionization Set SC-30
2020|Plasmion|Brochures and specifications
Product Note SICRIT® Ionization Set SC-30 The SICRIT® Ionization Set SC-30 upgrades any LC-MS instrument with a plug & play ionization source. The SICRIT® soft ionization technology enables PTR-like online MS-measurements as well as coupling of sample enrichment and/or chromatographic…
Key words
sicrit, sicritsoft, softsource, sourceion, ionplasmion‘s, plasmion‘sionization, ionizationinterfaces, interfacesspme, spmemeasurements, measurementsreserved, reserveddirect, directrights, rightsyour, yourplasma, plasmaoperation
Soft Ionization GC Coupling to LC-MS Systems
2021|Plasmion|Brochures and specifications
Soft Ionization GC Coupling to LC-MS Systems Combine the best of both worlds – all advantages from GC and LC-MS in an integrated solution A Powerful Combination Instead of Separate Solutions GC-MS is the method of choice for many challenges…
Key words
sicrit, sicritcoupling, couplingionization, ionizationplasmion‘s, plasmion‘ssoft, softenables, enablessource, sourcespme, spmepal, palheated, heatedplasmion, plasmiondiazinone, diazinoneconnection, connectioncold, coldrtc