GC Column Selection Guide
Guides | 2013 | MerckInstrumentation
Effective selection of a capillary GC column underpins sensitivity, resolution and robustness in gas chromatography applications. Understanding how stationary phase chemistry, column internal diameter, film thickness and length interact to shape retention and peak quality is essential for environmental monitoring, industrial hygiene, petrochemical profiling, food and beverage testing, pharmaceuticals and forensic analyses.
This guide reviews the evolution of capillary column technology at Supelco, summarises selection criteria and presents convenient industry- and application-based phase selection charts. It explains the principles governing analyte-phase interactions, and offers practical steps to optimise method performance from volatile organics to high-boiling semivolatiles and chiral separations.
The guide develops a four-step column selection protocol:
The guide also introduces phase ratio (β) to compare columns with similar retention behaviour. Extensive phase specifications and temperature limits are tabulated, and industry-specific chromatographic phase selection maps are provided.
The guide demonstrates:
Industry application charts align EPA, NIOSH, USP and ASTM methods with recommended columns, streamlining phase choice for environmental, petrochemical, biofuel, agricultural, food and clinical laboratories.
Applying these guidelines enables analysts to:
The guide points to several advancing areas:
Strategic column selection is the cornerstone of successful GC analyses. By systematically evaluating phase chemistry, bore size, film thickness and length, and by referring to industry-specific charts, analysts can optimise separations for sensitivity, speed and reproducibility. Ongoing phase innovations—especially in ionic liquids and chiral selectors—promise further gains in selectivity, throughput and method flexibility.
GC columns, Consumables
IndustriesManufacturerMerck
Summary
Importance of the Topic
Effective selection of a capillary GC column underpins sensitivity, resolution and robustness in gas chromatography applications. Understanding how stationary phase chemistry, column internal diameter, film thickness and length interact to shape retention and peak quality is essential for environmental monitoring, industrial hygiene, petrochemical profiling, food and beverage testing, pharmaceuticals and forensic analyses.
Aims and Study Overview
This guide reviews the evolution of capillary column technology at Supelco, summarises selection criteria and presents convenient industry- and application-based phase selection charts. It explains the principles governing analyte-phase interactions, and offers practical steps to optimise method performance from volatile organics to high-boiling semivolatiles and chiral separations.
Methodology and Instrumentation
The guide develops a four-step column selection protocol:
- Stationary phase: match polarity (phase chemistry) to analyte class by “like dissolves like” and consult established application charts.
- Column internal diameter: balance efficiency (narrow I.D.) vs. sample capacity (wide bore) to prevent overload or loss of resolution.
- Film thickness: choose thin films (<0.25 µm) to sharpen peaks, reduce bleed and raise maximum temperature for high-boiling compounds; select thicker films to boost capacity for trace analytes.
- Column length: standard 30 m columns compromise resolution and analysis time; longer columns increase separation but add backpressure, whereas shorter columns speed screening.
The guide also introduces phase ratio (β) to compare columns with similar retention behaviour. Extensive phase specifications and temperature limits are tabulated, and industry-specific chromatographic phase selection maps are provided.
Main Results and Discussion
The guide demonstrates:
- Non-polar phases (e.g., dimethyl siloxane, SPB-1, SLB-5ms) suit alkanes and generic screening, while intermediate polar and polar phases (e.g., cyanopropyl, poly(ethylene glycol)) enable selective separation of alcohols, acids, esters, FAMEs and herbicides.
- Highly polar and ionic liquid columns (e.g., SLB-IL59, SLB-IL100, TCEP) deliver novel selectivities for aromatic hydrocarbons, oxygenates and GC×GC modulation.
- Chiral cyclodextrin-based phases (Astec CHIRALDEX®, DEX™ 120 series) resolve enantiomers of pharmaceuticals, flavors and environmental contaminants.
- PLOT columns (Carboxen®, Supel-Q™, alumina and molecular sieve) provide high-throughput separations of permanent gases, light hydrocarbons and volatiles by headspace or purge-and-trap.
Industry application charts align EPA, NIOSH, USP and ASTM methods with recommended columns, streamlining phase choice for environmental, petrochemical, biofuel, agricultural, food and clinical laboratories.
Benefits and Practical Applications
Applying these guidelines enables analysts to:
- Achieve baseline resolution of critical pairs across a wide volatility and polarity range.
- Reduce method development time by leveraging established phase selection charts.
- Minimise column bleed and enhance detector compatibility (FID, ECD, MS, FPD) through bonded and crosslinked phases.
- Adapt to emerging analyses (e.g., biodiesel FAME profiling, chiral drug screening, GC×GC workflows) using ionic liquid and specialty phases.
Future Trends and Opportunities
The guide points to several advancing areas:
- Expansion of ionic liquid and third-generation phases offering orthogonal selectivity and elevated thermal stability for novel analyte classes and GC×GC architectures.
- Integration of micro- and fast-GC formats with ultranarrow bore, high-β columns to boost throughput without sacrificing resolution.
- Development of tailor-made coatings and hybrid columns combining PLOT, chiral and bonded phases for complex matrices.
- Linking advanced column chemistries to automated method development and machine-learning tools for rapid optimization.
Conclusion
Strategic column selection is the cornerstone of successful GC analyses. By systematically evaluating phase chemistry, bore size, film thickness and length, and by referring to industry-specific charts, analysts can optimise separations for sensitivity, speed and reproducibility. Ongoing phase innovations—especially in ionic liquids and chiral selectors—promise further gains in selectivity, throughput and method flexibility.
Reference
- McNair H.M., Miller J.M. Basic Gas Chromatography. Wiley, 1997.
- Grant D. Capillary Gas Chromatography. Wiley, 1996.
- Rood D. A Practical Guide to the Care, Maintenance, and Troubleshooting of Capillary Gas Chromatographic Systems. Hüthig, 1991.
- Grob K. Split and Splitless Injection in Capillary GC. Hüthig, 1993.
- Pawliszyn J. Solid Phase Microextraction: Theory and Practice. Wiley-VCH, 1997.
- McMaster M., McMaster C. GC/MS: A Practical User’s Guide. Wiley-VCH, 1998.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
GC Column Selection Guide - Ensuring Optimal Method Performance
2020|Merck|Brochures and specifications
GC Column Selection Guide Ensuring Optimal Method Performance The life science business of Merck operates as MilliporeSigma in the U.S. and Canada. Supelco® GC Capillary Columns There from the beginning - Manufacturing reliable and reproducible capillary columns for over 50…
Key words
programmed, programmedndicated, ndicatedcolumns, columnschiraldex, chiraldexvocol, vocolpolar, polarintuvo, intuvospb, spbphases, phasesplot, plotcolumn, columnscot, scotformat, formatchiral, chiralslb
Supelco Capillary GC Columns
2001|Merck|Technical notes
Bulletin 875C Supelco Capillary GC Columns Chemical structures, polarities, operating temperature ranges, and chemical compatibilities of Supelco™ generalpurpose capillary GC columns and columns for specific clinical, environmental, food/beverage, and petroleum/ chemical applications are summarized in this bulletin. This information should…
Key words
beta, betalength, lengthsupelco, supelcocolumn, columnphase, phasecapillary, capillarydescription, descriptioncolumns, columnsstationary, stationarymix, mixtest, testfused, fusedpolarity, polaritymixes, mixesvaporized
Supelco Capillary GC Columns
1999|Merck|Technical notes
Bulletin 875C Supelco Capillary GC Columns Chemical structures, polarities, operating temperature ranges, and chemical compatibilities of Supelco™ generalpurpose capillary GC columns and columns for specific clinical, environmental, food/beverage, and petroleum/ chemical applications are summarized in this bulletin. This information should…
Key words
beta, betalength, lengthsupelco, supelcocolumn, columnphase, phasecolumns, columnscapillary, capillarystationary, stationarydescription, descriptionfilm, filmfused, fusedtest, testmix, mixpolarity, polaritymixes
Fast GC - Increase GC Speed Without Sacrificing Resolution
2015|Merck|Brochures and specifications
Fast GC Increase GC Speed Without Sacrificing Resolution Increase Productivity Utilize Resources More Effectively Achieve Quicker Turn-Around Times Analyze More Samples Fast GC | Increase GC Speed Without Sacrificing Resolution Overview Shorter analysis times allow increased sample throughput, which translates…
Key words
sacrificing, sacrificingfast, fasttrifluoromethylsulfonyl, trifluoromethylsulfonylmin, minincrease, increaseimide, imidebenzo, benzophthalate, phthalateresolution, resolutionfluoranthene, fluoranthenespeed, speedlimonene, limonenebhc, bhcbis, bisneral