Solvents - Analysis of water in acetone
Applications | 2011 | Agilent TechnologiesInstrumentation
GC, GC columns, Consumables
IndustriesEnergy & Chemicals
ManufacturerAgilent Technologies
Key wordsSimilar PDF
Solvents
2011|Agilent Technologies|Applications
Solvents Application Note Materials Testing & Research Authors Introduction Agilent Technologies, Inc. Gas chromatography using an Agilent PoraPLOT Q-HT column separates four impurities in ethanol in five minutes. Conditions Technique : GC-wide-bore Column : Agilent PoraPLOT Q-HT, 0.53 mm x…
Key words
poraplot, poraplotacetaldehyde, acetaldehydeseparates, separatesguarantees, guaranteesinertness, inertnessacetone, acetoneethanol, ethanolgas, gasprinted, printedcolumn, columninjector, injectorsolvents, solventsfour, fourmethanol, methanolresearch
Volatile organic components - Separation of volatile organic components in whole air
2011|Agilent Technologies|Applications
Volatile organic components Separation of volatile organic components in whole air Application Note Environmental Authors Introduction Agilent Technologies, Inc. In the framework of an environmental study, the anthropogenic and biogenic contribution of organic material in air samples was determined. For…
Key words
volatile, volatileisopentane, isopentaneorganic, organiccomponents, componentsethane, ethanecourtesy, courtesywhole, wholeprinted, printedair, airinjector, injectorusa, usasize, sizeauthors, authorsenvironmental, environmentaltechnique
Hydrocarbons, C1 – C4
2011|Agilent Technologies|Applications
Hydrocarbons, C1 – C4 Application Note Energy & Fuels Authors Introduction Agilent Technologies, Inc. Gas chromatography using an Agilent PoraPLOT Q-HT column separates nine C1 to C4 hydrocarbons in 12 minutes. PoraPLOT Q-HT is not sensitive for moisture; retention times…
Key words
methylacetylene, methylacetylenepropyne, propynepropadiene, propadieneporaplot, poraplotacetylene, acetyleneethane, ethanepropane, propanepropylene, propylenefuels, fuelsmoisture, moisturemethane, methaneethylene, ethyleneprinted, printedinjector, injectorenergy
Hydrocarbons, C1 – C6 - Trace analysis of acetaldehyde in hydrocarbon: ‘symmetry of acetaldehyde peak’
2011|Agilent Technologies|Applications
Hydrocarbons, C1 – C6 Trace analysis of acetaldehyde in hydrocarbon: ‘symmetry of acetaldehyde peak’ Application Note Materials Testing & Research Authors Introduction Agilent Technologies, Inc. Gas chromatography using an Agilent PoraPLOT Q-HT column is used for the trace analysis of…
Key words
acetaldehyde, acetaldehydeporaplot, poraplottrace, tracebutane, butaneethane, ethanepropane, propanepentane, pentanemethane, methanehexane, hexanepeak, peakgas, gasprinted, printedcolumn, columninjector, injectorresearch