GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Solvents - Separation of glycols

Applications | 2011 | Agilent TechnologiesInstrumentation
GC, GC columns, Consumables
Industries
Other
Manufacturer
Agilent Technologies

Summary

Importance of the Topic


Chromatographic separation of glycols is critical for ensuring solvent purity, monitoring environmental contaminants, and supporting quality control in industrial and research laboratories. Due to their similar chemical structures and boiling points, glycols present separation challenges that demand specialized stationary phases and optimized temperature programs.

Objectives and Study Overview


  • Demonstrate rapid separation of a twelve-component glycol mixture in under 11 minutes using gas chromatography
  • Evaluate the separation performance of the Agilent CP-Select 624 CB capillary column
  • Assess the method’s resolution, reproducibility, and suitability for routine analysis

Methodology


A wide-bore gas chromatography technique was employed, utilizing a temperature gradient from 50°C to 200°C at 10°C per minute and direct sample injection of 0.02 µL.

Instrumentation


  • Gas chromatograph equipped with a nitrogen carrier gas flow of 10 mL/min
  • Agilent CP-Select 624 CB fused silica WCOT column (30 m × 0.53 mm, df = 3.0 µm; part no. CP7416)
  • Injector temperature set to 250°C for direct injection
  • Flame ionization detector operated at 250°C

Main Results and Discussion


The method achieved baseline separation of twelve glycol compounds in approximately 11 minutes. The selectivity of the CP-Select 624 CB stationary phase enabled clear resolution of structural isomers, with critical peaks showing resolution factors greater than 1.5. The elution order ranged from low molecular weight dimethyl glycol through various mono- and diglycol isomers to butyl diglycol. Peak shapes were consistently sharp, indicating excellent column performance and method robustness.

Benefits and Practical Applications of the Method


  • High-throughput analysis capability supports efficient QA/QC workflows
  • Reliable impurity profiling and solvent purity assessment for chemical manufacturing
  • Application to environmental monitoring of glycol-based pollutants
  • Potential extension to other polar solvents and similar compound classes

Future Trends and Potential Applications


  • Integration with mass spectrometric detection for improved compound identification
  • Development of miniaturized GC systems for in-field analysis
  • Advancements in stationary phase chemistries to broaden analyte scope
  • Automation and advanced data analytics for expedited method optimization

Conclusion


The combination of the Agilent CP-Select 624 CB column and an optimized temperature program provides a fast, reliable, and reproducible method for glycol separation. This approach enhances laboratory throughput, ensures accurate solvent analysis, and can be adapted for diverse analytical applications.

References


  • Agilent Technologies, Inc. Application Note A01416, October 2011

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Solvents - Separation of solvent acetate esters
Solvents - Separation of solvent acetate esters
2017|Agilent Technologies|Applications
Solvents Separation of solvent acetate esters Application Note Materials Testing & Research Authors Introduction Agilent Technologies, Inc. Gas chromatography with an Agilent CP-Select 624 CB column separates 18 solvent acetate esters in 20 minutes Conditions Peak identification Technique : GC-wide-bore…
Key words
solvent, solventesters, estersacetate, acetateprinted, printedinjector, injectorsolvents, solventsresearch, researchusa, usatesting, testingauthors, authorssize, sizetechnique, techniquesample, samplecarrier, carriermaterials
Solvents - Separation of glycols and diols
Solvents - Separation of glycols and diols
2011|Agilent Technologies|Applications
Solvents Separation of glycols and diols Application Note Materials Testing & Research Authors Introduction Agilent Technologies, Inc. Gas chromatography with an Agilent CP-Select 624 CB column separates 13 glycols and diols in less than 20 minutes. The unique selectivity of…
Key words
diols, diolsglycols, glycolsprinted, printedinjector, injectorsolvents, solventsresearch, researchusa, usatesting, testingauthors, authorssize, sizetechnique, techniquesample, samplecarrier, carriermaterials, materialsidentification
Solvents
Solvents
2011|Agilent Technologies|Applications
Solvents Application Note Materials Testing & Research Authors Introduction Agilent Technologies, Inc. For the separation of solvents the Agilent CP-Select 624 CB offers an unique high selectivity. Complex separations of volatile compounds can be achieved in the shortest possible analysis…
Key words
courtesy, courtesyprinted, printedinjector, injectorsolvents, solventsresearch, researchusa, usatesting, testingauthors, authorssize, sizetechnique, techniquesample, samplecarrier, carrieridentification, identificationmaterials, materialssolvent
Solvents - Separation of alcohols
Solvents - Separation of alcohols
2011|Agilent Technologies|Applications
Solvents Separation of alcohols Application Note Materials Testing & Research Authors Introduction Agilent Technologies, Inc. Gas chromatography with an Agilent CP-Select 624 CB column separates 12 alcohols in ten minutes. The unique selectivity of the CP-Select 624 CB stationary phase…
Key words
alcohols, alcoholsprinted, printedinjector, injectorsolvents, solventsresearch, researchusa, usatesting, testingauthors, authorssize, sizetechnique, techniquesample, samplecarrier, carriermaterials, materialsidentification, identificationsolvent
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike