Steroids - Analysis of androgen hormones as partial silyl derivatives
Applications | 2011 | Agilent TechnologiesInstrumentation
Androgen hormones play a central role in clinical diagnostics, endocrinology research and therapeutic monitoring. Reliable separation and quantification of these steroids are essential for accurate assessment of endocrine disorders, doping control and pharmaceutical development.
This study demonstrates a robust gas chromatographic method for the analysis of 26 androgen hormones converted into partial silyl derivatives. Using an Agilent CP-Sil 5 CB column, the procedure achieves complete separation of structurally similar steroids within 150 minutes, enabling comprehensive profiling in clinical research settings.
The sample preparation involved partial silylation of each steroid to enhance volatility and stability. Key chromatographic conditions included:
The analysis was performed on an Agilent gas chromatograph equipped with:
The method achieved baseline separation of all 26 androgen derivatives, including isobaric and stereoisomeric pairs such as 5α- and 5β-androstane diols and androstenediols. Key observations:
This GC-FID method offers:
Emerging directions include:
The described GC method using partial silyl derivatives and an Agilent CP-Sil 5 CB column provides a reliable, high-resolution platform for androgen analysis. It meets the demands of clinical research and routine laboratory environments by delivering precise, reproducible results within a practical timeframe.
GC, GC columns, Consumables
IndustriesClinical Research
ManufacturerAgilent Technologies
Summary
Significance of Topic
Androgen hormones play a central role in clinical diagnostics, endocrinology research and therapeutic monitoring. Reliable separation and quantification of these steroids are essential for accurate assessment of endocrine disorders, doping control and pharmaceutical development.
Objectives and Overview
This study demonstrates a robust gas chromatographic method for the analysis of 26 androgen hormones converted into partial silyl derivatives. Using an Agilent CP-Sil 5 CB column, the procedure achieves complete separation of structurally similar steroids within 150 minutes, enabling comprehensive profiling in clinical research settings.
Methodology
The sample preparation involved partial silylation of each steroid to enhance volatility and stability. Key chromatographic conditions included:
- Column: Agilent CP-Sil 5 CB, 0.32 mm × 25 m, df = 1.2 µm
- Temperature program: 210 °C hold 30 min → ramp to 235 °C at 0.25 °C/min → ramp to 280 °C at 5 °C/min, hold 10 min
- Carrier gas: Hydrogen at 80 kPa (0.8 bar)
- Injection: Solid phase injector, 2 µL sample in ethyl acetate
- Detector: Flame ionization detector at 300 °C
- Quantitation: 10 ng of each steroid standard
Used Instrumentation
The analysis was performed on an Agilent gas chromatograph equipped with:
- CP-Sil 5 CB fused silica capillary column (Part no. CP7760)
- Solid phase injector for reliable sample introduction
- Flame ionization detector (FID) for sensitive steroid detection
Main Results and Discussion
The method achieved baseline separation of all 26 androgen derivatives, including isobaric and stereoisomeric pairs such as 5α- and 5β-androstane diols and androstenediols. Key observations:
- Distinct retention profiles allowed unambiguous peak identification of testosterone, dihydrotestosterone, androsterone and related metabolites.
- Partial silylation improved chromatographic peak shape and reproducibility.
- Quantitative linearity was maintained at the 10 ng level for each analyte, ensuring accurate trace-level detection.
Benefits and Practical Applications
This GC-FID method offers:
- Comprehensive steroid profiling in a single run, reducing analysis time and labor.
- High resolution of closely eluting isomers, critical for clinical and anti-doping laboratories.
- Robust performance suitable for routine QA/QC and research workflows.
Future Trends and Potential Applications
Emerging directions include:
- Integration with mass spectrometric detection for enhanced specificity and structural confirmation.
- Automation and high-throughput platforms for large-scale clinical studies.
- Ultra-fast GC and microcolumn technologies to reduce analysis time further.
- Data-driven approaches leveraging chemometrics and machine learning for pattern recognition in steroid profiles.
Conclusion
The described GC method using partial silyl derivatives and an Agilent CP-Sil 5 CB column provides a reliable, high-resolution platform for androgen analysis. It meets the demands of clinical research and routine laboratory environments by delivering precise, reproducible results within a practical timeframe.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Fast and Comprehensive Doping Agent Screening in Urine by Triple Quadrupole GC/MS
2011|Agilent Technologies|Applications
Fast and Comprehensive Doping Agent Screening in Urine by Triple Quadrupole GC/MS Application Note Forensic Toxicology Authors Abstract Peter van Eenoo, Wim Van Gansbeke Nik De Brabanter, Koen Deventer A rapid analytical method was developed on the Agilent 7000 Series…
Key words
excr, excrmrpl, mrplandrosterone, androsteronetransitions, transitionsprohibited, prohibitedparent, parentsubstances, substancesetiocholanolone, etiocholanolonedoping, dopingtms, tmssubstance, substancewada, wadamethod, methodcollision, collisionendogenous
Introducing Semi-Automated GC/Q-TOF Screening with the AssayMAP Bravo Sample Prep Platform for Antidoping Control
2023|Agilent Technologies|Applications
Application Note Forensics and Toxicology Introducing Semi-Automated GC/Q-TOF Screening with the AssayMAP Bravo Sample Prep Platform for Antidoping Control Authors Wim Van Gansbeke, Aðalheiður Dóra Albertsdóttir, Michaël Polet, and Peter Van Eenoo DoCoLab, Ghent University, Ghent, Belgium Sofia Nieto Agilent…
Key words
assaymap, assaymapbravo, bravosulfated, sulfatedmetabolites, metabolitesdoping, dopingtof, tofsteroids, steroidsnonhydrolyzed, nonhydrolyzedmesterolone, mesterolonemetenolone, metenolonewada, wadahydrolyzed, hydrolyzedlle, lleautomated, automatedaas
Sterols - Analysis of cholesterol oxidation products (COPs) as TMS derivatives
2011|Agilent Technologies|Applications
Sterols Analysis of cholesterol oxidation products (COPs) as TMS derivatives Application Note Food Testing & Agriculture Authors Introduction Agilent Technologies, Inc. COPs are analyzed because of their potential toxicity. GC analysis was performed on their TMS derivatives to avoid thermal…
Key words
tms, tmscops, copsderivatives, derivativessterols, sterolscholesterol, cholesterolincomplete, incompletecourtesy, courtesyagriculture, agricultureoxidation, oxidationdegradation, degradationavoid, avoidprinted, printedthermal, thermalinjector, injectorusa
Screening Analysis of Steroid Profiles and Qualitative Doping Substances by GC-MS/MS
2022|Shimadzu|Applications
Application Note No. 77A Screening Analysis of Steroid Profiles and Qualitative Doping Substances by GC-MS/MS Masato Okano*1 , Mitsuhiko Sato*1, Yuma Watanabe*1, Yuki Nakagawa *2, Yuki Sakamoto *2 Life Science Life Science Abstract There are two notable trends in…
Key words
games, gamesmrpl, mrpltms, tmsblank, blankdoping, dopingmetabolite, metabolitewada, wadaaccredited, accreditedandrosterone, androsteronejuly, julysubstances, substancesnote, noteratio, ratioapplication, applicationospemifene