Aromatics and alcohols - Separation of gasoline
Applications | 2011 | Agilent TechnologiesInstrumentation
Gasoline contains various aromatic and alcohol compounds that influence engine performance, emissions and regulatory compliance. Rapid and reliable analysis of these components is essential for quality control, environmental monitoring and meeting industry standards.
This application note illustrates a gas chromatographic method using an Agilent TCEP column to separate and analyze 12 key constituents in gasoline. The primary objective is to achieve complete baseline resolution within a minimal run time, facilitating high-throughput testing in fuel laboratories.
The method achieved clear separation of 12 analytes—including n-undecane, methanol, ethanol, various butanols and aromatics such as benzene, toluene, ethylbenzene and propylbenzene—in just over ten minutes. Retention times were highly reproducible, with sharp peak shapes and minimal coelution, demonstrating the column’s ability to handle both polar and nonpolar compounds in a single run.
Emerging developments may include temperature-programmed gradients to further improve separation of complex mixtures, coupling with mass spectrometry for definitive compound identification, and miniaturized or microfluidic columns to reduce analysis time and solvent consumption. Integration of automated sample handling and advanced data analytics will streamline fuel analysis and enhance laboratory efficiency.
The Agilent TCEP capillary column method offers a fast, reliable and versatile solution for the separation of aromatics and alcohols in gasoline. Its robust performance and short analysis time make it an ideal choice for routine QC, regulatory monitoring and research applications in fuel chemistry.
GC, GC columns, Consumables
IndustriesEnergy & Chemicals
ManufacturerAgilent Technologies
Summary
Importance of the Topic
Gasoline contains various aromatic and alcohol compounds that influence engine performance, emissions and regulatory compliance. Rapid and reliable analysis of these components is essential for quality control, environmental monitoring and meeting industry standards.
Objectives and Study Overview
This application note illustrates a gas chromatographic method using an Agilent TCEP column to separate and analyze 12 key constituents in gasoline. The primary objective is to achieve complete baseline resolution within a minimal run time, facilitating high-throughput testing in fuel laboratories.
Methodology and Instrumentation
- Technique: Capillary gas chromatography
- Column: Agilent TCEP, 0.22 mm × 50 m fused silica, 0.4 µm film thickness
- Oven temperature: Isothermal at 78 °C
- Carrier gas: Helium at 210 kPa (2.1 bar), linear velocity 26 cm/s
- Injection: Split mode at 300 µL/min, injector temperature 250 °C
- Detection: Flame ionization detector (FID) at 250 °C
Main Results and Discussion
The method achieved clear separation of 12 analytes—including n-undecane, methanol, ethanol, various butanols and aromatics such as benzene, toluene, ethylbenzene and propylbenzene—in just over ten minutes. Retention times were highly reproducible, with sharp peak shapes and minimal coelution, demonstrating the column’s ability to handle both polar and nonpolar compounds in a single run.
Benefits and Practical Applications
- High throughput: Total analysis time of approximately ten minutes supports routine quality-control workflows.
- Wide applicability: Effective for a broad range of alcohols and aromatic hydrocarbons commonly found in gasoline.
- Sensitivity and robustness: FID detection provides reliable quantification at trace levels.
- Regulatory compliance: Meets analytical requirements for monitoring aromatic content and alcohol additives.
Future Trends and Applications
Emerging developments may include temperature-programmed gradients to further improve separation of complex mixtures, coupling with mass spectrometry for definitive compound identification, and miniaturized or microfluidic columns to reduce analysis time and solvent consumption. Integration of automated sample handling and advanced data analytics will streamline fuel analysis and enhance laboratory efficiency.
Conclusion
The Agilent TCEP capillary column method offers a fast, reliable and versatile solution for the separation of aromatics and alcohols in gasoline. Its robust performance and short analysis time make it an ideal choice for routine QC, regulatory monitoring and research applications in fuel chemistry.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Alcohols, C1 – C4, aromatic hydrocarbons, C5 – C7 - Analysis of gasoline
2011|Agilent Technologies|Applications
Alcohols, C1 – C4, aromatic hydrocarbons, C5 – C7 Analysis of gasoline Application Note Energy & Fuels Authors Introduction Agilent Technologies, Inc. Gas chromatography using an Agilent CP-TCEP for Alcohols in Gasoline column separates 11 C1 to C4 alcohols and…
Key words
gasoline, gasolinetcep, tcepalcohols, alcoholsfuels, fuelscourtesy, courtesygas, gasprinted, printedcolumn, columninjector, injectorusa, usaenergy, energyauthors, authorssize, sizetechnique, techniquecarrier
Alcohols and aromatics - Separation of aromatics and alcohol from gasoline
2011|Agilent Technologies|Applications
Alcohols and aromatics Separation of aromatics and alcohol from gasoline Application Note Energy & Fuels Authors Introduction Agilent Technologies, Inc. Gas chromatography using an Agilent TCEP column separates 15 aromatics and alcohol from gasoline in 28 minutes. Conditions Peak identification…
Key words
aromatics, aromaticsgasoline, gasolinealcohols, alcoholsfuels, fuelsalcohol, alcoholprinted, printedinjector, injectorusa, usaenergy, energyauthors, authorssize, sizetechnique, techniquecarrier, carrieridentification, identificationseparation
Running ASTM Method D4815 for Determining Oxygenates in Gasoline on the Agilent 6820 GC
2004|Agilent Technologies|Applications
Running ASTM Method D4815 for Determining Oxygenates in Gasoline on the Agilent 6820 GC Application Gasoline Analysis and Environmental Protection Authors Introduction ChunXiao Wang Agilent Technologies Co., Ltd. (Shanghai) 412 YingLun Road Waigaoqiao Free Trade Zone Shanghai 200131, P.R.C. Unleaded…
Key words
butanol, butanoldme, dmetcep, tcepfid, fidbackflush, backflushdipe, dipetert, tertpropanol, propanolcerity, ceritymtbe, mtberepeatability, repeatabilityvalve, valvetame, tamearea, areainlet
2-Butanol, n-C13 and 4.4 dimethyl-2-pentanone
2011|Agilent Technologies|Applications
2-Butanol, n-C13 and 4.4 dimethyl-2-pentanone Application Note Energy & Fuels Authors Introduction Agilent Technologies, Inc. Gas chromatography with an Agilent TCEP column separates 2-butanol, n-C13 and 4.4 dimethyl-2-pentanone in ten minutes. Conditions Technique : GC-capillary Column : Agilent TCEP, 0.22…
Key words
fuels, fuelsprinted, printedinjector, injectorusa, usaenergy, energyauthors, authorssize, sizetechnique, techniquesample, samplecarrier, carrieridentification, identificationsolvent, solventdetector, detectornote, notepeak