How to Choose the Proper SPME Fiber
Technical notes | 1999 | MerckInstrumentation
Solid phase microextraction (SPME) has become a cornerstone technique for rapid, solvent-free sampling of organic analytes in environmental, food, and forensic laboratories. Proper selection of the fiber coating is vital to maximize sensitivity, selectivity, and reproducibility when targeting compounds of varying volatility, polarity, and molecular weight.
This investigation evaluated six commercially available SPME fiber coatings for their extraction efficiency across a range of small volatile analytes (molecular weight 58–89) at 1 ppm and larger organic compounds (molecular weight up to 499) at 75 ppb in aqueous matrices. The study aimed to establish general recommendations for fiber choice based on analyte properties and experimental conditions.
The study proceeded in two phases:
For small volatiles (mw < 90), the 85 µm Carboxen/PDMS fiber delivered responses over 100 times greater than alternatives, due to adsorption of small molecules into Carboxen’s porous network. An exception was isopropylamine, for which a DVB/Carboxen coating provided superior affinity, although Carboxen/PDMS and PDMS/DVB were also effective. For higher molecular weight compounds, no single coating dominated: liquid-phase coatings such as Carbowax/DVB and polyacrylate (PA) excelled with polar analytes, while DVB/Carboxen offered a broad range performance by combining retention in both layers. Notably, PA unexpectedly extracted nonpolar aromatics, likely via π–π interactions, and Carboxen retained some high-mass analytes too strongly (e.g., PAHs), limiting desorption. Decachlorobiphenyl extraction by Carboxen/PDMS suggested steric hindrance mitigates overly strong binding.
Adoption of these selection guidelines can:
Advances in mixed-phase and nanostructured fiber coatings are expected to further tailor selectivity and sensitivity. Integration with automated sampling platforms and coupling to high-resolution mass spectrometry will expand SPME’s utility in metabolomics and real-time field monitoring. Ongoing patent developments in fiber materials promise enhanced robustness and lower analytical cost.
This systematic evaluation demonstrates that fiber selection should be guided by analyte volatility, polarity, and molecular size. The versatile Carboxen/PDMS fiber is recommended for small volatiles, while mixed and polar coatings offer broader applicability for larger or functionalized compounds. Final fiber choice should be confirmed by target-specific testing under real sample conditions.
SPME, Consumables
IndustriesManufacturerMerck
Summary
Significance of Topic
Solid phase microextraction (SPME) has become a cornerstone technique for rapid, solvent-free sampling of organic analytes in environmental, food, and forensic laboratories. Proper selection of the fiber coating is vital to maximize sensitivity, selectivity, and reproducibility when targeting compounds of varying volatility, polarity, and molecular weight.
Objectives and Overview of the Study
This investigation evaluated six commercially available SPME fiber coatings for their extraction efficiency across a range of small volatile analytes (molecular weight 58–89) at 1 ppm and larger organic compounds (molecular weight up to 499) at 75 ppb in aqueous matrices. The study aimed to establish general recommendations for fiber choice based on analyte properties and experimental conditions.
Used Instrumentation
- Gas chromatograph coupled with mass spectrometer (GC/MS) for analyte detection and quantitation
- SPME fiber holders compatible with manual and automated sampling
- 40 mL headspace vials and five-position aluminum vial holder for controlled heating and stirring during extraction
Methodology
The study proceeded in two phases:
- Volatile analytes (mw 58–89) were spiked into water at 1 ppm and extracted using six fiber coatings. Absolute GC/MS responses were compared to identify top-performing fibers.
- Larger analytes (mw up to 499) were introduced at 75 ppb across three pH levels. Extractions employed eight different fibers and uncoated controls, with GC/MS evaluation of absolute responses under each condition.
Main Results and Discussion
For small volatiles (mw < 90), the 85 µm Carboxen/PDMS fiber delivered responses over 100 times greater than alternatives, due to adsorption of small molecules into Carboxen’s porous network. An exception was isopropylamine, for which a DVB/Carboxen coating provided superior affinity, although Carboxen/PDMS and PDMS/DVB were also effective. For higher molecular weight compounds, no single coating dominated: liquid-phase coatings such as Carbowax/DVB and polyacrylate (PA) excelled with polar analytes, while DVB/Carboxen offered a broad range performance by combining retention in both layers. Notably, PA unexpectedly extracted nonpolar aromatics, likely via π–π interactions, and Carboxen retained some high-mass analytes too strongly (e.g., PAHs), limiting desorption. Decachlorobiphenyl extraction by Carboxen/PDMS suggested steric hindrance mitigates overly strong binding.
Benefits and Practical Applications
Adoption of these selection guidelines can:
- Enhance detection limits for trace volatiles and semivolatiles in water and biological matrices
- Reduce method development time by narrowing fiber choices based on analyte class
- Support diverse applications in environmental monitoring, food flavor analysis, and forensic screening
Future Trends and Possibilities
Advances in mixed-phase and nanostructured fiber coatings are expected to further tailor selectivity and sensitivity. Integration with automated sampling platforms and coupling to high-resolution mass spectrometry will expand SPME’s utility in metabolomics and real-time field monitoring. Ongoing patent developments in fiber materials promise enhanced robustness and lower analytical cost.
Conclusion
This systematic evaluation demonstrates that fiber selection should be guided by analyte volatility, polarity, and molecular size. The versatile Carboxen/PDMS fiber is recommended for small volatiles, while mixed and polar coatings offer broader applicability for larger or functionalized compounds. Final fiber choice should be confirmed by target-specific testing under real sample conditions.
Reference
- Shirey R. Selecting the Appropriate SPME Fiber for Your Application Needs (1999 EAS paper, T499232).
- US Patent 5,691,206; European Patent 0523092 covering DVB/Carboxen/PDMS technology.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
SPME-Adsorption versus Absorption: Which Fiber is Best for Your Application?
1999|Merck|Presentations
SUPELCO SPME-Adsorption versus Absorption: Which Fiber is Best for Your Application? Robert E. Shirey and Raymond F. Mindrup ©1999 Sigma-Aldrich Co. 00-0001 T400011 The continuing development of SPME fiber coatings has presented some difficulties for analyst to select the appropriate…
Key words
dvb, dvbfiber, fibersupelco, supelcofibers, fiberspdms, pdmscarboxen, carboxenanalytes, analytesadsorbent, adsorbentpacrylate, pacrylateabsorbent, absorbentnitropropane, nitropropanebare, barepolar, polaranalyte, analyteslide
Optimization of Extraction Conditions and Fiber Selection for Low-Molecular Weight Analytes and Semi-volatile Analytes Using SPME
|Merck|Presentations
SUPELCO Optimization of Extraction Conditions and Fiber Selection for Low-Molecular Weight Analytes and Semi-volatile Analytes Using SPME Robert E. Shirey and Leonard M. Sidisky Supelco Inc., Bellefonte, PA USA ©1999 Sigma-Aldrich Co. SUPELCO INTRODUCTION Developing an application using SPME can…
Key words
dvb, dvbpdms, pdmssupelco, supelcopacrylate, pacrylatecarboxen, carboxenitr, itrfiber, fiberanalytes, analytescar, carbare, barefibers, fibersmethylacetate, methylacetateisopropylamine, isopropylaminepolar, polaradsorbent
SPME Resolves Difficult Matrix Problems
2000|Merck|Others
VOL 18.4 SPRING EDITION 2000 TheReporter SOLID PHASE MICROEXTRACTION Sample Prep Made Easy www.sigma-aldrich.com/TheReporter SPME Resolves Difficult Matrix Problems Fig. 1 – Complex Orange Juice Sample Extraction with SPME Sample: 25ml orange juice Fiber: 75µm Carboxen-PDMS Extraction : headspace, 30…
Key words
spme, spmecarboxen, carboxenfiber, fiberpdms, pdmsstableflex, stableflexextech, extechheadspace, headspaceconference, conferencedvb, dvbfibers, fibersvolatile, volatilemethyl, methylalcoholb, alcoholbsampling, samplingshirey
A Systematic Approach for Selecting the Appropriate SPME Fiber
1999|Merck|Presentations
SUPELCO A Systematic Approach for Selecting the Appropriate SPME Fiber Robert E. Shirey and Raymond F. Mindrup Supelco, Supelco Park, Bellefonte, PA 16823 T400156 DKF ©1999 Sigma-Aldrich Co. 00-0001 Overview of Presentation • Factors that affect fiber selection • Description…
Key words
supelco, supelcodvb, dvbfibers, fiberspacrylate, pacrylatepdms, pdmsnitropropane, nitropropanecarboxen, carboxenpropionitrile, propionitrilefiber, fibercar, carabsorbent, absorbentbare, bareadsorbent, adsorbentanalytes, analyteslog