A Technical Comparison of SIFT-MS and PTR-MS
Technical notes | | Syft TechnologiesInstrumentation
Real-time measurement of volatile organic compounds (VOCs) is critical in environmental monitoring, breath analysis, industrial process control and occupational safety. Soft chemical ionization techniques such as SIFT-MS and PTR-MS enable rapid, direct analysis of air samples at low parts-per-trillion levels without chromatographic separation, improving throughput and specificity.
This comparison evaluates fundamental and operational differences between Selected Ion Flow Tube Mass Spectrometry (SIFT-MS) and Proton Transfer Reaction Mass Spectrometry (PTR-MS), including the newer switchable-reagent-ion PTR variant (SRI-PTR-MS). Key aims are to assess reagent-ion generation, ion energies, fragmentation patterns, detection limits, quantitation approaches and user workflows.
Both techniques employ a flow tube reactor and mass spectrometric detection. SIFT-MS (Syft Voice200) generates H3O+, NO+ and O2+ ions via microwave discharge and quadrupole selection, thermalizes them in a carrier gas, then reacts them with sample VOCs in milliseconds. PTR-MS uses a hollow-cathode discharge to form H3O+ (and optionally NO+ or O2+ in SRI-PTR-MS) but lacks instantaneous ion selection, relying on drift-tube electric fields. Detection is by quadrupole or time-of-flight analyzers.
Future developments may include miniaturized SIFT-MS systems for portable field analysis, enhanced TOF mass analyzers for greater resolution, integration with artificial-intelligence-driven data analysis, expanded reagent-ion chemistries for targeted compound classes, and cloud-based networks for centralized monitoring and remote diagnostics.
SIFT-MS demonstrates clear technical and operational advantages over PTR-MS, notably in reagent-ion control, soft ionization, sensitivity at higher masses, absolute quantitation and user accessibility. These benefits translate into faster, more reliable VOC profiling across diverse applications.
SIFT-MS
IndustriesManufacturerSyft Technologies
Summary
Význam tématu
Real-time measurement of volatile organic compounds (VOCs) is critical in environmental monitoring, breath analysis, industrial process control and occupational safety. Soft chemical ionization techniques such as SIFT-MS and PTR-MS enable rapid, direct analysis of air samples at low parts-per-trillion levels without chromatographic separation, improving throughput and specificity.
Cíle a přehled studie
This comparison evaluates fundamental and operational differences between Selected Ion Flow Tube Mass Spectrometry (SIFT-MS) and Proton Transfer Reaction Mass Spectrometry (PTR-MS), including the newer switchable-reagent-ion PTR variant (SRI-PTR-MS). Key aims are to assess reagent-ion generation, ion energies, fragmentation patterns, detection limits, quantitation approaches and user workflows.
Použitá metodika a instrumentace
Both techniques employ a flow tube reactor and mass spectrometric detection. SIFT-MS (Syft Voice200) generates H3O+, NO+ and O2+ ions via microwave discharge and quadrupole selection, thermalizes them in a carrier gas, then reacts them with sample VOCs in milliseconds. PTR-MS uses a hollow-cathode discharge to form H3O+ (and optionally NO+ or O2+ in SRI-PTR-MS) but lacks instantaneous ion selection, relying on drift-tube electric fields. Detection is by quadrupole or time-of-flight analyzers.
Hlavní výsledky a diskuse
- Reagent-ion switching: SIFT-MS achieves <10 ms switching among three ions, enabling multi-ion, single-scan discrimination of isomers; SRI-PTR-MS requires seconds and off-line gas changes.
- Ion energy distributions: Thermalized SIFT-MS ions yield predictable, ultra-soft ionization with minimal fragmentation; PTR-MS ions exhibit higher, variable energies, causing spectral confusion and poorer quantitation.
- Fragmentation and specificity: SIFT-MS produces fewer product ions, reducing interferences and eliminating the need for GC separation. PTR-MS shows extensive fragmentation for compounds such as acetaldehyde and ketones.
- Sensitivity and resolution: Advanced ion optics in SIFT-MS boost sensitivity at m/z >100. PTR-MS quadrupoles struggle above m/z 120; TOF variants improve resolution but at higher cost and reduced sensitivity.
- Quantitation: SIFT-MS uses generic kinetic databases for absolute quantitation without calibration standards. PTR-MS requires drift-tube-specific rate coefficients or frequent calibrations.
- Operational factors: SIFT-MS software supports touchscreen workflows for non-technical users, remote network integration, automated validation and online support. PTR-MS systems demand expert operation, lack remote access and have minimal automation.
Přínosy a praktické využití metody
- Instantaneous quantification of breath biomarkers (menthol, acetone) for medical and sports applications.
- Continuous monitoring of industrial emissions and environmental pollutants.
- Workplace safety screening for toxic gas exposure.
- Quality control in food, fragrance and flavor industries.
Budoucí trendy a možnosti využití
Future developments may include miniaturized SIFT-MS systems for portable field analysis, enhanced TOF mass analyzers for greater resolution, integration with artificial-intelligence-driven data analysis, expanded reagent-ion chemistries for targeted compound classes, and cloud-based networks for centralized monitoring and remote diagnostics.
Závěr
SIFT-MS demonstrates clear technical and operational advantages over PTR-MS, notably in reagent-ion control, soft ionization, sensitivity at higher masses, absolute quantitation and user accessibility. These benefits translate into faster, more reliable VOC profiling across diverse applications.
Reference
- Prince, M. J., Milligan, D. E., McEwan, M. J. Rapid Commun. Mass Spectrom. 2010, 24, 1763–1769.
- Spanel, P., Smith, D. Int. J. Mass Spectrom. Ion Processes 1997, 165/166, 25–37.
- Blake, R. S., Monks, P. S., Ellis, A. M. Int. J. Mass Spectrom. Ion Processes 2006, 254, 85–93.
- Spanel, P., Smith, D. Int. J. Mass Spectrom. Ion Processes 1998, 172, 137–147.
- NIST Chemistry WebBook.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
SIFT-MS - SELECTED ION FLOW TUBE MASS SPECTROMETRY
2017|Syft Technologies|Brochures and specifications
SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW \ SYFT TECHNOLOGIES CONTENTS 1. An overview of SIFT-MS 2. Principles of SIFT-MS SELECTED ION FLOW TUBE MASS SPECTROMETRY TECHNOLOGY OVERVIEW a. Why chemical ionization? b. Why multiple reagent ions? c.…
Key words
sift, siftsyft, syftreagent, reagention, ionions, ionsselected, selectedtube, tubeionization, ionizationabsolute, absolutemass, massinstruments, instrumentsproduct, productreal, realoverview, overviewtechnologies
Interfacing a Markes Unity2TM Thermal Desorber with the Syft Voice200® SIFT-MS
|Markes|Technical notes
REPORT | Thermal Desorption – SIFT-MS Interfacing a Markes Unity2TM Thermal Desorber with the Syft Voice200® SIFT-MS Thermal desorption has become a commonly used technique for transferring volatile and semi-volatile organic compounds into a gas chromatograph, or gas chromatography –…
Key words
sift, siftvtotal, vtotaldesorption, desorptionsorbent, sorbentsyft, syftmanalyte, manalytethermal, thermaldesorbed, desorbedfocusing, focusinganalyte, analytemedia, mediagas, gasunits, unitscompounds, compoundsmass
Detection and Quantitation of Carbonyl Sulfide, Using SIFT-MS
|Syft Technologies|Others
REPORT | Carbonyl Sulfide Detection, Using SIFT-MS Detection and Quantitation of Carbonyl Sulfide, Using SIFT-MS Carbonyl sulfide (COS; also known as carbon sulfoxide) was proposed as a fumigant1 by the Stored Grain Research Laboratory of the Commonwealth Scientific and Industrial…
Key words
sift, siftsulfide, sulfidecarbonyl, carbonylenquiries, enquiriesdetection, detectionknown, knownfsm, fsmcsiro, csirocommonwealth, commonwealthions, ionsfumigants, fumigantsconcentration, concentrationindustrial, industrialppb, ppbquantify
Real-Time Ambient Air Monitoring Campaigns Using Syft SIFT-MS
2014|Syft Technologies|Applications
Syft Technologies | Application Note | Environmental Analysis Real-Time Ambient Air Monitoring Campaigns Using Syft SIFT-MS Key Benefits Analytical results in seconds Detection limits in the pptv range Direct air analysis without preconcentration or drying Readily deployed to site and…
Key words
syft, syftsift, siftdeployed, deployedpptv, pptvvocs, vocsreal, realair, airppbv, ppbvbrochure, brochuremonitoring, monitoringanalysis, analysispreconcentration, preconcentrationtechnologies, technologiesgusty, gustyper