REAL-TIME SPECIATION OF ETHYLBENZENE FROM THE XYLENES USING SIFT-MS
Applications | | AnatuneInstrumentation
Real-time differentiation of ethylbenzene from xylene isomers is increasingly important for regulatory compliance, occupational exposure monitoring, and environmental air quality assessment. Traditional direct mass spectrometry cannot distinguish these C8H10 isomers without chromatographic separation, leading to the need for rapid, on-line speciation methods that support time-resolved measurements in complex matrices.
This application note presents a novel selected ion flow tube mass spectrometry (SIFT-MS) approach that exploits differing product ion chemistry of O2+ reagent ions to achieve direct, real-time speciation of ethylbenzene and total xylenes. Calibration strategies and demonstration experiments in a laboratory air matrix validate the method’s performance.
Expansion of reagent ion switching and automated calibration routines may extend SIFT-MS speciation to additional aromatic and aliphatic isomeric VOCs. Integration with field-deployable and IoT-enabled platforms will facilitate distributed, real-time air quality networks and on-line industrial process monitoring.
The O2+ reagent ion in SIFT-MS, combined with straightforward calibration of product ion ratios, delivers accurate, real-time separation of ethylbenzene and xylenes without chromatography. This approach enhances sensitivity, temporal resolution, and operational simplicity for diverse analytical applications.
SIFT-MS
IndustriesEnergy & Chemicals
ManufacturerSyft Technologies
Summary
Importance of the Topic
Real-time differentiation of ethylbenzene from xylene isomers is increasingly important for regulatory compliance, occupational exposure monitoring, and environmental air quality assessment. Traditional direct mass spectrometry cannot distinguish these C8H10 isomers without chromatographic separation, leading to the need for rapid, on-line speciation methods that support time-resolved measurements in complex matrices.
Objectives and Study Overview
This application note presents a novel selected ion flow tube mass spectrometry (SIFT-MS) approach that exploits differing product ion chemistry of O2+ reagent ions to achieve direct, real-time speciation of ethylbenzene and total xylenes. Calibration strategies and demonstration experiments in a laboratory air matrix validate the method’s performance.
Methodology and Instrumentation
- Instrument: Syft Technologies Voice200ultra SIFT-MS with rapid switching between H3O+, NO+, and O2+ reagent ions.
- Sampling: Ambient air drawn at approximately 25 standard cubic centimetres per minute (sccm) through a high-performance inlet.
- Reagent Ion Chemistry: H3O+ and NO+ provide combined C8H10 signals, while O2+ yields two major product ions (m/z 91 and 106) with isomer-specific branching ratios.
- Calibration: Defined mixtures of ethylbenzene and xylenes (20/80, 50/50, 80/20) at 150 ppbv and 10 ppmv establish linear correlations between the 91/106 product ion ratio and isomeric composition.
Main Results and Discussion
- NO+ reagent ion monitoring tracked total C8H10 concentrations continuously over 140 minutes in a complex lab air environment, detecting single-millilitre headspace injections.
- O2+ product ion ratios (m/z 91 vs. 106) differed substantially between ethylbenzene (70:30) and xylenes (20:80), enabling clear speciation based on calibrated ratio functions.
- Calibration curves exhibited excellent linearity and y-intercepts matching theoretical branching ratios, confirming method accuracy across low ppbv to ppmv ranges.
- Demonstrations achieved temporal resolution of ~3 seconds, distinguishing sequential exposures to m-xylene, ethylbenzene, and a 50/50 mixture in real time.
Benefits and Practical Applications
- Avoids time-consuming chromatographic separation, enabling high-throughput and continuous monitoring.
- Supports workplace air quality surveillance, vehicle interior VOC analysis, process control, and environmental compliance testing.
- Offers rapid feedback to laboratories, contract research organizations, and in-process monitoring applications.
Future Trends and Potential Applications
Expansion of reagent ion switching and automated calibration routines may extend SIFT-MS speciation to additional aromatic and aliphatic isomeric VOCs. Integration with field-deployable and IoT-enabled platforms will facilitate distributed, real-time air quality networks and on-line industrial process monitoring.
Conclusion
The O2+ reagent ion in SIFT-MS, combined with straightforward calibration of product ion ratios, delivers accurate, real-time separation of ethylbenzene and xylenes without chromatography. This approach enhances sensitivity, temporal resolution, and operational simplicity for diverse analytical applications.
Reference
- NIOSH International Chemical Safety Cards. CDC IPCS NENG Series; accessed December 5, 2017.
- Prince BJ, Milligan DB, McEwan MJ (2010). Application of SIFT-MS to real-time atmospheric monitoring. Rapid Commun. Mass Spectrom. 24, 1763; Langford VS, Graves I, McEwan MJ (2014). Rapid monitoring of volatile organic compounds: a comparison between gas chromatography/mass spectrometry and SIFT-MS. Rapid Commun. Mass Spectrom. 28, 10.
- Spanel P, Smith D (1998). SIFT studies of the reactions of H3O+, NO+, and O2+ with aromatic and aliphatic hydrocarbons. Int. J. Mass Spectrom. 181, 1.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
High-Throughput Analysis of Volatile Compounds in Air, Water and Soil Using SIFT-MS
|GERSTEL|Scientific articles
High-Throughput Analysis of Volatile Compounds in Air, Water and Soil Using SIFT-MS Mark J. Perkins,1 Vaughan S. Langford,2 Murray J. McEwan2,3 1 Anatune Ltd, Girton Road, Cambridge, CB3 0NA, United Kingdom \ 2Syft Technologies Ltd, 3 Craft Place, Christchurch 8024,…
Key words
sift, siftethylbenzene, ethylbenzenebtex, btexmethanolic, methanolicxylene, xylenexylenes, xylenestoluene, toluenesoil, soilisomers, isomersppbv, ppbvheadspace, headspaceetb, etbcompounds, compoundsconcentrations, concentrationslymphocytes
RAPID ANALYSIS OF BTEX IN WATER USING AUTOMATED SIFT-MS
|GERSTEL|Applications
AS209 Wellbrook Court | Girton Road | Cambridge | CB3 0NA | tel: +44 (0) 1223 279210 | fax: +44 (0) 1223 279253 [email protected] | anatune.co.uk RAPID ANALYSIS OF BTEX IN WATER USING AUTOMATED SIFT-MS Selected ion flow tube mass…
Key words
sift, siftbtex, btexheadspace, headspaceethylbenzene, ethylbenzenesiftms, siftmsppbv, ppbvrapid, rapidmass, massreagent, reagentgerstel, gerstelshsift, shsiftrefrences, refrenceseffectively, effectivelyselected, selectedions
SPECIATION OF DICHLOROMETHANE AND CHLOROFORM USING NEGATIVE ION SIFT-MS
|GERSTEL|Applications
AS233 Wellbrook Court | Girton Road | Cambridge | CB3 0NA | | tel: +44 (0) 1223 279210 | fax: +44 (0) 1223 279253 | email: [email protected] | anatune.co.uk SPECIATION OF DICHLOROMETHANE AND CHLOROFORM USING NEGATIVE ION SIFT-MS Mark Perkins,…
Key words
chlorofor, chloroforsift, siftchloroform, chloroformppmv, ppmvheadspace, headspacedichloromethane, dichloromethanebranching, branchinglinearity, linearityconcentratio, concentratiorounding, roundingsuites, suitesrepeatability, repeatabilityreaction, reactionion, ionconstants
Analysis of Vehicle Interior Air Quality (VIAQ) using SIFT-MS
2017|Syft Technologies|Applications
Anatune Ltd Unit 4, Wellbrook Court, Girton Road, Cambridge, CB3 0NA, UK Tel: +44 (0) 1223279210 Fax: +44 (0) 1223279253 Email: [email protected] Internet: www.anatune.co.uk Copyright © 2017 Anatune Ltd. All Rights Reserved. Anatune is a trademark of Anatune Ltd. Analysis…
Key words
sift, siftacetaldehyde, acetaldehydeacrolein, acroleinlimit, limitviaq, viaqinterior, interiorformaldehyde, formaldehydeacetone, acetoneset, setbutanal, butanalpropanal, propanalpentanal, pentanalethylbenzene, ethylbenzenestyrene, styrenetube