Improved High Temperature Simulated Distillation (ASTM D6352 and D7169) Using Zebron™ ZB-1XT SimDist Metal GC Columns

Applications | 2010 | PhenomenexInstrumentation
GC, GC columns, Consumables
Industries
Energy & Chemicals
Manufacturer
Phenomenex

Summary

Importance of the Topic


The precise characterization of heavy hydrocarbon fractions is essential for modern refinery operations, quality control, and process optimization. Traditional high-temperature simulated distillation methods (ASTM D6352 and D7169) are generally limited to C90–C100 range, constraining the ability to profile heavier boiling components in crude and fuel streams. Extending analytical range and enhancing column stability directly supports improved process planning, reduced downtime, and increased product yields.

Objectives and Overview of the Study


This work evaluates the performance of the Zebron ZB-1XT SimDist metal GC column featuring Glass Infusion™ Technology for high-temperature simulated distillation. The primary goals were to:
  • Extend the boiling range analysis from C100 to C120 while complying with ASTM D6352/D7169 suitability criteria.
  • Assess column-to-column reproducibility and chromatographic efficiency.
  • Compare thermal stability and lifetime against competitive columns.

Used Instrumentation and Methodology


The study employed a GC system equipped with a flame ionization detector (FID). Key parameters included:
  • Column: Zebron ZB-1XT SimDist, 5 m × 0.53 mm i.d. × 0.09 µm film thickness.
  • Carrier gas: Hydrogen at 1.93 mL/min or helium at 30–34 mL/min constant flow.
  • Injection: 1.0 µL split 100:1 or on-column at 38–53 °C.
  • Temperature program: Initial hold at 35–53 °C, ramp to 430–450 °C at 9–10 °C/min, final hold for 10–20 min; FID at 325–450 °C.
  • Active test mix: Polar and nonpolar probes (e.g., 4-chlorophenol, dicyclohexylamine) to evaluate surface interactions.
  • Lifetime test: Repeated Polywax® 1000 injections at 400 °C over 90 h, monitoring C50/C52 resolution.

Main Results and Discussion


Glass Infusion™ Technology produced a smooth, uniform glass coating on the internal metal surface, eliminating exposed metal sites and ensuring consistent stationary phase bonding. Comparative data showed:
  • Sharp, symmetrical peaks for acidic and basic probes on Zebron ZB-1XT versus tailing and adsorption on non-infused columns.
  • Sustained resolution above 2.3 for C50/C52 over 90 h at 400 °C, well above the ASTM D6352 minimum of 2.0. Competing columns dropped near failure zones after 70–80 h.
  • Successful elution of hydrocarbons up to C120 within the temperature program, meeting D7169 criteria (resolution ≥ 1.8, skew factors within 0.8–1.2 range).
  • Chromatographic profiling of Yeates crude oil demonstrated elution of species beyond C120 at 450 °C, reducing residue buildup and carryover risks.

Benefits and Practical Applications of the Method


The Zebron ZB-1XT SimDist column offers:
  • Extended boiling-point range analysis for comprehensive crude and fuel characterization.
  • Superior column-to-column reproducibility from individual QC testing.
  • Enhanced thermal stability and longer operational lifetime, lowering maintenance and replacement costs.
  • Improved process data for refinery cracking optimization, yield improvement, and QA/QC.

Future Trends and Potential Applications


Potential developments include:
  • Pushing simulated distillation beyond C120 with further material innovations.
  • Integration with advanced detectors (MS, IR) for structural assignment of heavy ends.
  • Real-time refinery process monitoring with on-line GC systems.
  • Utilization of machine learning models to predict feedstock performance and optimize separation conditions.

Conclusion


The Zebron ZB-1XT SimDist metal GC column, leveraging Glass Infusion Technology, significantly enhances high-temperature simulated distillation by extending analysis to C120, assuring robust column performance, and increasing operational efficiency. This solution addresses critical needs in refinery analytics and quality control, delivering reliable data, longer column life, and reduced total cost of ownership.

Reference


  • Kelly K, Countryman S, Fernandez C, Nguyen N. Improved High Temperature Simulated Distillation (ASTM D6352 and D7169) Using Zebron™ ZB-1XT SimDist Metal GC Columns. Phenomenex Application Note TN-2043, 2010.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Simulated Distillation Metal GC Columns
Simulated Distillation Metal GC Columns
2011|Phenomenex|Brochures and specifications
Simulated Distillation Metal GC Columns Zebron ZB-1XT SimDist with Glass Infusion Technology ™ ™ Consistent and Reliable Results, Guaranteed. 5 Reasons to Switch to Zebron ZB-1XT SimDist GC Columns ™ 1. New Glass Infusion™ Technology p. 3 2. Consistency and…
Key words
zebron, zebronphenomenex, phenomenexlock, locknut, nutsimdist, simdistcool, coolferrules, ferrulesrestek, restekprice, pricevarian, varianinfusion, infusionmin, minglass, glassefficiency, efficiencytested
Sharper Peak Shape and Better Efficiency through Uniform Glass Infusion™ Coating Technology
Easily find ASTM and Fuel applications at: www.phenomenex.com/ZB1XT Sharper Peak Shape and Better Efficiency through Uniform Glass Infusion™ Coating Technology GC Columns Performance Benefits ™ 1. Sharper Peaks and Higher Efficiency: Glass Infusion Technology Provides Uniform Coating and Minimizes Unwanted…
Key words
glass, glassinfusion, infusionsimdist, simdistguarantee, guaranteeuniform, uniforminfused, infusedmetal, metalexposed, exposedshape, shapedistillates, distillatesadsorption, adsorptiontailing, tailingbetter, betterzebron, zebronefficiency
Zebron ZB-DHA-PONA GC Column
Zebron ZB-DHA-PONA GC Column
2019|Phenomenex|Brochures and specifications
™ Introducing ZB-DHA-PONA • Designed and Tested for Detailed Hydrocarbon Analysis • Excellent Response and Peak Symmetry for Polar Oxygenates • Suitable for DHA, PONA, PIONA, PIANO, and ASTM Methods (D5134, D5441, D5501, D6729, D6730, D6733) www.phenomenex.com/dhapona G C C…
Key words
pona, ponadha, dhazebron, zebronphenomenex, phenomenexcolu, colugas, gasfilter, filterclick, clickusa, usaindicator, indicatormanagement, managementprice, pricemtbe, mtbetrap, traphydrocarbon
GC Method Development Special - Optimize GC Column Selection and Save!
GC Method Development Special Optimize GC Column Selection and Save! Column selection tips and guidelines inside Introducing Phase Selection the Zebron Tips Experience ™ Selectivity Has the Biggest Impact on Resolution Resolution between two analytes is mainly determined by the…
Key words
price, pricelimits, limitsphenomenex, phenomenexxlb, xlbproprietary, proprietaryzebron, zebronexclusive, exclusivephase, phasewax, waxsemivolatiles, semivolatilesinferno, infernobioethanol, bioethanolwaxplus, waxplusstabilwax, stabilwaxffap
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike