Accurate pesticide measurement ensures compliance with environmental and food safety regulations and supports quality control in various industries.
High-resolution separation and sensitive detection of trace-level residues are critical for reliable monitoring and risk assessment.
This work evaluates the performance of Zebron GC columns for advanced pesticide testing. It compares specialized stationary phases designed for chlorinated pesticides, multi-residue screens, and semi-volatile compounds under multiple EPA methods. The study aims to demonstrate enhanced selectivity, inertness, and flexibility without frequent column changes.
ZB-CLPesticides phases achieved baseline separation of 22 chlorinated analytes within 10 minutes, matching or exceeding performance of competitive phases. MultiResidue columns resolved over 112 compounds, with improved inertness preventing thermal degradation of sensitive analytes like DDT and endrin. ZB-SemiVolatiles demonstrated stable inert performance, sharpening peaks for acids, amines, and semi-volatiles down to 0.2 ng on-column. Temperature limits to 320–340 °C provided robust operation across methods.
Continued development of stationary phases with tailored polarity and pore structures will address emerging contaminants and isomeric separations. Integration with GC–MS/MS and high-throughput automation will further enhance sensitivity and selectivity. Green chromatography approaches using alternative carrier gases and reduced solvent consumption are expected to grow. Advancements in data analytics and machine learning may optimize method development and predictive maintenance.
Zebron GC columns deliver versatile and reliable solutions for pesticide analysis across a wide range of methods. Their tailored selectivity, robust inertness, and broad temperature tolerance enable high-resolution separations and low-level detection, meeting the demands of modern regulatory and research environments.
GC columns, Consumables
IndustriesManufacturerPhenomenex
Summary
Importance of the Topic
Accurate pesticide measurement ensures compliance with environmental and food safety regulations and supports quality control in various industries.
High-resolution separation and sensitive detection of trace-level residues are critical for reliable monitoring and risk assessment.
Study Overview and Objectives
This work evaluates the performance of Zebron GC columns for advanced pesticide testing. It compares specialized stationary phases designed for chlorinated pesticides, multi-residue screens, and semi-volatile compounds under multiple EPA methods. The study aims to demonstrate enhanced selectivity, inertness, and flexibility without frequent column changes.
Methodology and Instrumentation
- Columns: Zebron ZB-CLPesticides-1 and -2 (30 m×0.32 mm, df 0.32/0.25 µm), ZB-MultiResidue-1 and -2 (30 m×0.25 mm, df 0.25/0.20 µm), ZB-SemiVolatiles (30 m×0.25 mm, df 0.25 µm).
- Injection: Splitless or pulsed splitless at 250–260 °C, 1 µL.
- Carrier Gas: Hydrogen (3.5 mL/min) for CLPesticides, Helium (0.9–1.2 mL/min) for multi-residue and semi-volatiles.
- Detectors: Electron Capture (ECD) at 330 °C for chlorinated pesticides; Mass Spectrometry (MSD) at 320 °C for multi-residue; MS for semi-volatiles.
- Oven Programs: Rapid temperature ramps for efficient separation from 80–85 °C to 300–330 °C tailored per application.
- Sample Preparation: Standard mixes of chlorinated pesticides at 100 ng/mL in hexane; multi-residue at 1 ppm in dichloromethane; drinking water volatiles spiked for semi-volatiles.
Main Results and Discussion
ZB-CLPesticides phases achieved baseline separation of 22 chlorinated analytes within 10 minutes, matching or exceeding performance of competitive phases. MultiResidue columns resolved over 112 compounds, with improved inertness preventing thermal degradation of sensitive analytes like DDT and endrin. ZB-SemiVolatiles demonstrated stable inert performance, sharpening peaks for acids, amines, and semi-volatiles down to 0.2 ng on-column. Temperature limits to 320–340 °C provided robust operation across methods.
Practical Benefits and Applications
- Single-column capability for multiple EPA methods (8081, 8082, 8151, 504, 505, 508, 552) reduces downtime and simplifies workflows.
- Enhanced selectivity supports complex sample matrices in environmental, food, and QA/QC laboratories.
- Improved inertness extends column lifetime and maintains sensitivity for labile compounds.
- Guaranteed performance alternative with refund policy fosters user confidence.
- Compatibility with GC/MS and GC/ECD detection enables flexible analytical setups.
Future Trends and Applications
Continued development of stationary phases with tailored polarity and pore structures will address emerging contaminants and isomeric separations. Integration with GC–MS/MS and high-throughput automation will further enhance sensitivity and selectivity. Green chromatography approaches using alternative carrier gases and reduced solvent consumption are expected to grow. Advancements in data analytics and machine learning may optimize method development and predictive maintenance.
Conclusion
Zebron GC columns deliver versatile and reliable solutions for pesticide analysis across a wide range of methods. Their tailored selectivity, robust inertness, and broad temperature tolerance enable high-resolution separations and low-level detection, meeting the demands of modern regulatory and research environments.
References
- U.S. EPA. Method 8081: Organochlorine Pesticides by Gas Chromatography.
- U.S. EPA. Method 8082: Organochlorine Pesticides, Extended.
- U.S. EPA. Method 8151: Herbicides by Gas Chromatography.
- U.S. EPA. Methods 504, 505, 508, 552 for haloacetic acids and related compounds.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Fast, Accurate Environmental Testing - Using Zebron GC Columns
2017|Phenomenex|Brochures and specifications
GC C o lu mn s Fast, Accurate Environmental Testing Using Zebron GC Columns Featuring • Pesticides • Diesel Range Organics • Semivolatiles • Dioxane • And more….. www.phenomenex.com/environmental Semi-Volatile Organic Compounds 137 Analytes in 16 mins Column: Zebron™ ZB-SemiVolatiles…
Key words
ecd, ecdvolatile, volatilepesticides, pesticidesnpd, npdzebron, zebronorganics, organicshrgc, hrgcchlorinated, chlorinatedpolychlorinated, polychlorinatedphenomenex, phenomenexlength, lengthpurgeable, purgeableorganic, organicpurge, purgetrap
Persistent Organic Pollutants (POPs) - GC Application Guide
2022|Phenomenex|Guides
™ GC Application Guide Persistent Organic Pollutants (POPs) www.phenomenex.com/Zebron GC C ol umns INTRODUCTION Persistent organic pollutants (POPs) are organic chemical substances produced either intentionally or as byproducts of industrial activities. Sources of pollution from POPs include the improper use…
Key words
zebron, zebronsemivolatiles, semivolatilesphenomenex, phenomenexpah, pahecd, ecddioxin, dioxinbenzo, benzoorganic, organicfluoranthene, fluoranthenevolatile, volatilepesticides, pesticidesdioxins, dioxinscompounds, compoundspolychlorinated, polychlorinatedmin
GC Product Guide 2025/26
2025|Phenomenex|Brochures and specifications
GC Product Guide 2025/26 Welcome Table of Contents 2 07 Improved Performance Columns 34 High Temperature Columns 44 Standard Columns 52 GC ACCESSORIES 66 Inlet Base Seals 67 Installation Nuts 69 Ferrules 71 O-rings 73 Septa/Septum 73 Inlet Liners 75…
Key words
appendices, appendiceszebron, zebronaccessories, accessoriescolumns, columnscont’d, cont’dcontents, contentsphenomenex, phenomenextable, tablecolumn, columnordering, orderingpolarity, polarityguard, guardphase, phasesemivolatiles, semivolatilessyringes
GC Method Development Special - Optimize GC Column Selection and Save!
2012|Phenomenex|Guides
GC Method Development Special Optimize GC Column Selection and Save! Column selection tips and guidelines inside Introducing Phase Selection the Zebron Tips Experience ™ Selectivity Has the Biggest Impact on Resolution Resolution between two analytes is mainly determined by the…
Key words
price, pricelimits, limitsphenomenex, phenomenexxlb, xlbproprietary, proprietaryzebron, zebronexclusive, exclusivephase, phasewax, waxsemivolatiles, semivolatilesinferno, infernobioethanol, bioethanolwaxplus, waxplusstabilwax, stabilwaxffap