Volatile Amine Analysis Using a Zebron™ ZB-624PLUS™ GC Column
Applications | 2018 | PhenomenexInstrumentation
Volatile amines are critical residual solvents in pharmaceutical manufacturing due to their strong odor and potential toxicity. Accurate, sensitive analysis is essential to ensure compliance with regulatory exposure limits.
The Zebron ZB-624PLUS GC column offers an optimized solution for volatile amine analysis, combining superior deactivation, high sensitivity, and reproducible symmetric peaks that outperform existing 624 phase columns.
No external references were cited in this application note.
GC, GC columns, Consumables
IndustriesPharma & Biopharma
ManufacturerPhenomenex
Summary
Importance of the Topic
Volatile amines are critical residual solvents in pharmaceutical manufacturing due to their strong odor and potential toxicity. Accurate, sensitive analysis is essential to ensure compliance with regulatory exposure limits.
Objectives and Study Overview
- Evaluate the performance of the Zebron ZB-624PLUS GC column for quantifying volatile amines.
- Compare chromatographic behavior and sensitivity against competing 624 phase columns.
Methodology and Instrumentation
- Analytes: Isopropylamine, diethylamine, and triethylamine tested at concentrations from 50 to 500 ppm.
- Instrumentation and Conditions:
- Column: Zebron ZB-624PLUS (30 m × 0.32 mm ID × 1.80 µm film).
- Injection: Split ratio 20:1, 1 µL at 200 °C, using a PLUS Straight Z-Liner™.
- Carrier Gas: Helium at 1.8 mL/min (constant flow).
- Oven Program: 50 °C for 1 min, ramp to 200 °C at 20 °C/min, hold for 5 min.
- Detector: Flame ionization detector at 250 °C.
- Comparative columns (Restek Rxi-624Sil MS and Agilent DB-624UI) run under identical conditions.
Main Results and Discussion
- ZB-624PLUS column delivered symmetric peak shapes for all amines with skew values between 1.0 and 1.3 at 500 ppm.
- Comparisons showed significant tailing and reduced sensitivity on alternative 624 phases, while ZB-624PLUS maintained sharp, high-intensity peaks.
- At trace levels (50–100 ppm), the superior deactivation preserved peak symmetry, enabling reliable low-level quantitation.
Benefits and Practical Applications
- Ensures precise measurement of residual amines in active pharmaceutical ingredients.
- Improves analytical robustness by minimizing analyte-column interactions.
- Supports regulatory compliance with low-bleed, high-thermal stability operation up to 320 °C.
Future Trends and Applications
- Integration with headspace and GC-MS workflows for automated trace detection.
- Development of inert column chemistries tailored for other active compound classes.
- Extension into environmental monitoring and food safety testing for volatile amines.
Conclusion
The Zebron ZB-624PLUS GC column offers an optimized solution for volatile amine analysis, combining superior deactivation, high sensitivity, and reproducible symmetric peaks that outperform existing 624 phase columns.
References
No external references were cited in this application note.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Phenomenex ZB-624PLUS
2018|Phenomenex|Brochures and specifications
ZB-624PLUS ™ • Enhanced Peak Shape with Superior Deactivation • Increased Sensitivity for High Boiling Solvents • Extremely Low Bleed for GC-MS • High Temperature Stability (300/320 °C) The Next Generation of GC Inertness www.phenomenex.com/zb624plus Get to Know the Zebron™…
Key words
phenomenex, phenomenexzebron, zebronplus, plusinert, inertbleed, bleedmin, minstraight, straightliner, linerresidual, residualtaper, tapershape, shapeliners, linerssolvents, solventsinertness, inertnesssystems
Zebron PLUS GC Columns - Improved Inertness, Better Peak Shape, Low Bleed, and Aqueous Stability
2019|Phenomenex|Brochures and specifications
Zebron PLUS GC Columns Improved Inertness, Better Peak Shape, Low Bleed, and Aqueous Stability ™ G C C o lu mns ZB-1plus ZB-5plus ZB-5MSplus ZB-624plus ZB-WAXplus ™ ™ ™ ™ ™ PLUS www.phenomenex.com/GCplus Exceptionally Versatile GC phases PLUS Exceptional Inertness…
Key words
zebron, zebronphenomenex, phenomenexfilter, filterbleed, bleedclick, clickwaxplus, waxplusindicator, indicatorgas, gasmin, mintrap, trapsolvents, solventsplus, pluselectronic, electronicbetter, betterwall
Purgeable Volatile Organic Compounds by GC-MS using Zebron™ ZB-624PLUS™ GC Columns
2018|Phenomenex|Applications
TN-2076 APPLICATION Ramkumar Dhandapani Ph.D. Global Product Manager - GC Purgeable Volatile Organic Compounds by GC-MS using Zebron™ ZB-624PLUS™ GC Columns He has a PhD in Analytical Chemistry and a total of 14 years experience in chromatographic method development and…
Key words
bleed, bleedabundance, abundancezebron, zebronether, etherbutylbenzene, butylbenzenemin, mininjections, injectionsbutyl, butylphenomenex, phenomenexplus, pluspurge, purgetrap, trappce, pcestraight, straighttert
Residual Solvents Testing in Cannabis using Zebron™ ZB-624PLUS™ GC Column
2018|Phenomenex|Applications
APPLICATIONS Residual Solvents Testing in Cannabis using Zebron™ ZB-624PLUS™ GC Column Ramkumar Dhandapani, Zeshan Aqeel, and Allen Misa Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA Overview Cannabis extracts and concentrates contain residual solvents as a result of the…
Key words
cannabis, cannabissolvents, solventsxylene, xylenezebron, zebronresidual, residualphenomenex, phenomenexplus, plusstraight, straightordering, orderingconditions, conditionsliner, linerterms, termsportugal, portugaldimethylformamide, dimethylformamideusa