EST Analytical AS120 GC & GC/MS AUTOSAMPLER
Brochures and specifications | | EST AnalyticalInstrumentation
Automated sample introduction for gas chromatography (GC) and GC–mass spectrometry (MS) is essential to ensure consistent injection volumes, reduce manual errors, and achieve high laboratory throughput. The AS120 autosampler addresses these needs by offering a robust and economical solution.
The AS120 aims to provide reliable and flexible sample handling for a wide range of GC and GC–MS applications across industries such as pharmaceuticals, environmental testing, food and flavors, and petrochemicals. It combines direct syringe injection, dual inlet capability, and customizable tray configurations to meet diverse analytical requirements.
The AS120 GC & GC/MS autosampler includes:
Sample introduction is performed via automated syringes that draw precise aliquots, incorporate programmable air gaps, and deliver consistent injections. The autosampler supports a variety of vial sizes and capacities, from 28 × 40 mL to 120 × 2 mL vials, enabling both high-throughput and specialized workflows.
The AS120 autosampler enhances laboratory productivity by delivering consistent and precise sample introduction. Its versatility makes it well suited for quality control, method development, and routine analysis in pharmaceutical, environmental, food/flavors, and petrochemical sectors.
Advancements may include integration with laboratory information management systems (LIMS), IoT-enabled remote monitoring, and AI-driven scheduling to optimize instrument utilization. Expanding compatibility with novel vial formats and emerging GC techniques will further extend its applicability.
The AS120 GC & GC/MS autosampler offers a cost-effective, reliable, and adaptable platform for automated sample introduction, supporting a wide array of analytical workflows and improving data quality and laboratory efficiency.
GC
IndustriesManufacturerEST Analytical
Summary
Importance of GC Autosampling in Analytical Chemistry
Automated sample introduction for gas chromatography (GC) and GC–mass spectrometry (MS) is essential to ensure consistent injection volumes, reduce manual errors, and achieve high laboratory throughput. The AS120 autosampler addresses these needs by offering a robust and economical solution.
Objectives and Overview
The AS120 aims to provide reliable and flexible sample handling for a wide range of GC and GC–MS applications across industries such as pharmaceuticals, environmental testing, food and flavors, and petrochemicals. It combines direct syringe injection, dual inlet capability, and customizable tray configurations to meet diverse analytical requirements.
Used Instrumentation
The AS120 GC & GC/MS autosampler includes:
- Direct syringe injection with variable fill and injection rates
- Dual inlet support for split and splitless operation
- Air gapping to minimize cross-contamination
- Compatibility with any GC or GC–MS system
Main Methodology
Sample introduction is performed via automated syringes that draw precise aliquots, incorporate programmable air gaps, and deliver consistent injections. The autosampler supports a variety of vial sizes and capacities, from 28 × 40 mL to 120 × 2 mL vials, enabling both high-throughput and specialized workflows.
Main Capabilities and Performance Discussion
- High throughput: up to 120 samples per tray
- Accurate injection volumes and rates for improved reproducibility
- Multiple samples per vial to maximize efficiency
- Use of standard off-the-shelf syringes to reduce operational costs
Benefits and Practical Applications
The AS120 autosampler enhances laboratory productivity by delivering consistent and precise sample introduction. Its versatility makes it well suited for quality control, method development, and routine analysis in pharmaceutical, environmental, food/flavors, and petrochemical sectors.
Future Trends and Potential Applications
Advancements may include integration with laboratory information management systems (LIMS), IoT-enabled remote monitoring, and AI-driven scheduling to optimize instrument utilization. Expanding compatibility with novel vial formats and emerging GC techniques will further extend its applicability.
Conclusion
The AS120 GC & GC/MS autosampler offers a cost-effective, reliable, and adaptable platform for automated sample introduction, supporting a wide array of analytical workflows and improving data quality and laboratory efficiency.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
EST Analytical FLEX ROBOTIC SAMPLING PLATFORM
|EST Analytical|Brochures and specifications
FLEX ROBOTIC SAMPLING PLATFORM The easiest software interface you’ll ever use • User friendly drag-and-drop functionality • No expensive software upgrades to purchase • Maximize GC productivity through overlapping prep routines • Simplified menu options that can be easily edited…
Key words
fiber, fiberroutines, routinesflex, flexspme, spmeyou’ll, you’lleasiest, easiestsyringe, syringeheadspace, headspaceoption, optionrobotic, roboticever, eversweep, sweepstation, stationtray, trayconsisting
EST Analytical CENTURION PURGE & TRAP AUTOSAMPLER
|EST Analytical|Brochures and specifications
CENTURION PURGE & TRAP AUTOSAMPLER The most reliable VOC autosampler on the market today • IS 3% RSD • No vial movement for water samples • No lost vial, syringe or elevator errors • Separate processing area for water and…
Key words
centurion, centurionsoil, soilvial, vialwater, waterprocessing, processingautosampler, autosamplermovement, movementsamples, sampleslost, lostvoc, voctoday, todaysensor, sensormarket, marketoptical, opticaleliminate
EST Analytical EVOLUTION PURGE AND TRAP CONCENTRATOR
|EST Analytical|Brochures and specifications
EVOLUTION PURGE AND TRAP CONCENTRATOR The most reliable VOC concentrator on the market today • Superior moisture control (patented feature) • Low carryover (patented feature) • Easy maintenance & diagnostics • Best in-class service & support • 3 year warranty…
Key words
eliminator, eliminatormultiport, multiportmort, mortpurge, purgesparging, spargingevolution, evolutionconcentrator, concentratortrap, trapventto, venttopatented, patentedgas, gasanalytical, analyticalvalve, valvesparge, spargeline
Analysis of Aroma Compounds in White Wines Using Solid Phase Micro Extraction
|EST Analytical|Applications
Solid Phase Micro Extraction of Flavor Compounds in Beer ANNE JUREK Analysis of Aroma Compounds in White Wines Using Solid Phase Micro Extraction Application Note Food/Flavor Author Abstract: Anne Jurek Applications Chemist EST Analytical Cincinnati, OH Every wine has a…
Key words
pineapple, pineapplearoma, aromafiber, fiberethyl, ethyldesorbtion, desorbtioncaproate, caproateextraction, extractionsour, sourjurek, jurekanne, annecheese, cheeseacid, acidagitation, agitationapple, applealcohol