From ppt to high Levels of Residual Solvents in Food Packaging through HS-GC-FID
Applications | | DANI InstrumentsInstrumentation
Food packaging plays a critical role in preserving product quality, safety and shelf life. However, residual solvents used during the production of polymeric films and coatings can migrate into foodstuffs, posing potential health hazards. Regulatory standards set strict limits for these contaminants, making reliable and sensitive analytical methods essential for industry compliance and consumer protection.
The main objective of this study was to demonstrate a rapid, robust and fully automated approach for the quantitation of residual solvents in food packaging materials. The work presents the use of static headspace sampling combined with fast gas chromatography and flame ionization detection (HS-GC-FID) to achieve low detection limits, high reproducibility and short analysis times suitable for routine quality control.
Packaging samples (50 cm2) were conditioned in sealed 20 mL vials at 100 °C for one hour. Static headspace extraction was performed at 125 °C with a 30 min equilibration period. Multiple headspace extraction (MHE) was applied for solid matrices to correct for incomplete transfer of analytes. Two standard mixtures were prepared on printer paper supports: Mix 1 (14 common solvents) at 2–20 mg/m2 and Mix 2 (11 ethyl acetate impurities) at 4–30 mg/m2. Calibration factors were derived from repeated injections and logarithmic extrapolation of peak areas.
Calibration curves for both mixtures exhibited excellent linearity (R2 > 0.995). Fast GC temperature programming (40 °C to 170 °C at 4 °C/min) and a shorter capillary column reduced run times by approximately 50 % compared to conventional methods. Real sample analysis of four packaging materials revealed solvent levels generally below 5 mg/m2, except for one case of 1-methoxy-2-propanol exceeding 20 mg/m2. The method demonstrated reproducible quantitation, low detection limits and clear chromatographic resolution of target analytes.
This HS-GC-FID workflow delivers automated sample handling, minimal operator intervention and rapid throughput. It meets regulatory requirements for residual solvent monitoring and is well suited for quality assurance, industrial production control and compliance testing in food packaging laboratories.
Advancements may include coupling headspace sampling to mass spectrometry for enhanced selectivity, integration of miniaturized and multiplexed sampling modules for higher throughput, and development of greener carrier gases or solvent-free extraction techniques. Ongoing improvements in detector technology and data processing will further streamline routine analyses.
The combination of DANI HSS 86.50 Plus static headspace sampling and Master GC fast chromatography with FID offers a reliable, sensitive and time-efficient solution for the determination of residual solvents in food packaging. The method provides accurate quantitation, complies with current legislation and supports industrial quality control demands.
GC, HeadSpace
IndustriesFood & Agriculture
ManufacturerDANI Instruments
Summary
Importance of the Topic
Food packaging plays a critical role in preserving product quality, safety and shelf life. However, residual solvents used during the production of polymeric films and coatings can migrate into foodstuffs, posing potential health hazards. Regulatory standards set strict limits for these contaminants, making reliable and sensitive analytical methods essential for industry compliance and consumer protection.
Goals and Study Overview
The main objective of this study was to demonstrate a rapid, robust and fully automated approach for the quantitation of residual solvents in food packaging materials. The work presents the use of static headspace sampling combined with fast gas chromatography and flame ionization detection (HS-GC-FID) to achieve low detection limits, high reproducibility and short analysis times suitable for routine quality control.
Methodology
Packaging samples (50 cm2) were conditioned in sealed 20 mL vials at 100 °C for one hour. Static headspace extraction was performed at 125 °C with a 30 min equilibration period. Multiple headspace extraction (MHE) was applied for solid matrices to correct for incomplete transfer of analytes. Two standard mixtures were prepared on printer paper supports: Mix 1 (14 common solvents) at 2–20 mg/m2 and Mix 2 (11 ethyl acetate impurities) at 4–30 mg/m2. Calibration factors were derived from repeated injections and logarithmic extrapolation of peak areas.
Used Instrumentation
- Static Headspace Sampler HSS 86.50 Plus (oven and manifold at 125 °C, transfer line at 150 °C)
- Fast Gas Chromatograph Master GC (Supelco Vocol 60 m × 0.25 mm, 1.5 µm column)
- Injector: Split/Splitless at 230 °C, split ratio 1:60
- Carrier Gas: Helium at 1 mL/min
- Detector: FID at 250 °C with 300 Hz data acquisition
Main Results and Discussion
Calibration curves for both mixtures exhibited excellent linearity (R2 > 0.995). Fast GC temperature programming (40 °C to 170 °C at 4 °C/min) and a shorter capillary column reduced run times by approximately 50 % compared to conventional methods. Real sample analysis of four packaging materials revealed solvent levels generally below 5 mg/m2, except for one case of 1-methoxy-2-propanol exceeding 20 mg/m2. The method demonstrated reproducible quantitation, low detection limits and clear chromatographic resolution of target analytes.
Benefits and Practical Applications
This HS-GC-FID workflow delivers automated sample handling, minimal operator intervention and rapid throughput. It meets regulatory requirements for residual solvent monitoring and is well suited for quality assurance, industrial production control and compliance testing in food packaging laboratories.
Future Trends and Opportunities
Advancements may include coupling headspace sampling to mass spectrometry for enhanced selectivity, integration of miniaturized and multiplexed sampling modules for higher throughput, and development of greener carrier gases or solvent-free extraction techniques. Ongoing improvements in detector technology and data processing will further streamline routine analyses.
Conclusion
The combination of DANI HSS 86.50 Plus static headspace sampling and Master GC fast chromatography with FID offers a reliable, sensitive and time-efficient solution for the determination of residual solvents in food packaging. The method provides accurate quantitation, complies with current legislation and supports industrial quality control demands.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
RESIDUAL SOLVENTS IN FOOD PACKAGING DHS Dynamic Headspace Sampler & Static Headspace Sampler Approaches
|DANI Instruments|Applications
RESIDUAL SOLVENTS IN FOOD PACKAGING DHS Dynamic Headspace Sampler & Static Headspace Sampler Approaches APPLICATION NOTE AN_176 Introduction The increased awerness for safe and not contaminated food has led the food safety monitoring to become one of the most important…
Key words
master, masterisopropylacetate, isopropylacetatepropylacetate, propylacetateethylacetate, ethylacetateunknown, unknownheadspace, headspacesampler, sampleramount, amountshs, shsdhs, dhstoluene, tolueneacetone, acetonecyclohexanone, cyclohexanonestatic, staticpackaging
RESIDUAL SOLVENTS IN FOOD PACKAGING Food Packaging Analysis through Dynamic Headspace Sampling
|DANI Instruments|Applications
RESIDUAL SOLVENTS IN FOOD PACKAGING Food Packaging Analysis through Dynamic Headspace Sampling APPLICATION NOTE AN_174 Introduction The contamination caused by the contact of packaging with foodstuffs is a concrete risk for human health and can affect the quality of foodstuff…
Key words
lineare, lineareacetate, acetatepackaging, packagingmaster, masterdhs, dhsbutanol, butanolbuthyl, buthyldani, danicellosolve, cellosolvemigration, migrationstripping, strippingmethyl, methylisobuthyl, isobuthylcyclohexanone, cyclohexanoneresidual
Rapid qualitative and quantitative analysis of residual solvents in food packaging by static headspace coupled to GC-FID/MS
2019|Thermo Fisher Scientific|Applications
APPLICATION NOTE 10689 Rapid qualitative and quantitative analysis of residual solvents in food packaging by static headspace coupled to GC-FID/MS Authors Giulia Riccardino and Cristian Cojocariu Thermo Fisher Scientific, Runcorn, UK Keywords Residual solvents, flexible food packaging, food safety, valve…
Key words
mhe, mhepackaging, packagingresidual, residualacetate, acetatefid, fidacetaldehyde, acetaldehydesolvent, solventsolvents, solventsethyl, ethylfood, foodsalami, salamivial, vialmaterials, materialspressure, pressurestandard
RESIDUAL SOLVENTS IN FOOD PACKAGING Food Packaging Analysis through Static Headspace Sampling
|DANI Instruments|Applications
RESIDUAL SOLVENTS IN FOOD PACKAGING Food Packaging Analysis through Static Headspace Sampling APPLICATION NOTE Introduction The monitoring of packaging materials is becoming one of the most important target in the food industry. The DANI Master SHS Static Headspace Sampler permits…
Key words
shs, shsmaster, masterpackaging, packagingheadspace, headspacestatic, staticflight, flightdani, danifood, foodsampler, sampleracetate, acetateacquisition, acquisitiontime, timetemperature, temperaturerate, ratedeconvolution