AC Fast Refinery Gas Analyzer Separates Inert Gases and C1-C5 Hydocarbons in 20 Minutes
Brochures and specifications | 2007 | PACInstrumentation
The precise and rapid analysis of refinery gas streams is crucial for process control, product quality assurance and regulatory compliance. Fast and reliable characterization of hydrocarbons and impurity profiles supports optimization of downstream processes, enhances safety and reduces operational costs.
This article presents the AC Fast Refinery Gas Analyzer Model 1058 (UOP 539), designed to separate inert gases and C1–C5 hydrocarbons within 20 minutes. It reviews system architecture, analytical performance and practical benefits for refinery and petrochemical applications.
The core instrument combines an Agilent 7890 Series gas chromatograph with electronic pneumatic control (EPC), six capillary columns and three analysis channels. Two thermal conductivity detectors (TCD) and one flame ionization detector (FID) provide complementary sensitivity for permanent gases, light hydrocarbons and sulfur species.
The analyzer conducts simultaneous separations:
Key performance highlights include:
The Fast RGA offers:
Emerging developments will focus on deeper integration with plant digital systems, advanced data analytics and predictive maintenance. Miniaturization and enhanced detector sensitivity may enable multiplexed analysis of trace contaminants. The expansion of on-line monitoring and remote diagnostics will further reduce downtime and improve process safety.
The AC Fast Refinery Gas Analyzer Model 1058 delivers fast, accurate and comprehensive gas analysis in under 20 minutes. Its robust design, flexible sampling options and powerful software suite make it an effective tool for refinery operations, petrochemical quality control and environmental monitoring. Continuous innovation in software integration and detector technology will drive further performance gains.
GC
IndustriesEnergy & Chemicals
ManufacturerAgilent Technologies, PAC
Summary
Importance of the Topic
The precise and rapid analysis of refinery gas streams is crucial for process control, product quality assurance and regulatory compliance. Fast and reliable characterization of hydrocarbons and impurity profiles supports optimization of downstream processes, enhances safety and reduces operational costs.
Objectives and Overview
This article presents the AC Fast Refinery Gas Analyzer Model 1058 (UOP 539), designed to separate inert gases and C1–C5 hydrocarbons within 20 minutes. It reviews system architecture, analytical performance and practical benefits for refinery and petrochemical applications.
Instrumental Setup
The core instrument combines an Agilent 7890 Series gas chromatograph with electronic pneumatic control (EPC), six capillary columns and three analysis channels. Two thermal conductivity detectors (TCD) and one flame ionization detector (FID) provide complementary sensitivity for permanent gases, light hydrocarbons and sulfur species.
Methodology
The analyzer conducts simultaneous separations:
- Channel 1 (FID): C2–C5 hydrocarbons and heavier fractions
- Channel 2 (TCD): hydrogen and helium
- Channel 3 (TCD): oxygen, nitrogen, carbon monoxide, carbon dioxide and hydrogen sulfide
Main Results and Discussion
Key performance highlights include:
- Quantification limits: 0.05% for inert gases, 0.01% for hydrocarbons, 0.1% for H2S
- Compliance with UOP 539 and DIN 51666 methods
- Robustness against corrosive sample components
- Fast sample throughput and high reproducibility
Benefits and Practical Applications
The Fast RGA offers:
- Rapid turnaround to support real-time process decisions
- Broad scope covering refinery overhead gases, fuel gas and recycle streams
- Automated sample shut-off and optional gas/liquid sampling device for leak-free, repeatable injections
- Integrated software (GASXLNC™) for calibration, gas property calculations (ASTM, ISO, GPA standards) and LIMS connectivity
Future Trends and Opportunities
Emerging developments will focus on deeper integration with plant digital systems, advanced data analytics and predictive maintenance. Miniaturization and enhanced detector sensitivity may enable multiplexed analysis of trace contaminants. The expansion of on-line monitoring and remote diagnostics will further reduce downtime and improve process safety.
Conclusion
The AC Fast Refinery Gas Analyzer Model 1058 delivers fast, accurate and comprehensive gas analysis in under 20 minutes. Its robust design, flexible sampling options and powerful software suite make it an effective tool for refinery operations, petrochemical quality control and environmental monitoring. Continuous innovation in software integration and detector technology will drive further performance gains.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Refinery Gas Analyzer - Separates C1 through nC6, C6+ Hydrocarbons and Inert Gases
2019|Agilent Technologies|Brochures and specifications
solid partners proven solutions Refinery Gas Analyzer Separates C1 through nC6, C6+ Hydrocarbons and Inert Gases Isolated Left Side Valve Box for Valves, Columns and Detectors ensures Superior Robustness Applies to a Broad Sample Scope of both Gaseous and Liquefied…
Key words
rga, rgapac, pacgasxlnc, gasxlncaccura, accurashutoff, shutoffoverhead, overheadliquefied, liquefiedlpg, lpgpartners, partnersrating, ratinggas, gasrefinery, refineryhydrogen, hydrogensulfide, sulfidegasxnlc
GAS XLNC™ Software - Designed to Simplify and Standardize Gas Analysis
2013|PAC|Brochures and specifications
Designed to Simplify and Standardize Gas Analysis GAS XLNC Software ™ www.paclp.com Easy to Use Software Designed to Simplify and Standardize Gas Analysis • Includes Extensive Range of Report Options and Calculations • Users can add and customize Calculations to…
Key words
density, densityinferior, inferiormol, molideal, idealreal, realcalculations, calculationscal, caldry, drysat, satsuperior, superiormon, monrga, rgacompressibility, compressibilitypac, packpa
GAS XLNC SOFTWARE
2016|PAC|Brochures and specifications
solid partners proven solutions GAS XLNC SOFTWARE TM Easy to Use Software Designed to Simplify and Standardize Gas Analysis Includes Extensive Range of Report Options and Calculations Users can add and customize Calculations to their Specific Needs High Level of…
Key words
density, densityinferior, inferiormol, molxlnc, xlncideal, idealreal, realcal, caldry, drysat, satsuperior, superiormon, monrga, rgacompressibility, compressibilitypac, paccalculations
Extended Analysis for Refinery Gas and Similar Gaseous Mixtures on the AC HiSpeed RGA
|PAC|Applications
Extended Analysis for Refinery Gas and Similar Gaseous Mixtures on the AC HiSpeed RGA Application Note 0 4 4.5 5 min 12 EthylBenzene m+p-Xylene 23.384 - m-, p- xylene 14 22.341 - ethylbenzene 16 18.719 - Nonane 12.554 - Toluene…
Key words
hispeed, hispeedrga, rgagasxlnc, gasxlncchannel, channelextended, extendedxlnc, xlncpentene, pentenexylene, xylenesubdivided, subdividedallows, allowsxylenes, xylenessoftware, softwarebringing, bringinggrouping, groupingspecialists