CHRONECT® Quantos
Brochures and specifications | 2018 | Axel SemrauInstrumentation
Automated powder dosing plays a crucial role in modern analytical workflows by eliminating manual handling errors, increasing throughput, and ensuring reproducibility in sample preparation. Integrating precise dosing into automated platforms addresses bottlenecks in high-demand laboratories and supports data integrity.
This document introduces the CHRONECT Quantos system, a fully automated powder dosing solution designed to complement sample preparation workflows in analytical laboratories. Developed collaboratively by Axel Semrau, METTLER-TOLEDO, Jüke Systemtechnik, and Trajan Scientific and Medical, the system aims to seamlessly integrate accurate dosing and weighing into existing robotic platforms.
The CHRONECT Quantos workflow employs a multi-dimensional robotic system (CHRONECT Bionic) for powder handling and precise weight determination via METTLER-TOLEDO Quantos technology. Key components include:
Implementation of the CHRONECT Quantos system demonstrated robust performance in automated powder dosing. The integration eliminated manual weighing steps, maintained high accuracy across dosing ranges, and expanded the automated working envelope. The dual robot configurations offered flexibility: a cooperative robot for direct user interaction and an industrial robot for high-throughput applications.
The convergence of advanced robotics and analytical instrumentation foreshadows further developments in digital laboratory automation. Future trends include expanded material compatibility, real-time process monitoring, and AI-driven optimization of sample preparation protocols. The modular CHRONECT Quantos framework can adapt to emerging analytical challenges and throughput demands.
The CHRONECT Quantos system represents a significant advancement in laboratory automation, offering precise, reliable, and scalable powder dosing. Its integration into established robotic workflows enhances data quality and operational efficiency, positioning laboratories to meet growing analytical demands.
No external references were provided in the source document.
Sample Preparation
IndustriesManufacturerAxel Semrau
Summary
Significance of the Topic
Automated powder dosing plays a crucial role in modern analytical workflows by eliminating manual handling errors, increasing throughput, and ensuring reproducibility in sample preparation. Integrating precise dosing into automated platforms addresses bottlenecks in high-demand laboratories and supports data integrity.
Objectives and Overview
This document introduces the CHRONECT Quantos system, a fully automated powder dosing solution designed to complement sample preparation workflows in analytical laboratories. Developed collaboratively by Axel Semrau, METTLER-TOLEDO, Jüke Systemtechnik, and Trajan Scientific and Medical, the system aims to seamlessly integrate accurate dosing and weighing into existing robotic platforms.
Methodology and Instrumentation Used
The CHRONECT Quantos workflow employs a multi-dimensional robotic system (CHRONECT Bionic) for powder handling and precise weight determination via METTLER-TOLEDO Quantos technology. Key components include:
- CHRONECT Bionic cooperative or industrial robot for vial handling
- Quantos Powder Dosing System comprising the Quantos Dosing Module and precision balance
- CHRONECT Robotic XYZ platform with a PAL Autosampler by CTC Analytics
- CHRONOS software for system control and process integration
Main Results and Discussion
Implementation of the CHRONECT Quantos system demonstrated robust performance in automated powder dosing. The integration eliminated manual weighing steps, maintained high accuracy across dosing ranges, and expanded the automated working envelope. The dual robot configurations offered flexibility: a cooperative robot for direct user interaction and an industrial robot for high-throughput applications.
Benefits and Practical Applications
- Enhanced workflow efficiency by automating time-consuming preparation steps
- Reduced potential for human error in powder handling
- Scalable integration with existing XYZ robotic systems
- Investment protection through modular design and software compatibility
Future Trends and Potential Applications
The convergence of advanced robotics and analytical instrumentation foreshadows further developments in digital laboratory automation. Future trends include expanded material compatibility, real-time process monitoring, and AI-driven optimization of sample preparation protocols. The modular CHRONECT Quantos framework can adapt to emerging analytical challenges and throughput demands.
Conclusion
The CHRONECT Quantos system represents a significant advancement in laboratory automation, offering precise, reliable, and scalable powder dosing. Its integration into established robotic workflows enhances data quality and operational efficiency, positioning laboratories to meet growing analytical demands.
References
No external references were provided in the source document.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
CHRONECT® Bionic
2018|Axel Semrau|Brochures and specifications
CHRONECT® Bionic Product Information Product Information CHRONECT® Bionic A new era of laboratory automation At the analytica 2018 Axel Semrau® paved the way for a new era of laboratory automation. CHRONECT® Bionic is a new and to date unique solution…
Key words
bionic, bionicchronect, chronectautomation, automationquantos, quantosrobot, robotdosing, dosingrobotic, roboticpowder, powderxyz, xyzautomated, automatedworking, workingproduct, productacceptance, acceptanceperfect, perfectconsisting
CHRONECT Proteomics Workstation
2017|Axel Semrau|Brochures and specifications
Workstation Product Information Product Information CHRONECT Workstation Proteomics Introduction Automation process The mass-spectrometric identification and quantification requires a prior splitting of the proteins into peptides. This splitting, also known as protein digestion, uses enzymes like the protease trypsin or the…
Key words
chronect, chronectproteomics, proteomicsdigestion, digestionworkstation, workstationsemrau, semraugel, gelaxel, axelmedicine, medicinevacuum, vacuumcentrum, centrumtray, traywithin, withindigest, digestprotein, proteintcep
CHRONECT Workstation MCPD
2018|Bruker|Brochures and specifications
CHRONECT Workstation MCPD Product Information Product Information CHRONECT Workstation MCPD MCPD analysis 3-Monochloropropane-1,2-diol (3-MCPD), 2-monochloropropane-1,3-diol (2-MCPD) and glycidol are known as contaminants in foodstuffs due to manufacturing. MCPD fatty acids may occur during the refinement process of oils and fats…
Key words
mcpd, mcpdchronect, chronectworkstation, workstationdgf, dgfsemrau, semrauaxel, axelanalytics, analyticsproduct, productacceptance, acceptanceoverman, overmanzwagerman, zwagermaninformation, informationchronos, chronoswell, wellaocs
CHRONECT LC-GC CHRONECT Workstation PAH
2018|Bruker|Brochures and specifications
CHRONECT LC-GC CHRONECT Workstation PAH Product information Product information CHRONECT Workstation PAH PAH analytics according to the imPAHct method Polycyclic aromatic hydrocarbons (PAHs) are among the most frequently analyzed contaminants in diverse matrices. The reason for this is the partly…
Key words
chronect, chronectpah, pahimpahct, impahctsemrau, semrauworkstation, workstationaxel, axelevoq, evoqfoodstuff, foodstuffanalytics, analyticsbruker, brukerproduct, productacceptance, acceptancepahs, pahspyrene, pyrenebenzo