New Specialized GC Columns for the Petroleum Industry - Integrated Particle Trap PLOTs - DB-Sulfur SCD
Presentations | 2013 | Agilent TechnologiesInstrumentation
Importance of Topic:
Objectives and Overview:
Methodology and Instrumentation:
Used Instrumentation:
Results and Discussion:
Benefits and Practical Applications:
Future Trends and Opportunities:
Conclusion:
References:
GC, GC columns, Consumables
IndustriesEnergy & Chemicals
ManufacturerAgilent Technologies
Summary
New Specialized GC Columns for Petroleum Industry
Importance of Topic:
- Accurate gas and vapor analysis underpins quality control, environmental compliance and process optimization in petroleum operations.
- Stationary phase shedding can compromise sensitivity, reproducibility and damage detectors in porous layer open tubular (PLOT) columns.
- Trace sulfur detection is critical to prevent corrosion, catalyst poisoning and to meet stringent environmental regulations on fuel sulfur content.
Objectives and Overview:
- Introduce integrated particle trap PLOT (PLOT PT) columns that eliminate phase shedding while preserving selectivity and GC/MS compatibility.
- Present a new DB-Sulfur SCD GC column optimized for inertness and low bleed, enhancing stable, sensitive sulfur detection by sulfur chemiluminescence detection (SCD).
Methodology and Instrumentation:
- Baseline stability tests with flame ionization detector (FID) and mass spectrometer detector (MSD) over repeated temperature and pressure cycles to evaluate detector spikes.
- Selectivity studies comparing retention of light gases, solvents and C1–C4 hydrocarbons on PLOT PT vs standard PLOT columns.
- Lifetime tests: hundreds to thousands of methanol/water injections to assess retention index and plate count stability for PoraPLOT Q, PoraPLOT U, Al2O3, Molsieve 5A PT phases.
- Sulfur compound standards (ppb–ppm) analyzed on DB-Sulfur SCD columns by GC-SCD and FID, monitoring linearity, repeatability, sensitivity and detector tube fouling.
Used Instrumentation:
- Gas chromatographs equipped with capillary flow technology (CFT) splitters.
- Detectors: FID (300 °C), MSD (70 eV, transfer line up to 300 °C), sulfur chemiluminescence detector (SCD) with pulsed or continuous plasma.
- Columns: PLOT PT series (PoraPLOT, PoraBOND, HP-PLOT Q/U, Al2O3/KCl, Molsieve 5A PT) and Agilent J&W DB-Sulfur SCD (G3903-63001/63002/63003/63004).
Results and Discussion:
- PLOT PT columns showed no detector spikes under extreme cycling; FID baseline drift <5 pA, MSD noise <2 × 105 counts, enabling valve switching and GC-MS compatibility.
- Selectivity profiles of gases, solvents and C1–C4 hydrocarbons on PLOT PT were within manufacturing reproducibility compared to non-PT references.
- Lifetime testing (>350–1350 injections) revealed no change in retention index (ΔRI <1 unit) or separation performance across polymeric and inorganic PLOT PT phases.
- DB-Sulfur SCD columns delivered consistent response factors over 20+ injections with no sensitivity loss, SCD tube fouling or regeneration downtime for over six months of use.
- Trace sulfur standards (2–100 ppb on-column) achieved signal-to-noise >3, linearity R2 >0.998 and inter-day RSD <5 % for a range of mercaptans, sulfides, disulfides and thiophenes.
Benefits and Practical Applications:
- PLOT PT columns eliminate labor-intensive trap installations, reduce leak risks and enable reliable gas analysis in QA/QC, petrochemical process control and environmental monitoring.
- DB-Sulfur SCD columns provide robust, equimolar sulfur detection in natural gas odorant analysis, light petroleum liquids and process gas streams, minimizing maintenance costs and downtime.
Future Trends and Opportunities:
- Expansion of trap integration technology to other selective phases for trace VOC and process gas analysis.
- Development of high-throughput, automated sulfur detection workflows coupling DB-Sulfur SCD with multiport sampling systems.
- Integration with advanced data analytics and AI-driven method optimization for real-time process monitoring.
Conclusion:
- Integrated PLOT PT columns and DB-Sulfur SCD columns address key challenges in petroleum industry GC analysis by improving stability, sensitivity and reducing maintenance.
- These innovations support stringent quality, environmental and safety requirements while streamlining laboratory workflows.
References:
- ASTM D5623 – Standard Test Method for Sulfur in Light Petroleum Liquids by Sulfur Chemiluminescence Detection
- ASTM D5504 – Standard Test Method for Determination of Trace Sulfur Compounds in Natural Gas by GC-SCD
- Agilent Technologies Brochure 5991-2977EN – New Specialized GC Columns for the Petroleum Industry
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
New Application Specific Columns
2014|Agilent Technologies|Presentations
New Application Specific Columns Simon Jones GC columns Application Engineer What Columns are New? DB-CLP1 DB-CLP2 Environmental DB-UI 8270D DB-Select 624 UI 467 DB-Sulfur SCD PLOT-PT US Pharmacopeia What are the Benefits? Address specific issues with certain methods Response Tailing…
Key words
plot, plotmin, minscd, scdporabond, porabondbhc, bhcporaplot, poraplotendrin, endrinheptachlor, heptachlorchlordane, chlordaneendosulfan, endosulfancolumns, columnsalumina, aluminasulfur, sulfurmethyl, methylcolumn
Agilent J&W GC Columns for Energy and Chemical Applications
2013|Agilent Technologies|Brochures and specifications
Agilent J&W GC Columns for Energy and Chemical Applications POWER YOUR PRODUCTIVITY AND ENSURE TOP PRODUCT QUALITY AGILENT J&W PLOT PT GC AND DB-SULFUR SCD COLUMNS Ruggedness and reliability to meet your lab’s demands From product quality and safety… to…
Key words
plot, plotscd, scdcolumns, columnsagilent, agilentporabond, porabondsulfur, sulfurtest, testporaplot, poraplotstandard, standardparticle, particlegas, gasinert, inertsulfide, sulfidemethod, methodyour
PLOT Columns Separation Solutions for Light Hydrocarbons & Gases
2021|Agilent Technologies|Presentations
PLOT Columns Separation Solutions for Light Hydrocarbons & Gases Porous Layer Open Tubulars Johan Kuipers Training & Development Sept 2021 1 Webinar Agilent PLOT Columns DE44454.2362731481 Table of Boiling Point Fractions Carbon # C1 C2 C3 C4 C5 C6 C7…
Key words
plot, plotwebinar, webinarcolumns, columnsagilent, agilentporous, porousoxygenates, oxygenatesalumina, aluminaalcohol, alcoholpolymer, polymerparticle, particlehydrocarbons, hydrocarbonspolar, polarether, etherselectivity, selectivitycolumn
GC-SCD Analysis of Fuels and Petrochemicals
2021|Shimadzu|Guides
GC-SCD Analysis of Fuels and Petrochemicals Application Notebook GC-SCD Analysis of Fuels and Petrochemicals Application Notebook There is perhaps no technique more specific, selective, and sensitive for analysis of sulfur compounds than gas chromatography with sulfur chemiluminescence detection (GC-SCD). As…
Key words
sulfur, sulfurthiophene, thiophenesulfide, sulfidescd, scddisulfide, disulfidedbds, dbdsinsulating, insulatinggas, gasbenzene, benzenecompounds, compoundsmercaptan, mercaptanequimolar, equimolarsensitivity, sensitivityarea, areanews