Analysis EPA 625: Chlorinated Pesticides using Direct Injection
Applications | | SCION InstrumentsInstrumentation
Chlorinated pesticides remain a critical environmental concern due to their persistence, bioaccumulation, and potential human health impacts. Regulatory frameworks such as EPA Method 625 require reliable analytical techniques to monitor trace levels of these compounds in water and soil matrices. Rapid, sensitive, and reproducible assays support decision making in environmental protection and public health.
This application note demonstrates the direct injection gas chromatography with flame ionization detection (GC-FID) approach to analyze sixteen chlorinated pesticides. The aim is to assess performance characteristics including resolution, sensitivity, and run time under optimized conditions using a SCION GC-FID instrument.
Ultrapure helium served as carrier gas at a linear velocity of 50 cm/s. Samples of pesticide standards at 200 pg per microliter were injected directly in a 2 microliter volume into a SCION-Pesticide column (60 m x 0.25 mm x 2.5 µm). The oven program increased from 120 to 300 °C at 9 °C per minute. The flame ionization detector was maintained at 300 °C to ensure robust detection.
Under the selected conditions, all sixteen target analytes were resolved with distinct peak retention times. The separation sequence covered isomers of benzene hexachloride, heptachlor and its epoxide, aldrin, dieldrin, endrin and its aldehyde, DDT and its degradation products, and endosulfan isomers plus its sulphate. Chromatograms exhibited sharp peaks, low baseline noise, and reproducible retention, confirming method suitability for trace-level analysis.
Direct injection GC-FID provides a straightforward workflow without the need for sample derivatization or complex extraction steps. The method offers high throughput and minimal carryover, making it ideal for routine screening in environmental laboratories. Its robustness supports compliance testing under EPA 625 and similar regulations across water and soil testing facilities.
Advances in detector sensitivity and column technologies could further reduce detection limits and analysis time. Integration with automated sample preparation and data processing will enhance throughput and reproducibility. The approach may extend to multi-residue analysis including emerging contaminants and complex matrices such as sediments and biota.
The direct injection GC-FID method detailed here efficiently separates and quantifies a suite of chlorinated pesticides with accuracy and reproducibility. Its simplicity and robustness make it a valuable tool for environmental monitoring and regulatory compliance under EPA Method 625.
No external references provided in the application note.
GC, GC columns, Consumables
IndustriesEnvironmental
ManufacturerSCION Instruments
Summary
Significance of the topic
Chlorinated pesticides remain a critical environmental concern due to their persistence, bioaccumulation, and potential human health impacts. Regulatory frameworks such as EPA Method 625 require reliable analytical techniques to monitor trace levels of these compounds in water and soil matrices. Rapid, sensitive, and reproducible assays support decision making in environmental protection and public health.
Study objectives and overview
This application note demonstrates the direct injection gas chromatography with flame ionization detection (GC-FID) approach to analyze sixteen chlorinated pesticides. The aim is to assess performance characteristics including resolution, sensitivity, and run time under optimized conditions using a SCION GC-FID instrument.
Methodology and instrumentation
Ultrapure helium served as carrier gas at a linear velocity of 50 cm/s. Samples of pesticide standards at 200 pg per microliter were injected directly in a 2 microliter volume into a SCION-Pesticide column (60 m x 0.25 mm x 2.5 µm). The oven program increased from 120 to 300 °C at 9 °C per minute. The flame ionization detector was maintained at 300 °C to ensure robust detection.
Main results and discussion
Under the selected conditions, all sixteen target analytes were resolved with distinct peak retention times. The separation sequence covered isomers of benzene hexachloride, heptachlor and its epoxide, aldrin, dieldrin, endrin and its aldehyde, DDT and its degradation products, and endosulfan isomers plus its sulphate. Chromatograms exhibited sharp peaks, low baseline noise, and reproducible retention, confirming method suitability for trace-level analysis.
Benefits and practical applications
Direct injection GC-FID provides a straightforward workflow without the need for sample derivatization or complex extraction steps. The method offers high throughput and minimal carryover, making it ideal for routine screening in environmental laboratories. Its robustness supports compliance testing under EPA 625 and similar regulations across water and soil testing facilities.
Future trends and potential applications
Advances in detector sensitivity and column technologies could further reduce detection limits and analysis time. Integration with automated sample preparation and data processing will enhance throughput and reproducibility. The approach may extend to multi-residue analysis including emerging contaminants and complex matrices such as sediments and biota.
Conclusion
The direct injection GC-FID method detailed here efficiently separates and quantifies a suite of chlorinated pesticides with accuracy and reproducibility. Its simplicity and robustness make it a valuable tool for environmental monitoring and regulatory compliance under EPA Method 625.
References
No external references provided in the application note.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of low ppm levels of ethylene, propylene and methanol in water
|SCION Instruments|Applications
Analysis of low ppm levels of ethylene, propylene and methanol in water AN0041 Application Note SCION GC-FID GC-FID conditions Direct Injector Sample Column Oven Programme Carrier Gas FID 100°C 0.3µL SCION-PLOT Q 25m x 0.53mm x 20µm 35°C (5mins) to…
Key words
scion, scionfid, fidprogramme, programmeinstruments, instrumentsconc, concnetherlands, netherlandsppm, ppminjector, injectordirect, directoven, ovencarrier, carrieridentification, identificationnote, notepeak, peakgas
Analysis of Beer using SCION-WAXMS GC Column
|SCION Instruments|Applications
Analysis of Beer using SCION-WAXMS GC Column Application Note AN0040 SCION GC-HS-FID Headspace Conditions Oven 60°C Sample Loop 60°C Transfer Line 100°C Vial Equib Time 20 minutes Fill Pressure 15psi at 50mL/min Inject Time 0.5 minutes GC-FID conditions S/SL Sample…
Key words
scion, scionisoamyl, isoamylfid, fidethyl, ethylacetate, acetatesulphide, sulphidewaxms, waxmsprogramme, programmeisobutanol, isobutanoloven, oveninstruments, instrumentsacetaldehyde, acetaldehydebeer, beerformate, formatenetherlands
Analysis of Sterols in Butter Fat
|SCION Instruments|Applications
Analysis of Sterols in Butter Fat Application Note AN0054 SCION GC-FID GC-FID conditions Injector On Column Sample 0.8μL Column SCION-5MS 30m x 0.32mm x 0.25µm Oven 115°C (1 min) to 260°C at 9°C/min, 260°C to 290°C at 1.5°C/min Carrier Gas…
Key words
scion, scionfid, fidianosterol, ianosterolcholestane, cholestanestigmastanol, stigmastanolbrassicasterol, brassicasterolcampesterol, campesterolstigmasterol, stigmasterolsitosterol, sitosterolsterols, sterolsbutter, butterinstruments, instrumentscholesterol, cholesterolfat, fatbeta
CFC separation using Porous Polymer Material
|SCION Instruments|Applications
CFC separation using Porous Polymer Material Application Note AN0044 SCION GC-FID GC-FID conditions Injector 250°C, Split Sample 1µL Column SCION-BOND Q 25m x 0.53mm x 10µm Oven Programme 100°C (2mins) to 250°C at 10°C/min Carrier Gas Helium 40kPa FID 250°C…
Key words
scion, scionfid, fidcfc, cfcprogramme, programmeinstruments, instrumentsbutane, butanepentane, pentaneporous, porousnetherlands, netherlandshexane, hexanepolymer, polymerinjector, injectoroven, ovenmaterial, materialcarrier