A Method for the Trace Analysis of 175 Pesticides Using the Agilent Triple Quadrupole GC/MS/MS
Applications | 2009 | Agilent TechnologiesInstrumentation
In food safety and regulatory contexts, monitoring pesticide residues at ultratrace levels is essential to protect human health. Complex crop matrices and low maximum residue limits demand highly sensitive and selective analytical techniques such as GC/MS and GC/MS/MS. This work addresses the need for robust multi-residue methods that can both screen a broad range of contaminants and quantify priority targets reliably.
The study compares three MS strategies for pesticide residue analysis: GC single quadrupole operated in full scan with deconvolution reporting software (DRS) and selected ion monitoring (SIM), and GC triple quadrupole in multiple reaction monitoring (MRM) mode. A total of 175 GC-amenable pesticides were targeted by MRM transitions, while a 927-compound library was screened by DRS. Fruit and vegetable extracts, including carrot and tomato, were analyzed to evaluate sensitivity, selectivity, and maintenance demands.
MRM on the GC/QQQ exhibited an order-of-magnitude improvement in signal-to-noise compared to SIM on the single quadrupole, with detection limits reaching sub-ppb levels for key analytes. In a carrot extract, p,p′-DDE was quantified at 3.7 ppb with SIM but at 1.2 ppb equivalent by MRM with superior S/N and no matrix interferences. Across matrices (apple, cabbage, ginseng, orange, spinach), SIM traces showed increasing background noise, whereas MRM channels remained clean. In tomato with incurred residues, GC/MS/MS identified a chlorothalonil metabolite at 9.3 ppb that was undetected by SIM.
The Agilent 7890A/7000A GC/QQQ platform provides unmatched sensitivity and selectivity for routine quantification of target pesticides at regulatory levels. Complementary use of GC/Q full scan with DRS enables broad screening for over 900 contaminants. Implementing column backflush minimizes maintenance intervals and preserves analytical performance during high-throughput food testing campaigns.
Advances may include expanding MRM transition libraries, automating method translation for diverse GC speed conditions, and integrating AI-driven deconvolution with high-resolution MS. Coupling ultra-fast GC columns and novel inlets to triple quadrupoles could further reduce cycle times while maintaining trace-level quantitation. Enhanced data workflows will streamline compliance monitoring across an ever-growing number of pesticide residues.
A dual-tier workflow combining broad-scope GC/Q screening with Agilent DRS and targeted GC/QQQ MRM analysis achieves comprehensive pesticide residue coverage and ultra-trace quantification. The GC/QQQ significantly outperforms single-quad methods in sensitivity and matrix tolerance. Routine column backflushing ensures consistent performance and minimizes downtime in demanding food safety laboratories.
GC/MSD, GC/MS/MS, GC/SQ, GC/QQQ
IndustriesFood & Agriculture
ManufacturerAgilent Technologies
Summary
Significance of the Topic
In food safety and regulatory contexts, monitoring pesticide residues at ultratrace levels is essential to protect human health. Complex crop matrices and low maximum residue limits demand highly sensitive and selective analytical techniques such as GC/MS and GC/MS/MS. This work addresses the need for robust multi-residue methods that can both screen a broad range of contaminants and quantify priority targets reliably.
Objectives and Study Overview
The study compares three MS strategies for pesticide residue analysis: GC single quadrupole operated in full scan with deconvolution reporting software (DRS) and selected ion monitoring (SIM), and GC triple quadrupole in multiple reaction monitoring (MRM) mode. A total of 175 GC-amenable pesticides were targeted by MRM transitions, while a 927-compound library was screened by DRS. Fruit and vegetable extracts, including carrot and tomato, were analyzed to evaluate sensitivity, selectivity, and maintenance demands.
Methodology and Instrumentation
- Sample Preparation: Modified QuEChERS extraction with toluene or acetonitrile and cleanup using activated carbon for high-load matrices.
- GC/QQQ System: Agilent 7890A GC coupled to 7000A triple quadrupole MS; hot splitless injection of 1 µL; MRM transitions optimized for two quantifier and qualifier ions per pesticide; retention time locking to Agilent pesticide method.
- GC/Q System: Agilent 7890A GC with 5975C single quadrupole MSD; multimode inlet cold splitless injections of 5 µL; data acquired in full scan and SIM modes; full-scan data processed with Agilent DRS and RTL Pesticide and Endocrine Disruptor Database.
- Column Backflushing: Capillary flow devices (two-way splitter or Purged Ultimate Union) used to reverse flow postrun, extending column and source life by eliminating high-boiling matrix components.
Main Results and Discussion
MRM on the GC/QQQ exhibited an order-of-magnitude improvement in signal-to-noise compared to SIM on the single quadrupole, with detection limits reaching sub-ppb levels for key analytes. In a carrot extract, p,p′-DDE was quantified at 3.7 ppb with SIM but at 1.2 ppb equivalent by MRM with superior S/N and no matrix interferences. Across matrices (apple, cabbage, ginseng, orange, spinach), SIM traces showed increasing background noise, whereas MRM channels remained clean. In tomato with incurred residues, GC/MS/MS identified a chlorothalonil metabolite at 9.3 ppb that was undetected by SIM.
Benefits and Practical Applications
The Agilent 7890A/7000A GC/QQQ platform provides unmatched sensitivity and selectivity for routine quantification of target pesticides at regulatory levels. Complementary use of GC/Q full scan with DRS enables broad screening for over 900 contaminants. Implementing column backflush minimizes maintenance intervals and preserves analytical performance during high-throughput food testing campaigns.
Future Trends and Potential Applications
Advances may include expanding MRM transition libraries, automating method translation for diverse GC speed conditions, and integrating AI-driven deconvolution with high-resolution MS. Coupling ultra-fast GC columns and novel inlets to triple quadrupoles could further reduce cycle times while maintaining trace-level quantitation. Enhanced data workflows will streamline compliance monitoring across an ever-growing number of pesticide residues.
Conclusion
A dual-tier workflow combining broad-scope GC/Q screening with Agilent DRS and targeted GC/QQQ MRM analysis achieves comprehensive pesticide residue coverage and ultra-trace quantification. The GC/QQQ significantly outperforms single-quad methods in sensitivity and matrix tolerance. Routine column backflushing ensures consistent performance and minimizes downtime in demanding food safety laboratories.
References
- Anastassiades M, Lehotay SJ, Stajnbaher D, Schenck FJ. J AOAC Int 2003;86:412.
- Lehotay SJ, de Kok A, Hiemstra M, Bodegraven P. J AOAC Int 2005;88:595.
- QuEChERS Web resource.
- Mezcua M, Martínez-Uroz MA, Wylie PL, Fernández-Alba AR. J AOAC Int (accepted).
- Meng CK, Szelewski M. Agilent Technologies Publication 5989-7670EN.
- Wylie PL. Agilent Technologies Publication 5989-5076EN.
- Quimby BD et al. Agilent Technologies Publication 5967-5820E.
- Meng CK. Agilent Technologies Publication 5989-6018EN.
- Wylie PL. Agilent Technologies Publication 5989-6095EN.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Analysis of Multipesticide Residues in Tobacco
2015|Agilent Technologies|Applications
Analysis of Multipesticide Residues in Tobacco The Agilent Triple Quadrupole GC/MS/MS Analyzer for Pesticides in Tobacco Application Note Food Testing & Agriculture Authors Abstract Vivian Xianyu Chen and Andy Zhai A multiple reaction monitoring (MRM) method was developed and evaluated…
Key words
tobacco, tobaccosulfone, sulfonedemeton, demetonhch, hchmethyl, methyldisulfoton, disulfotonpesticides, pesticidessulfoxide, sulfoxidersd, rsdcounts, countsrecovery, recoverymatrix, matrixpesticide, pesticiderelative, relativefenthion
Analysis of 197 Pesticides in Durian by Agilent PAL 3 Autosampler and 7000E Triple Quadrupole GC/MSD
2025|Agilent Technologies|Applications
Application Note Food and Beverage Testing Analysis of 197 Pesticides in Durian by Agilent PAL 3 Autosampler and 7000E Triple Quadrupole GC/MSD Authors Abstract Yufeng Zhang, Feng Gu, and Lay Peng Tan Agilent Technologies, Inc. This application note describes a…
Key words
transition, transitiondurian, durianmethyl, methylpesticide, pesticidematrix, matrixquantifier, quantifierqualifier, qualifiermrm, mrmmrms, mrmsmatched, matchedelut, elutheptachlor, heptachlorethyl, ethylname, namecalibration
Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods
2012|Agilent Technologies|Applications
Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods Application Note Food Safety Authors Abstract Fadwa Al-Taher, Rima Juskelis, Comprehensive detection of pesticides in food matrices requires a combination of Yang Chen, Jack Cappozzo both GC/MS…
Key words
spinosad, spinosadstdev, stdevagilent, agilentmode, moderun, runchlorpyrifos, chlorpyrifosfenpropathrin, fenpropathrinpesticide, pesticiderecovery, recoveryazoxystrobin, azoxystrobinmethoxyfenozide, methoxyfenozidesim, simtebufenozide, tebufenozidedicloran, dicloranthiobencarb
ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER
2016|Agilent Technologies|Applications
ENVIRONMENTAL ANALYSIS ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER Solutions for Your Analytical Business Markets and Applications Programs Authors Indrajit Sen & Dr. Samir Vyas Agilent…
Key words
bhc, bhcphorate, phoratepesticide, pesticideendosulfan, endosulfanlinearity, linearitymarkets, marketsindrajit, indrajitmrm, mrmprograms, programsbusiness, businessinlet, inletspiking, spikingsen, sentemperature, temperatureresidues