GC/MS Fundamentals: What are GC/SQ, TQ, and Q-TOF and When to Use Them?
Presentations | 2019 | Agilent TechnologiesInstrumentation
Essential oils are complex mixtures of volatile compounds widely used in flavors and fragrances. Traces of pesticides in these matrices pose analytical challenges due to high background interferences. Robust screening and quantitation methods are needed to ensure product safety and regulatory compliance.
The study aims to compare three Agilent GC/MS platforms for pesticide analysis:
Using a case study on essential oils (grapefruit, lemon, neroli, orange), the work demonstrates screening, confirmation and quantitation workflows across these systems.
Chromatographic conditions were uniform across platforms, employing an Agilent J&W HP-5ms UI column (15 m × 0.25 mm × 0.25 μm) with mid-column backflush. Injection was splitless at volumes of 1–2 µL. Ion source temperature was 280 °C, quadrupole at 150 °C.
In grapefruit oil screening:
Combining platforms enables comprehensive analysis:
This multi-platform strategy streamlines workflows by leveraging each system's strengths for screening, confirmation and quantitation.
Advances likely to impact GC/MS pesticide analysis include:
The comparison of GC/MSD, GC/TQ and GC/Q-TOF highlights a tiered approach to pesticide analysis in essential oils. Single quadrupole systems excel in general screening, triple quadrupole instruments deliver trace-level quantitation, and Q-TOF platforms enable untargeted discovery and formula confirmation. Adopting a multi-platform workflow ensures robust, flexible and comprehensive pesticide monitoring in complex natural product matrices.
GC/MSD, GC/MS/MS, GC/HRMS, GC/SQ, GC/QQQ, GC/Q-TOF
IndustriesManufacturerAgilent Technologies
Summary
Importance of the Topic
Essential oils are complex mixtures of volatile compounds widely used in flavors and fragrances. Traces of pesticides in these matrices pose analytical challenges due to high background interferences. Robust screening and quantitation methods are needed to ensure product safety and regulatory compliance.
Study Objectives and Overview
The study aims to compare three Agilent GC/MS platforms for pesticide analysis:
- GC/single quadrupole (GC/MSD SQ)
- GC/triple quadrupole with MS/MS (GC/TQ)
- GC/quadrupole time-of-flight (GC/Q-TOF)
Using a case study on essential oils (grapefruit, lemon, neroli, orange), the work demonstrates screening, confirmation and quantitation workflows across these systems.
Methodology and Instrumentation
Chromatographic conditions were uniform across platforms, employing an Agilent J&W HP-5ms UI column (15 m × 0.25 mm × 0.25 μm) with mid-column backflush. Injection was splitless at volumes of 1–2 µL. Ion source temperature was 280 °C, quadrupole at 150 °C.
- GC/MSD SQ: Agilent 5977B system, operates in full scan (35–500 amu) or SIM modes. Provides base peak and extracted ion chromatograms for qualitative and quantitative analysis, with unit mass resolution.
- GC/TQ: Agilent 7010B with HES or 7000 series extractor source. MS/MS enables Multiple Reaction Monitoring (MRM) for high selectivity in complex matrices. Precursor→product ion transitions are optimized for quantitation and confirmation.
- GC/Q-TOF: Agilent 7200/7250 Q-TOF with high-resolution time-of-flight detection. Acquires accurate mass spectra in scan mode, enabling untargeted screening and formula confirmation of unknowns.
Main Results and Discussion
In grapefruit oil screening:
- Pyrimethanil was identified by all platforms. SQ spectral deconvolution yielded a match score of 96, TQ MRM quantitated at 29.4 ng/mL, and Q-TOF confirmed accurate mass fragments within 3.7 ppm.
- Malathion was obscured in SQ full scan but detected and quantified by TQ MRM (1.26 ng/mL) and by Q-TOF accurate mass extracted ion chromatograms (0.17 ppm mass error).
- SQ offers limited selectivity against coeluting matrix ions.
- TQ requires careful MRM transition development and supports a finite number of MRMs per run.
- Q-TOF generates large data files and demands high-performance processing hardware.
Benefits and Practical Applications of the Methods
Combining platforms enables comprehensive analysis:
- GC/MSD provides rapid screening with established spectral libraries.
- GC/TQ offers unparalleled selectivity and sensitivity for trace quantitation in difficult matrices.
- GC/Q-TOF affords accurate mass data for untargeted screening and structural elucidation of unknown compounds.
This multi-platform strategy streamlines workflows by leveraging each system's strengths for screening, confirmation and quantitation.
Future Trends and Potential Applications
Advances likely to impact GC/MS pesticide analysis include:
- Expanded high-resolution accurate mass spectral libraries for rapid identification.
- Enhanced spectral deconvolution and automated workflows powered by machine learning.
- Miniaturized or hyphenated systems to increase throughput and reduce sample requirements.
- Integration of ion mobility separation for additional selectivity.
Conclusion
The comparison of GC/MSD, GC/TQ and GC/Q-TOF highlights a tiered approach to pesticide analysis in essential oils. Single quadrupole systems excel in general screening, triple quadrupole instruments deliver trace-level quantitation, and Q-TOF platforms enable untargeted discovery and formula confirmation. Adopting a multi-platform workflow ensures robust, flexible and comprehensive pesticide monitoring in complex natural product matrices.
References
- Henry AS, Quimby B, Chen K, Westland J. GC/MS Fundamentals: GC/SQ, TQ, and Q-TOF and When to Use Them? Agilent Technologies, July 2019.
- Chen K, Quimby B, Xianyu Chen V. Analysis of Pesticides and Environmental Pollutants in Essential Oils Using Multi-Platform GC/MSD, GC/TQ and GC/Q-TOF. Agilent Technologies Application Note.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Single Quad, Tandem Quad and QTOF Mass Spectrometers: What is Used and When?
2019|Agilent Technologies|Presentations
GC/MS Fundamentals: What are GC/SQ, TQ, and Q-TOF and When to Use Them? Angela Smith Henry, Ph.D. Applications Chemist, GC and MS Supplies, Wilmington, DE Bruce Quimby, Ph.D. Applications Chemist, MSD, Wilmington, DE Kai Chen, Ph.D. Applications Chemist, MSD, Santa…
Key words
technologies, technologiesresearch, researchagilent, agilentonly, onlyuse, useions, ionsion, iontof, tofsource, sourcespectrum, spectrummsd, msdmass, masscollision, collisionunknowns, unknownsoil
Agilent Posters at ASMS 2017
2017|Agilent Technologies|Posters
Agilent Posters at ASMS 2017 AUTOMATION High-throughput (sub-2.5 second) direct injection using a modified RapidFire 365 HTMS system 1Agilent Technologies 2PureHoney Technologies, Inc. Experimental Experimental Modifications to RapidFire plumbing • 10 mL sample loop (between V1 port 2 and 5)…
Key words
discussion, discussionwere, wereresults, resultsanalysis, analysision, ionmass, massneg, negusing, usingexperimental, experimentalvoltage, voltageelectrode, electrodepair, pairdata, datacompounds, compoundstof
7200 Series Q-TOF for GC/MS - A new analytical tool for solving complex analytical problems
2011|Agilent Technologies|Presentations
7200 Series Q-TOF for GC/MS A new analytical tool for solving complex analytical problems June 2011 Page 1 ASMS Conference on Mass Spectrometry and Allied Topics June 5-9, 2011 Colorado Convention Center, Denver, CO 7200 GC/Q-TOF Breakfast Seminar Page 2…
Key words
mass, masstof, tofirm, irmion, ionformula, formuladefect, defectdeconvolution, deconvolutioncentroid, centroidfluorotelomer, fluorotelomeraccurate, accuratephotodegradation, photodegradationsource, sourceresolving, resolvingunknowns, unknownsmatrix
Extracting More Analytes from Complex Samples using Agilent’s GC/TQ and GC/Q-TOF
|Agilent Technologies|Presentations
Extracting More Analytes from Complex Samples using Agilent’s GC/TQ and GC/Q-TOF GC/TQ (Triple Quad): Chin-Kai (Kai) Meng, PhD S Senior Application Chemist C GC/Q-TOF (Quad-Time-of-Flight): Terry L. Sheehan, PhD GC/MS Marketing Manager Extracting More Analytes f from C Complex l…
Key words
tof, tofppm, ppmmass, masstocopherol, tocopherolcentroid, centroidmrm, mrmaccurate, accuratepesticide, pesticidetargets, targetsion, ionformula, formularesolution, resolutionresolving, resolvingdatabase, databasebetter