Agilent 5973, 5975, and 5977 Series GC/MSD Supplies

Others | 2019 | Agilent TechnologiesInstrumentation
GC/MSD, GC/SQ
Industries
Manufacturer
Agilent Technologies

Summary

Importance of Topic


Maintaining uninterrupted performance and sensitivity of gas chromatography–mass spectrometry detectors is essential for laboratories conducting trace-level analyses, routine quality control, and research. A consolidated quick reference for critical consumables and parts helps prevent unplanned downtime and ensures analytical consistency.

Goals and Overview


This guide compiles the most commonly ordered supplies and replacement components for the Agilent 5973, 5975, and 5977 GC/MSD series. Its purpose is to streamline ordering, minimize instrument downtime, and support efficient laboratory workflows.

Instrumentation


The guide is organized by instrument subsystem and supply category:
  • Electron ionization (EI) source supplies: extractor tips, transfer lines, filaments, repellers, lenses, source bodies, and assemblies, with stainless, inert, and extractor source part numbers.
  • Chemical ionization (CI) source supplies and high-efficiency source (HES) components: tip seals, dual filaments, repeller assemblies, lenses, spacers, and complete source bodies and assemblies.
  • MS interface and inlet connections: self-tightening column nuts, ferrules (VG, flexible inert), swaging tools, CFT device fittings, and universal tools for capillary installation.
  • Pump and vacuum supplies: quiet covers, vacuum pump fluids, filter kits, tip seal maintenance kits, ion vacuum gauges, gauge controllers, and replacement gauge tubes.
  • Gas clean filters and cleaning kits: carrier gas and impurity filters for GC/MS, gas purifier cartridges, cleaning cloths, swabs, abrasive sheets, and tuning standards.
  • General tools: torque drivers, Torx and pozidriv screwdrivers, hex drivers, wrenches, ball drivers, and specialized removal tools.
  • Inert flow path solutions: complete inertization components to maintain surface passivity for enhanced sensitivity at trace levels.

Main Results and Discussion


The reference organizes part numbers by instrument series and source type, enabling rapid identification of needed consumables. It highlights differentiated inventories for stainless versus inert source configurations and provides equivalent components for extractor-type sources. Key listings include dual EI/CI filament kits, high-efficiency source assemblies, and complete ion source storage solutions. The interface section covers both short and long ferrules, universal fittings, and specialized tools to ensure leak-free connections.

Benefits and Practical Applications


  • Accelerates procurement of replacement parts, reducing instrument downtime.
  • Supports consistent analytical performance by ensuring the use of correct consumables for specific source types.
  • Facilitates preventive maintenance planning with a comprehensive parts inventory.
  • Enhances laboratory productivity by minimizing ordering complexity.

Future Trends and Potential Applications


Emerging opportunities include integration of IoT-enabled inventory tracking for predictive ordering, advanced surface coatings for next-generation inert flow paths, modular source designs for rapid reconfiguration, and digital parts catalogues with AI-driven selection tools to further reduce downtime.

Conclusion


This quick reference guide serves as an essential resource for laboratory managers, service engineers, and analysts using Agilent 5973, 5975, and 5977 GC/MSD systems. By centralizing part numbers and categorizing supplies by source type and instrument interface, it ensures timely maintenance, reliable performance, and uninterrupted analytical operations.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Agilent GC AND GC/MS - Catalog Consumables and Spare Parts
Buy online: www.agilent.com/chem/store Contact us: www.agilent.com/chem/contactus THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG For more information This information is subject to change without notice. © Agilent Technologies, Inc. 2016 Printed in Canada March 8, 2016 5991-5213EN GC AND GC/MS Your Essential…
Key words
supplies, suppliesagilent, agilentparts, partscrosslab, crosslabdescription, descriptionoem, oemnut, nutinlet, inletliners, linerssepta, septaferrule, ferrulecolumn, columnneedle, needlestick, stickassembly
8890 Gas Chromatography (GC) System with 7693A Automatic Liquid Sampler (Essential Instrument Supplies)
Essential Instrument Supplies Agilent technical experts have compiled a list of recommended supplies that you should consider using with your new instrument in order to keep your lab operational without any disruptions and to achieve optimal performance. 8890 Gas Chromatography…
Key words
recommendation, recommendationintuvo, intuvotop, tophydroinert, hydroinertferrules, ferrulesspecific, specificcolumn, columninlet, inletrecommended, recommendedrough, roughmsds, msdsmanagement, managementliners, linerssepta, septapart
Agilent GC-MS Maintenance: Restek’s Quick Reference Guide
Restek GC Accessories Agilent GC-MS Maintenance: Restek’s Quick Reference Guide • Replacement parts for Agilent ion sources now available. • Optimize performance by upgrading ion source components and electron multipliers. • Restock your ion source cleaning supplies to keep your…
Key words
multipliers, multipliersdescription, descriptionelectron, electronkit, kitcleaning, cleaningsupplies, suppliessource, sourceetp, etptip, tipyour, yourgraphite, graphitevespel, vespelagilent, agilentreplacement, replacemention
Nitrosamines Analysis in Pharmaceuticals - Consumables workflow ordering guide
Nitrosamines Analysis in Pharmaceuticals Using Single Quadrupole GC/MS or Triple Quadrupole GC/MS Consumables workflow ordering guide R1 N N R2 R O 2 R 1 R N N 2 R 1 R O R 2 1 N N N N…
Key words
nitrosamine, nitrosaminenitrosamines, nitrosaminesndma, ndmandea, ndeamylist, mylistfavorite, favoriteneipa, neipandipa, ndipadrug, drugppm, ppmitems, itemsinlet, inletclick, clickreplacement, replacementsupplies
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike