Analysis of Trace Thiophene in Benzene According to ASTM D7011 Using Nexis™ SCD-2030
Applications | 2019 | ShimadzuInstrumentation
Accurate quantification of trace thiophene in benzene is critical due to sulfur compounds’ tendency to form sulfur oxides upon combustion and to poison catalysts. Regulatory standards and quality control in the petrochemical industry demand methods capable of detecting sulfur at low parts-per-billion levels to ensure product purity and operational safety.
This study demonstrates the use of ASTM D7011 for analyzing trace thiophene in benzene employing a next-generation sulfur chemiluminescence detector. The focus is on evaluating sensitivity, linearity, repeatability, and the quantitative capability of the Nexis SCD-2030 system over a concentration range of 10–1000 ppb (v/v).
Standard solutions were prepared by diluting thiophene in thiophene-free benzene from 10 to 1000 ppb. Key instrumental conditions included:
Advances in chemiluminescence detection and automated sampling promise further reductions in sulfur detection limits. Integration with high-throughput GC platforms and enhanced data processing tools will improve efficiency in large-scale operations. Novel detector chemistries may enable simultaneous speciation of multiple sulfur compounds without compromising sensitivity.
The Nexis SCD-2030 system successfully meets ASTM D7011 requirements for trace thiophene analysis in benzene, delivering best-in-class sensitivity, stability, and straightforward linear quantitation down to low ppb levels. This methodology supports robust sulfur monitoring for compliance, catalyst protection, and process optimization in petrochemical laboratories.
GC
IndustriesEnergy & Chemicals
ManufacturerShimadzu
Summary
Significance of the topic
Accurate quantification of trace thiophene in benzene is critical due to sulfur compounds’ tendency to form sulfur oxides upon combustion and to poison catalysts. Regulatory standards and quality control in the petrochemical industry demand methods capable of detecting sulfur at low parts-per-billion levels to ensure product purity and operational safety.
Objectives and Study Overview
This study demonstrates the use of ASTM D7011 for analyzing trace thiophene in benzene employing a next-generation sulfur chemiluminescence detector. The focus is on evaluating sensitivity, linearity, repeatability, and the quantitative capability of the Nexis SCD-2030 system over a concentration range of 10–1000 ppb (v/v).
Methodology and Instrumentation
Standard solutions were prepared by diluting thiophene in thiophene-free benzene from 10 to 1000 ppb. Key instrumental conditions included:
- Gas chromatograph: Nexis GC-2030 with AOC-20i plus autosampler
- Column: SH-Rtx-WAX, 30 m × 0.32 mm I.D., 1 µm film
- Injection: 1 µL split injection (1:5) at 125 °C
- Carrier gas: Helium at 2.00 mL/min (constant flow)
- Oven program: 40 °C for 2 min, ramp 10 °C/min to 100 °C, hold 1 min
- SCD conditions: interface 200 °C, furnace 850 °C; detector gases H2 100 mL/min, N2 10 mL/min, O2 12 mL/min, O3 25 mL/min
Main Results and Discussion
- Chromatograms revealed clear thiophene peaks at concentrations as low as 10 ppb, with minimal interference from residual sulfur in high-purity benzene.
- Retention time and peak area repeatability (RSD) were below 9.5% across six injections, confirming robust precision.
- Signal-to-noise ratio for 10 ppb was 5.37; extrapolation to S/N = 10 indicates a quantitative limit near 18 ppb, surpassing the 25 ppb requirement of ASTM D7011.
- Calibration over 10–1000 ppb exhibited excellent linearity (R² > 0.9999) using actual concentration versus area, simplifying quantitation compared to logarithmic methods.
Benefits and Practical Applications
- Enables precise monitoring of trace thiophene below regulatory thresholds, supporting stringent quality control in petroleum processing.
- Linear calibration based on real values streamlines data analysis in routine laboratory workflows.
- High stability and sensitivity of the SCD system ensure consistent, long-term performance in research and industrial settings.
Future Trends and Opportunities
Advances in chemiluminescence detection and automated sampling promise further reductions in sulfur detection limits. Integration with high-throughput GC platforms and enhanced data processing tools will improve efficiency in large-scale operations. Novel detector chemistries may enable simultaneous speciation of multiple sulfur compounds without compromising sensitivity.
Conclusion
The Nexis SCD-2030 system successfully meets ASTM D7011 requirements for trace thiophene analysis in benzene, delivering best-in-class sensitivity, stability, and straightforward linear quantitation down to low ppb levels. This methodology supports robust sulfur monitoring for compliance, catalyst protection, and process optimization in petrochemical laboratories.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
GC-SCD Analysis of Fuels and Petrochemicals
2021|Shimadzu|Guides
GC-SCD Analysis of Fuels and Petrochemicals Application Notebook GC-SCD Analysis of Fuels and Petrochemicals Application Notebook There is perhaps no technique more specific, selective, and sensitive for analysis of sulfur compounds than gas chromatography with sulfur chemiluminescence detection (GC-SCD). As…
Key words
sulfur, sulfurthiophene, thiophenesulfide, sulfidescd, scddisulfide, disulfidedbds, dbdsinsulating, insulatinggas, gasbenzene, benzenecompounds, compoundsmercaptan, mercaptanequimolar, equimolarsensitivity, sensitivityarea, areanews
Analysis of Thiophene in Benzene: Comparison of FPD(S) and SCD Analyses
2019|Shimadzu|Applications
LAAN-A-GC-E073 Application News Analysis of Thiophene in Benzene: Comparison of FPD(S) and SCD Analyses G308 The detectors chosen for trace analysis of sulfur compounds using gas chromatography are Flame Photometric Detector (FPD(S)) and Sulfur Chemiluminescence Detector (SCD) which offer highly…
Key words
scd, scdfpd, fpddetector, detectorthiophene, thiophenefid, fidsulfur, sulfurμvs, μvsarea, areatrademark, trademarkgas, gascomparison, comparisonbenzene, benzenechemiluminescence, chemiluminescencedetectors, detectorsvalue
Overcoming Challenges of Sulfur Analysis in Natural Gas and Gaseous Fuels
2019|Shimadzu|Applications
WHITEPAPER Analytical and Measuring Instruments Overcoming Challenges of Sulfur Analysis in Natural Gas and Gaseous Fuels Andrew Fornadel, Ph.D., Marketing Manager, Energy & Petrochem ■ Introduction Identification and quantification of sulfur in natural gas is a critical factor in assessing…
Key words
sulfide, sulfidesulfur, sulfurscd, scdbutanethiol, butanethiolnatural, naturalmercaptan, mercaptanspeciation, speciationgaseous, gaseousdisulfide, disulfidegas, gasdimethyl, dimethylethyl, ethylerroneous, erroneousnitrogen, nitrogenbalance
Analysis of Sulfur Compounds in Natural Gas by Nexis™ SCD-2030 According to ASTM D5504
2019|Shimadzu|Applications
LAAN-A-GC-E071 Application News No. Gas Chromatography Analysis of Sulfur Compounds in Natural Gas by Nexis™ SCD-2030 According to ASTM D5504 G306 Varying types and amounts of sulfur-containing compounds are present in gaseous hydrocarbon streams. They contribute to the corrosion of…
Key words
sulfur, sulfursulfide, sulfidegas, gasbutanethiol, butanethiolmercaptan, mercaptancompounds, compoundsnatural, naturalnitrogen, nitrogenindex, indexethyl, ethyldisulfide, disulfidebalance, balancedimethyl, dimethylmethyl, methylthiophene