Discover the Possibilities with Mass Spectrometry Intelligence
Brochures and specifications | 2025 | Agilent TechnologiesInstrumentation
Mass spectrometry remains the gold standard for trace-level analysis across environmental, food safety, pharmaceutical, forensic, and industrial quality control applications. Triple quadrupole GC/MS instruments combine selectivity and sensitivity with quantitative accuracy, enabling laboratories to meet increasingly stringent regulatory and business requirements.
This application overview presents the Agilent 7000E triple quadrupole GC/MS system, focusing on its design goals to enhance daily laboratory productivity through reliable performance, expansive dynamic range, and intelligent diagnostics. The study reviews the system’s development history, key technological innovations, and performance benchmarks for targeted and untargeted analyses.
Key elements of the 7000E GC/TQ methodology and instrument configuration include:
Performance benchmarks of the 7000E GC/TQ demonstrate:
Laboratories benefit from the 7000E GC/TQ through reduced downtime, lower operating costs, and simplified method deployment. Applications range from trace pesticide and PCB quantitation to PAH screening and forensic direct analysis. The combination of intelligent hardware and software accelerates time to results while ensuring data quality and reproducibility.
Emerging directions include expanded use of hydrogen carrier gas to alleviate helium supply challenges, deeper integration of cloud-based and networked data platforms for laboratory informatics, adoption of sustainability initiatives such as net-zero emissions, and further automation of analytical workflows with self-learning instrument diagnostics.
The Agilent 7000E triple quadrupole GC/MS system represents a robust, future-ready platform that addresses modern analytical challenges by coupling advanced ion sources, intelligent diagnostics, and comprehensive software solutions. It empowers laboratories to deliver high confidence results with greater efficiency and environmental responsibility.
GC/MSD, GC/MS/MS, GC/QQQ
IndustriesOther
ManufacturerAgilent Technologies
Summary
Importance of the Topic
Mass spectrometry remains the gold standard for trace-level analysis across environmental, food safety, pharmaceutical, forensic, and industrial quality control applications. Triple quadrupole GC/MS instruments combine selectivity and sensitivity with quantitative accuracy, enabling laboratories to meet increasingly stringent regulatory and business requirements.
Objectives and Study Overview
This application overview presents the Agilent 7000E triple quadrupole GC/MS system, focusing on its design goals to enhance daily laboratory productivity through reliable performance, expansive dynamic range, and intelligent diagnostics. The study reviews the system’s development history, key technological innovations, and performance benchmarks for targeted and untargeted analyses.
Employed Methodology and Instrumentation
Key elements of the 7000E GC/TQ methodology and instrument configuration include:
- Triple quadrupole mass analyzer with hyperbolic gold-coated quartz quadrupoles for high sensitivity and alignment stability
- Inert Plus Extractor EI source and optional JetClean self-cleaning ion source to maintain an uncontaminated ion path
- HydroInert ion source enabling hydrogen carrier gas operation with preserved spectral fidelity
- Capillary Flow Technology for on-column backflushing and extended column life
- Agilent IDP-10 dry scroll pump for oil-free, compact vacuum support
- 360° system readiness check and SWARM autotune for automated performance verification
- MassHunter Acquisition 13.0 software with triggered MRM, dynamic MRM/scan, retention time locking, and eMethods for streamlined workflows
- OpenLab data management integration for secure, centralized, and compliant data handling
Key Results and Discussion
Performance benchmarks of the 7000E GC/TQ demonstrate:
- Stable peak area response over 700 injections for pesticide residues in complex matrices with maintenance limited to routine liner and septum changes
- Broad dynamic ranges with excellent linearity for PCB congeners (0.01–10 000 ppb, R²>0.995) and pesticides (0.5–1 000 ppb, R²>0.995)
- Improved spectral fidelity and peak shapes for hydrogen-sensitive compounds using the HydroInert source with H₂ carrier gas
- Enhanced throughput and retrospective analysis capability with simultaneous dynamic MRM/scan acquisition
- Increased uptime via self-aware diagnostics, early maintenance feedback, and automated autotuning
Benefits and Practical Applications
Laboratories benefit from the 7000E GC/TQ through reduced downtime, lower operating costs, and simplified method deployment. Applications range from trace pesticide and PCB quantitation to PAH screening and forensic direct analysis. The combination of intelligent hardware and software accelerates time to results while ensuring data quality and reproducibility.
Future Trends and Opportunities
Emerging directions include expanded use of hydrogen carrier gas to alleviate helium supply challenges, deeper integration of cloud-based and networked data platforms for laboratory informatics, adoption of sustainability initiatives such as net-zero emissions, and further automation of analytical workflows with self-learning instrument diagnostics.
Conclusion
The Agilent 7000E triple quadrupole GC/MS system represents a robust, future-ready platform that addresses modern analytical challenges by coupling advanced ion sources, intelligent diagnostics, and comprehensive software solutions. It empowers laboratories to deliver high confidence results with greater efficiency and environmental responsibility.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent 7000E triple quadrupole GC/MS
2025|Agilent Technologies|Brochures and specifications
Discover the Possibilities with Mass Spectrometry Intelligence 7000E and 7010C triple quadrupole GC/MS FPO A history of leadership in GC and GC/MS Agilent has over 50 years of leadership in GC and GC/MS. The story of Agilent's leadership in mass…
Key words
hydroinert, hydroinertsource, sourceagilent, agilentyour, yourhydrogen, hydrogenesponses, esponsesfpo, fpoacquisition, acquisitionhelium, heliumcarrier, carrierjetclean, jetcleanself, selfmasshunter, masshunterinert, inerttime
Agilent 5977C GC/MSD
2022|Agilent Technologies|Brochures and specifications
Discover the Possibilities Agilent 5977C GC/MSD A history of leadership in GC and GC/MS Agilent has over 50 years of leadership in GC and GC/MS. The story of Agilent's leadership in mass spectrometry started with the founding of HP back…
Key words
hydroinert, hydroinertsource, sourceagilent, agilentinert, inerthydrogen, hydrogenhelium, heliummsd, msdlibrary, libraryyour, yourcarrier, carrieranalysis, analysisquickprobe, quickprobeself, selfopenlab, openlabfpo
Intelligent Agilent GC/MS/MS (HydroInert Application Compendium)
2023|Agilent Technologies|Guides
Intelligent Agilent GC/MS/MS Conquering Analytical Challenges Application Compendium Table of Contents Introduction 3 Application Notes Pesticides Analysis Hydrogen Carrier Gas for Analyzing Pesticides in Pigmented Foods with GC/MS/MS 4 A Fast and Robust GC/MS/MS Analysis of 203 Pesticides in…
Key words
quadratic, quadraticavg, avglinear, linearhydrogen, hydrogendmrm, dmrmhes, hesbenzo, benzoscan, scanhydroinert, hydroinertinlet, inletacquisition, acquisitionsource, sourcetime, timefluoranthene, fluoranthenematrix
Hydrogen Carrier Gas for Analyzing Pesticides in Pigmented Foods with GC/MS/MS
2023|Agilent Technologies|Applications
Application Note Food & Beverage Testing Hydrogen Carrier Gas for Analyzing Pesticides in Pigmented Foods with GC/MS/MS Authors Abstract Anastasia A. Andrianova, Bruce D. Quimby, and Limian Zhao Agilent Technologies, Inc. This application note describes the key strategies for pesticide…
Key words
quadratic, quadraticlinear, linearhydrogen, hydrogenhes, heshydroinert, hydroinertsource, sourcehelium, heliumcarrier, carrierbhc, bhcstandard, standardtecnazene, tecnazenelimit, limittranslating, translatingsensitivity, sensitivitygas