Analysis of 24 Polar and Non-Polar Volatile Organic Compound (VOCs) Emissions from Stationary Sources by ATD-GCMS

Applications | 2019 | PerkinElmerInstrumentation
GC/MSD, Thermal desorption, GC/SQ
Industries
Environmental
Manufacturer
PerkinElmer

Summary

Importance of the Topic


Volatile organic compounds (VOCs) are major contributors to ground-level ozone and air pollution. Accurate monitoring of VOC emissions from stationary industrial sources is crucial to ensure regulatory compliance and protect public health.

Objectives and Overview of the Study


This study aimed to develop a robust qualitative and quantitative method for the analysis of 24 polar and nonpolar VOCs using thermal desorption coupled with gas chromatography mass spectrometry (TD-GC/MS). The target compounds include small ketones, aliphatics and aromatic hydrocarbons relevant to regulatory emission standards.

Methodology


Standard solutions of 24 VOCs were prepared in HPLC grade methanol at concentrations ranging from 5 to 100 ug/mL. One microliter of each calibration solution was introduced into sorbent tubes for thermal desorption. Method precision was evaluated by spiking six tubes at 5 ug/mL and instrument tuning was verified using a 25 ug/mL 4-bromofluorobenzene standard.

Used Instrumentation


  • PerkinElmer TurboMatrix Thermal Desorption System
  • PerkinElmer Clarus GC/MS with electron ionization
  • Elite-624 capillary column (60 m x 0.32 mm x 1.8 um)

Main Results and Discussion


The total ion chromatogram of a 100 ng standard demonstrated baseline separation of all 24 VOCs. Retention times ranged from 4.9 to 30.8 minutes. Calibration curves constructed over 5–100 ng exhibited excellent linearity with determination coefficients (r2) above 0.998 for all analytes. Method precision, expressed as relative standard deviation, ranged from 1.04 to 4.61 percent. At the lowest calibration level (5 ng), signal-to-noise ratios exceeded 36 to over 1500 depending on the compound, confirming sensitive detection at regulatory reporting limits.

Benefits and Practical Applications


  • Regulatory compliance: Meets or exceeds criteria in EPA Method 18, TO-17 and Chinese HJ 734-2014 standards.
  • Sensitivity: Low nanogram detection limits with high signal response.
  • Efficiency: Direct thermal desorption eliminates solvent extraction steps, reducing sample preparation time.

Future Trends and Potential Applications


Advancements in sorbent materials and GC/MS tuning are expected to further enhance sensitivity and reduce analysis time. Potential extensions include real-time monitoring of complex emission profiles in industrial settings and coupling with high-resolution mass spectrometry for non-targeted VOC screening.

Conclusion


The developed TD-GC/MS protocol provides a fast, sensitive and reliable approach for quantifying polar and nonpolar VOC emissions from stationary sources. The method fulfills stringent regulatory requirements and offers a practical solution for environmental monitoring programs.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Determination of Volatile Organic Compounds (VOCs) in Wallpapers Using ATD-GCMS
APPLICATION Gas Chromatography Authors: Guowei Fu Kira. Yang PerkinElmer, Inc. Shanghai, China Determination of Volatile Organic Compounds (VOCs) in Wallpapers Using ATD-GCMS Introduction Wallpaper is widely used throughout the world as an interior design choice that offers bright colors, rich…
Key words
wallpaper, wallpapertemp, tempchloride, chlorideconcentrator, concentratorwallpapers, wallpapersvocs, vocshold, holdtetrachloroethane, tetrachloroethanedesorb, desorbtrap, traptrichloromethane, trichloromethanexylene, xylenebenzene, benzeneoven, oventoluene
Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17
A P P L I C AT I O N N O T E Gas Chromatography/ Mass Spectrometry Authors: Lee Marotta Tom Kwoka PerkinElmer, Inc. Shelton, CT Miles Snow PerkinElmer, Inc. Woodbridge, ON Stephen Varisco CARO Analytical Services Richmond, BC…
Key words
tube, tubetrap, trapcaro, caroperkinelmer, perkinelmersorbent, sorbenttubes, tubesonto, ontopurge, purgedry, dryconcentrator, concentratorcold, coldtime, timeturbomatrix, turbomatrixmay, maytemp
Analysis of Volatile Organic Compounds in Air by Online TD-GC
APPLICATION Gas Chromatography Authors: Kira. Yang Yong. Xu PerkinElmer, Inc. Shanghai, China Analysis of Volatile Organic Compounds in Air by Online TD-GC Introduction Volatile Organic Compounds (VOCs) have been identified as a major source of air pollution, and as such,…
Key words
high, highlow, lowethyltoluene, ethyltolueneconcentrator, concentratortrap, traphold, holddiethylbenzene, diethylbenzenetemp, tempprecision, precisionxylene, xyleneoven, ovenpentane, pentanevoc, vocair, aircas
Extending the Hydrocarbon Range for the Analysis of Soil Gas Samples Using Automated Thermal Desorption Coupled with Gas Chromatography–Mass Spectrometry
ELECTRONICALLY REPRINTED FROM Volume 34 Number 3 MARCH 2016 2016 www.chromatographyonline.com Extending the Hydrocarbon Range for the Analysis of Soil Gas Samples Using Automated Thermal Desorption Coupled with Gas Chromatography– Mass Spectrometry Extending the Hydrocarbon Range for the Analysis of…
Key words
tube, tubedesorption, desorptiontrap, trapthermal, thermalpolynuclear, polynuclearconcentrator, concentratoronto, ontobreakthrough, breakthroughsoil, soilcompounds, compoundsspiked, spikedsorbents, sorbentstubes, tubeshydrocarbon, hydrocarbongas
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike