Highly sensitive and efficient analysis of aroma components using trapped Headspace GC-MS
Posters | 2025 | Shimadzu | ASMSInstrumentation
Aroma profiling of food products is essential for understanding flavor quality and guiding product development. Volatile compounds in trace amounts can significantly influence overall sensory perception, but conventional static headspace GC-MS often misses low-concentration constituents. Trapped headspace sampling addresses this gap by concentrating volatiles prior to analysis, enabling comprehensive detection of both major and minor aroma components.
This study aimed to compare loop vs. trap modes on a Shimadzu HS-20 NX headspace sampler coupled to a GCMS-QP2020 NX system. By evaluating 3× and 5× sample concentration in trap mode, the work sought to reveal trace aroma compounds that remain undetected under standard conditions and to demonstrate enhanced sensitivity across a broad volatile profile.
Sample Preparation:
Chromatographic Conditions:
Loop mode analysis identified 18 volatile compounds. Trap mode increased identification to 35 compounds by capturing trace volatiles. Key findings include:
These results confirm that trapped headspace sampling significantly improves detection limits without compromising analysis of abundant volatiles.
Trapped headspace GC-MS offers:
Advancements may include integration with high-resolution mass spectrometry, automated multivariate data analysis to correlate chemical profiles with sensory metrics, and expansion into complex matrices such as beverages, spices, and fragrances. Further miniaturization and trap material optimization will enhance portability and selectivity for targeted compounds.
Trapped headspace sampling on the HS-20 NX coupled to GCMS-QP2020 NX enables ultra-sensitive, efficient analysis of food aroma profiles. By concentrating volatiles up to fivefold, the method uncovers trace components otherwise undetectable, supporting more complete characterization of sensory-active compounds.
GC/MSD, GC/MS/MS, GC/QQQ, HeadSpace
IndustriesFood & Agriculture
ManufacturerShimadzu
Summary
Importance of the Topic
Aroma profiling of food products is essential for understanding flavor quality and guiding product development. Volatile compounds in trace amounts can significantly influence overall sensory perception, but conventional static headspace GC-MS often misses low-concentration constituents. Trapped headspace sampling addresses this gap by concentrating volatiles prior to analysis, enabling comprehensive detection of both major and minor aroma components.
Aims and Study Overview
This study aimed to compare loop vs. trap modes on a Shimadzu HS-20 NX headspace sampler coupled to a GCMS-QP2020 NX system. By evaluating 3× and 5× sample concentration in trap mode, the work sought to reveal trace aroma compounds that remain undetected under standard conditions and to demonstrate enhanced sensitivity across a broad volatile profile.
Methodology and Instrumentation
Sample Preparation:
- Weighed 20 mg of food aroma sample into 20 mL vials (three replicates).
- Analyzed in loop mode; trap mode with 3× and 5× concentration using electronic cooling.
Chromatographic Conditions:
- Headspace sampler: Shimadzu HS-20 NX, loop and trap modes.
- Gas chromatograph–mass spectrometer: Shimadzu GCMS-QP2020 NX.
- Column: SH-5 MS capillary, 30 m×0.25 mm×0.25 µm.
- Incubation: 30 min at set temperature; total runtime 50.5 min (20.5 min for GC-MS acquisition).
Main Results and Discussion
Loop mode analysis identified 18 volatile compounds. Trap mode increased identification to 35 compounds by capturing trace volatiles. Key findings include:
- Benzene acetaldehyde, gamma-caprolactone, methyl butyrate and o-guaiacol were detectable only in trap mode.
- Peak areas for major compounds (e.g., butanoic acid, acetic acid) rose by over 350 % with 3× trap concentration and by 520 % with 5×, compared to loop mode.
- Average signal enhancement reached 1 401 % at 3× and 2 518 % at 5× concentration.
These results confirm that trapped headspace sampling significantly improves detection limits without compromising analysis of abundant volatiles.
Benefits and Practical Applications
Trapped headspace GC-MS offers:
- Comprehensive aroma profiling in a single run.
- Ultra-sensitive detection of trace volatiles relevant to flavor quality.
- Streamlined workflow for quality control in food and beverage industries.
Future Trends and Applications
Advancements may include integration with high-resolution mass spectrometry, automated multivariate data analysis to correlate chemical profiles with sensory metrics, and expansion into complex matrices such as beverages, spices, and fragrances. Further miniaturization and trap material optimization will enhance portability and selectivity for targeted compounds.
Conclusion
Trapped headspace sampling on the HS-20 NX coupled to GCMS-QP2020 NX enables ultra-sensitive, efficient analysis of food aroma profiles. By concentrating volatiles up to fivefold, the method uncovers trace components otherwise undetectable, supporting more complete characterization of sensory-active compounds.
Used Instrumentation
- Shimadzu HS-20 NX Headspace Sampler (loop and trap modes)
- Shimadzu GCMS-QP2020 NX Single Quadrupole Mass Spectrometer
- SH-5 MS Capillary Column (30 m×0.25 mm×0.25 µm)
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Ensuring food safety through the study of potential extractables and leachables in roasted coffee packaging by ultra-sensitive Headspace GC/MS
2024|Shimadzu|Posters
ThP 347 Ensuring food safety through the study of potential extractables and leachables in roasted coffee packaging by ultra-sensitive Headspace GC/MS 1 1 1 1 Ana Caroline Martimiano , Isabela de Oliveira e Silva , Ricardo Tamashiro Reis , Rodrigo…
Key words
coffee, coffeepackaging, packagingleachables, leachablesfood, foodextractables, extractablescompounds, compoundsidentifying, identifyingcorroborated, corroboratedmain, mainmagnified, magnifiedroasted, roastedadvancement, advancementnotable, notablesubtracting, subtractingeven
Ensuring food safety through the study of potential extractables and leachables in roasted coffee packaging by ultra-sensitive Headspace GC/MS 
2024|Shimadzu|Posters
Ensuring food safety through the study of potential extractables and leachables in roasted coffee packaging by ultra-sensitive Headspace GC/MS Ana Caroline Martimiano1, Isabela de Oliveira e Silva1, Ricardo Tamashiro Reis1, Rodrigo Ossamu Saga Kitamura1 Dominika Gruszecka2 (1) Shimadzu do Brasil…
Key words
coffee, coffeepackaging, packagingfood, foodleachables, leachablesextractables, extractablescompounds, compoundsidentifying, identifyingcorroborated, corroboratedmain, mainroasted, roastedmagnified, magnifiedadvancement, advancementnotable, notablesubtracting, subtractingeven
Aroma Component Analysis Using Trapped Headspace (THS) Sampling
2021|Shimadzu|Applications
GC-MS HS-20 NX Trap/GCMS-QP 2020 NX Application News Aroma Component Analysis Using Trapped Headspace (THS) Sampling A. Aono User Benefits An electrically-cooled focusing trap enables higher analyte concentrations and analysis of a wider range of low-boiling-point and high-boiling-point components…
Key words
ths, thssampling, samplingshs, shsacetaldehyde, acetaldehydetrap, trapcooled, cooledelectrically, electricallyethanol, ethanolisobutyraldehyde, isobutyraldehydepentane, pentaneheadspace, headspacearoma, aromatrapped, trappedisovaleraldehyde, isovaleraldehydevial
Highly Sensitive Analysis of Sulfur Compounds in Beer Using the Trap Mode of a Headspace Sampler
2023|Shimadzu|Applications
GC Nexis™ GC-2030/SCD-2030/HS-20 NX Application News Highly Sensitive Analysis of Sulfur Compounds in Beer Using the Trap Mode of a Headspace Sampler Yuto Nakasuji and Akara Hashimoto User Benefits Using the Trap mode of HS-20 NX allows for a…
Key words
yeast, yeasttrap, trapmethylthioacetate, methylthioacetateloop, loopheadspace, headspacemode, modesulfur, sulfurscd, scdnews, newsakara, akaradmts, dmtsnakasuji, nakasujiyuto, yutopotentially, potentiallyhashimoto