Modern analytical laboratories increasingly demand seamless integration between sample preparation and chromatographic analysis. Automated control of preparative steps such as high-pressure dispensing, cartridge exchange and autosampling reduces human error, improves throughput and enhances data reproducibility. Embedding these functions into a unified software environment also supports robust audit trails and compliance with regulatory guidelines.
This document presents the design and implementation of the Clarity Control Module for the R-Biopharm RIDACREST system. The goal is to enable direct communication and synchronized operation of three key components—Spark HPD high-pressure dispenser, Spark ACE automatic cartridge exchanger and Spark Alias autosampler—within the Thermo Scientific™ Clarity chromatography software. Comprehensive guidance covers installation, configuration, method setup, real-time monitoring and reporting.
Integration of sample preparation devices into Clarity was achieved without hardware modifications beyond standard communication cables. Auto-synchronization commands ("Wait for…" statements) allow precise alignment of dispenser cycles, cartridge exchanges and injection marking. Custom naming and reporting features capture firmware versions and sequence parameters in audit-ready method printouts. Built-in troubleshooting routines and communication log files facilitate rapid resolution of errors.
Ongoing development may introduce cloud-based monitoring, remote firmware updates and integration with laboratory information management systems (LIMS). Machine-learning algorithms could optimize mixing protocols and pressure limits on the fly. Extended support for additional detector synchronization and third-party devices will further broaden applicability in QA/QC and research environments.
The Clarity Control Module for R-Biopharm RIDACREST successfully unifies sample preparation and chromatography under one platform. By delivering synchronized control, comprehensive audit trails and flexible programming, it streamlines complex workflows, accelerates throughput and strengthens data integrity across analytical laboratories.
Sample Preparation, Software
IndustriesPharma & Biopharma
ManufacturerDataApex
Summary
Importance of the Topic
Modern analytical laboratories increasingly demand seamless integration between sample preparation and chromatographic analysis. Automated control of preparative steps such as high-pressure dispensing, cartridge exchange and autosampling reduces human error, improves throughput and enhances data reproducibility. Embedding these functions into a unified software environment also supports robust audit trails and compliance with regulatory guidelines.
Study Objectives and Overview
This document presents the design and implementation of the Clarity Control Module for the R-Biopharm RIDACREST system. The goal is to enable direct communication and synchronized operation of three key components—Spark HPD high-pressure dispenser, Spark ACE automatic cartridge exchanger and Spark Alias autosampler—within the Thermo Scientific™ Clarity chromatography software. Comprehensive guidance covers installation, configuration, method setup, real-time monitoring and reporting.
Methodology and Instrumentation
- Hardware setup: Daisy-chain RS-232, LAN or USB linking of spark modules, with optional digital input device for external start signals. Unique device IDs set via front-panel dials ensure proper addressing.
- Digital I/O mapping: Detailed pin assignments provided for each module enable external synchronization or triggering of detectors and other peripherals.
- Software integration: The Clarity Station hosts the RIDACREST Control Module. Users add modules in System Configuration, assign communication ports, define external start and ready signals, then auto-detect connected instruments.
- Method programming: Dedicated tabs guide users in building time-program sequences for ACE and HPD modules. A user-programmable table in the Alias section replaces separate injection, wash, I/O and mixing windows, supporting up to 239 sequential actions.
- Device monitor and service dialogs: Real-time status panels offer direct control (e.g., clamp movement, syringe flushing, valve switching) and access to maintenance functions like initialization, panic stop and firmware diagnostics.
Main Results and Discussion
Integration of sample preparation devices into Clarity was achieved without hardware modifications beyond standard communication cables. Auto-synchronization commands ("Wait for…" statements) allow precise alignment of dispenser cycles, cartridge exchanges and injection marking. Custom naming and reporting features capture firmware versions and sequence parameters in audit-ready method printouts. Built-in troubleshooting routines and communication log files facilitate rapid resolution of errors.
Benefits and Practical Applications
- End-to-end automation of preparative workflows within a single software interface.
- Enhanced data traceability: instrument methods and execution logs are embedded directly in chromatographic records.
- Flexibility to handle immunoaffinity cartridges, high-throughput plates and complex multi-step programs.
- Reduced risk of sample cross-contamination through programmable wash, dispense and dispense-to-waste steps.
- Scalable architecture easily expanded with future R-Biopharm or third-party modules.
Future Trends and Potential Applications
Ongoing development may introduce cloud-based monitoring, remote firmware updates and integration with laboratory information management systems (LIMS). Machine-learning algorithms could optimize mixing protocols and pressure limits on the fly. Extended support for additional detector synchronization and third-party devices will further broaden applicability in QA/QC and research environments.
Conclusion
The Clarity Control Module for R-Biopharm RIDACREST successfully unifies sample preparation and chromatography under one platform. By delivering synchronized control, comprehensive audit trails and flexible programming, it streamlines complex workflows, accelerates throughput and strengthens data integrity across analytical laboratories.
Reference
- DataApex Ltd. R-Biopharm RIDACREST Clarity Control Module manual, Code/Rev. M210/100A, Date 2025-05-12.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Clarity Control Module AGILENT 7890
2024|Agilent Technologies|Manuals
AGILENT 7890 Clarity Control Module ENG Code/Rev.: M144/80C Date: 10/27/2022 DataApex Ltd. Phone: +420 251 013 400 [email protected] www.dataapex.com Petrzilkova 2583/13 158 00 Prague 5 The Czech Republic ® are trademarks of DataApex Ltd. Microsoft ® and Windows TM are…
Key words
clarity, claritytab, tabflow, flowpressure, pressuredialog, dialogmakeup, makeupbead, beadbutton, buttonsets, setstable, tablepostrun, postrunpurge, purgeallows, allowssignal, signalautodetected
Clarity Control Module AGILENT 68XX
2024|Agilent Technologies|Manuals
AGILENT 68XX Clarity Control Module ENG Code/Rev.: M041/80C Date: 10/27/2022 DataApex Ltd. Phone: +420 251 013 400 [email protected] www.dataapex.com Petrzilkova 2583/13 158 00 Prague 5 The Czech Republic ® are trademarks of DataApex Ltd. Microsoft ® and Windows TM are…
Key words
clarity, claritycommunication, communicationdialog, dialoglan, lanbutton, buttontab, tabconnection, connectiondigital, digitalset, setsets, setsconfiguration, configurationhardware, hardwareallows, allowsagilent, agilentparticular
Clarity Control Module HT3X00A
2024|DataApex|Manuals
HT3X00A Clarity Control Module ENG Code/Rev.: M153/100A Date: 2024-12-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and trademarks…
Key words
reception, receptionsyringe, syringerelay, relayoutput, outputplunger, plungerready, readydialog, dialogbeginning, beginningclarity, claritydefault, defaultcontact, contactautosampler, autosamplersets, setsexit, exithardware
Clarity Control Module HTA HT2X00H
2024|DataApex|Manuals
HTA HT2X00H Clarity Control Module ENG Code/Rev.: M169/100B Date: 2024-12-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
reception, receptionplunger, plungerready, readysyringe, syringedialog, dialogclarity, claritybeginning, beginningsampler, samplersynchronization, synchronizationstart, startinjection, injectionautosampler, autosamplersignal, signalsequence, sequencebutton