Clarity Control Module HTA HT4000L
Manuals | 2025 | DataApex | HTAInstrumentation
The integration of an autosampler into a chromatography system significantly enhances laboratory efficiency by automating sample handling, ensuring reproducible injections, and reducing manual errors. The HTA HT4000L autosampler, when controlled via the Clarity Control Module over LAN, serves as a model for modern analytical automation, addressing the growing demand for high-throughput and reliable QA/QC processes in industrial and research laboratories.
This summary reviews the installation, configuration, operational control, and troubleshooting of the HTA HT4000L autosampler within the Clarity chromatography station. The aim is to provide a clear, step-by-step guide to establishing communication between the PC and autosampler, setting up injection methods, monitoring device status, and integrating autosampler parameters into data reports.
The HTA HT4000L autosampler communicates via a LAN connection using either a cross-over or straight Ethernet cable. Clarity software requires the AS Control Module (p/n A26) and a free network port or local switch. Synchronization with non‐controlled devices is enabled through an 8-pin MiniDIN I/O connector. Installation involves configuring the IP address in Clarity’s System Configuration, assigning digital start and ready channels, and specifying synchronization modes (Normal, Normal without Ready, or Normal single Ready). Method parameters are set in Clarity’s Method Setup dialog, covering syringe and loop sizes, fill speed, viscosity delay, solvent wash routines, sample transfer, reagent addition, injection mode, and solvent positions.
Main features include:
By centralizing autosampler control in Clarity, laboratories achieve synchronized workflows, minimize downtime, and maintain consistent injection quality. The method parameters stored with each chromatogram improve traceability and compliance. Digital synchronization options allow precise timing with detectors or other instruments, critical for multi‐dimensional chromatography.
Future developments may include enhanced remote monitoring via IoT, predictive maintenance using diagnostic data, and expanded firmware capabilities supporting lower flow rates and larger syringe volumes. Integration with laboratory information management systems (LIMS) and cloud‐based analytics will further streamline data handling and regulatory reporting.
The HTA HT4000L autosampler, integrated through Clarity’s Control Module, delivers a robust solution for automated sample injection in chromatographic workflows. Clear installation steps, versatile synchronization, and detailed reporting functionalities make it a valuable tool for analytical laboratories seeking improved throughput and data integrity.
Software
IndustriesOther
ManufacturerDataApex
Summary
Significance of the Topic
The integration of an autosampler into a chromatography system significantly enhances laboratory efficiency by automating sample handling, ensuring reproducible injections, and reducing manual errors. The HTA HT4000L autosampler, when controlled via the Clarity Control Module over LAN, serves as a model for modern analytical automation, addressing the growing demand for high-throughput and reliable QA/QC processes in industrial and research laboratories.
Objectives and Study Overview
This summary reviews the installation, configuration, operational control, and troubleshooting of the HTA HT4000L autosampler within the Clarity chromatography station. The aim is to provide a clear, step-by-step guide to establishing communication between the PC and autosampler, setting up injection methods, monitoring device status, and integrating autosampler parameters into data reports.
Methodology and Instrumentation
The HTA HT4000L autosampler communicates via a LAN connection using either a cross-over or straight Ethernet cable. Clarity software requires the AS Control Module (p/n A26) and a free network port or local switch. Synchronization with non‐controlled devices is enabled through an 8-pin MiniDIN I/O connector. Installation involves configuring the IP address in Clarity’s System Configuration, assigning digital start and ready channels, and specifying synchronization modes (Normal, Normal without Ready, or Normal single Ready). Method parameters are set in Clarity’s Method Setup dialog, covering syringe and loop sizes, fill speed, viscosity delay, solvent wash routines, sample transfer, reagent addition, injection mode, and solvent positions.
Key Results and Discussion
Main features include:
- Direct sending and retrieval of autosampler methods to and from the device.
- Comprehensive hardware monitoring via the Device Monitor and Hardware Configuration dialogs, displaying serial number, syringe volume, and module options.
- Automatic inclusion of autosampler settings in injection reports for seamless documentation.
- Troubleshooting support by enabling detailed TCP/IP communication logs through the COMMDRV.INI file.
Benefits and Practical Applications
By centralizing autosampler control in Clarity, laboratories achieve synchronized workflows, minimize downtime, and maintain consistent injection quality. The method parameters stored with each chromatogram improve traceability and compliance. Digital synchronization options allow precise timing with detectors or other instruments, critical for multi‐dimensional chromatography.
Future Trends and Applications
Future developments may include enhanced remote monitoring via IoT, predictive maintenance using diagnostic data, and expanded firmware capabilities supporting lower flow rates and larger syringe volumes. Integration with laboratory information management systems (LIMS) and cloud‐based analytics will further streamline data handling and regulatory reporting.
Conclusion
The HTA HT4000L autosampler, integrated through Clarity’s Control Module, delivers a robust solution for automated sample injection in chromatographic workflows. Clear installation steps, versatile synchronization, and detailed reporting functionalities make it a valuable tool for analytical laboratories seeking improved throughput and data integrity.
References
- DataApex Ltd. HTA HT4000L Clarity Control Module Manual, Code/Rev. M187/100A. 2025-05-12.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Clarity Control Module HT3X00A
2024|DataApex|Manuals
HT3X00A Clarity Control Module ENG Code/Rev.: M153/100A Date: 2024-12-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and trademarks…
Key words
reception, receptionsyringe, syringerelay, relayoutput, outputplunger, plungerready, readydialog, dialogbeginning, beginningclarity, claritydefault, defaultcontact, contactautosampler, autosamplersets, setsexit, exithardware
Clarity Control Module HTA HT1500L
2024|DataApex|Manuals
HTA HT1500L Clarity Control Module ENG Code/Rev.: M231/90C Date: 2024-02-14 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
dialog, dialogwash, washclarity, clarityautosampler, autosamplertab, tabsetup, setuphta, htaset, setconfiguration, configurationready, readyafter, aftermethod, methodpre, preending, endingsending
Clarity Control Module HTA HT2X00H
2024|DataApex|Manuals
HTA HT2X00H Clarity Control Module ENG Code/Rev.: M169/100B Date: 2024-12-13 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
reception, receptionplunger, plungerready, readysyringe, syringeclarity, claritydialog, dialogbeginning, beginningsampler, samplersynchronization, synchronizationstart, startinjection, injectionautosampler, autosamplersignal, signalsequence, sequencebutton
Clarity Control Module HTA 300
2024|DataApex|Manuals
HTA 300 Clarity Control Module ENG Code/Rev.: M139/90C Date: 2024-02-14 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
clarity, clarityvolume, volumegndgc, gndgcwash, washready, readybubble, bubbleinjection, injectionsample, samplereception, receptionwashing, washingcycles, cyclesderivatising, derivatisingsyncro, syncroprewash, prewashstart