Detection of Siloxanes in Silicone Oils by GCxGC-TOFMS
Applications | 2007 | LECOInstrumentation
Silicone oils are essential in industrial and laboratory applications, yet residual siloxane species can affect product performance and analytical reliability. High-resolution separation and accurate identification of these compounds are critical for quality assurance, formulation development, and failure analysis.
This study compared the performance of comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (GC×GC-TOFMS) against conventional one-dimensional GC-MSD for profiling siloxanes in two silicone oils (5 cSt and 20 cSt). The goal was to enhance peak detection, resolution, and identification accuracy.
Silicone oil samples were diluted 1:50 in HPLC-grade n-pentane and injected (1 µL, splitless) into a GC×GC-TOFMS system. The setup comprised an Agilent 6890 GC, a LECO dual-jet thermal modulator, an RTX-5 primary column (30 m × 0.25 mm × 0.25 µm) and a DB-17ms secondary column (1.40 m × 0.10 mm × 0.10 µm). Helium was used as carrier gas at 1.5 mL/min. The TOFMS detector was optimized for a signal-to-noise ratio ≥100, and data processing employed ChromaTOF software with spectral match thresholds and classification regions to exclude column bleed.
GC×GC-TOFMS analysis of the 5 cSt oil detected 119 peaks (S/N ≥500) and the 20 cSt oil revealed 118 peaks, compared to ~22 and ~35 peaks in one-dimensional GC-MSD. Two-dimensional contour plots resolved linear, branched, and cyclic siloxanes that overlapped in 1-D. Deconvolution separated coeluting species—up to four compounds within a single conventional peak. Classification boundaries effectively excluded column bleed, speeding data processing. Standard mass spectral libraries misassigned larger siloxanes, highlighting the need for a custom siloxane reference library.
GC×GC-TOFMS provides enhanced peak capacity, high spectral acquisition rates, and robust deconvolution, enabling comprehensive profiling of complex silicone oil samples. This supports improved quality control, contamination screening, and detailed formulation studies in chemical and materials laboratories.
Development of user-defined siloxane libraries and automated classification algorithms will further refine identification accuracy. Integration with high-resolution mass spectrometers and advanced modulators is expected to increase throughput and quantitative capabilities, broadening applications in polymer analysis, environmental monitoring, and petrochemical research.
The combination of GC×GC separation and TOFMS detection significantly surpasses traditional GC-MSD for siloxane analysis in silicone oils. Its superior resolving power and deconvolution capabilities make it an invaluable tool for detailed characterization of complex mixtures.
GCxGC, GC/MSD, GC/TOF
IndustriesEnergy & Chemicals
ManufacturerAgilent Technologies, LECO
Summary
Significance of the Topic
Silicone oils are essential in industrial and laboratory applications, yet residual siloxane species can affect product performance and analytical reliability. High-resolution separation and accurate identification of these compounds are critical for quality assurance, formulation development, and failure analysis.
Objectives and Study Overview
This study compared the performance of comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (GC×GC-TOFMS) against conventional one-dimensional GC-MSD for profiling siloxanes in two silicone oils (5 cSt and 20 cSt). The goal was to enhance peak detection, resolution, and identification accuracy.
Methodology
Silicone oil samples were diluted 1:50 in HPLC-grade n-pentane and injected (1 µL, splitless) into a GC×GC-TOFMS system. The setup comprised an Agilent 6890 GC, a LECO dual-jet thermal modulator, an RTX-5 primary column (30 m × 0.25 mm × 0.25 µm) and a DB-17ms secondary column (1.40 m × 0.10 mm × 0.10 µm). Helium was used as carrier gas at 1.5 mL/min. The TOFMS detector was optimized for a signal-to-noise ratio ≥100, and data processing employed ChromaTOF software with spectral match thresholds and classification regions to exclude column bleed.
Instrumentation
- LECO Pegasus 4D GC×GC-TOFMS system
- Agilent 6890 gas chromatograph
- LECO dual-jet thermal modulator
- LECO Pegasus IV Time-of-Flight Mass Spectrometer
- RTX-5 primary column (30 m × 0.25 mm × 0.25 µm)
- DB-17ms secondary column (1.40 m × 0.10 mm × 0.10 µm)
Key Results and Discussion
GC×GC-TOFMS analysis of the 5 cSt oil detected 119 peaks (S/N ≥500) and the 20 cSt oil revealed 118 peaks, compared to ~22 and ~35 peaks in one-dimensional GC-MSD. Two-dimensional contour plots resolved linear, branched, and cyclic siloxanes that overlapped in 1-D. Deconvolution separated coeluting species—up to four compounds within a single conventional peak. Classification boundaries effectively excluded column bleed, speeding data processing. Standard mass spectral libraries misassigned larger siloxanes, highlighting the need for a custom siloxane reference library.
Benefits and Practical Applications of the Method
GC×GC-TOFMS provides enhanced peak capacity, high spectral acquisition rates, and robust deconvolution, enabling comprehensive profiling of complex silicone oil samples. This supports improved quality control, contamination screening, and detailed formulation studies in chemical and materials laboratories.
Future Trends and Applications
Development of user-defined siloxane libraries and automated classification algorithms will further refine identification accuracy. Integration with high-resolution mass spectrometers and advanced modulators is expected to increase throughput and quantitative capabilities, broadening applications in polymer analysis, environmental monitoring, and petrochemical research.
Conclusion
The combination of GC×GC separation and TOFMS detection significantly surpasses traditional GC-MSD for siloxane analysis in silicone oils. Its superior resolving power and deconvolution capabilities make it an invaluable tool for detailed characterization of complex mixtures.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Light Crude Oil Fingerprinting from Six Different Global Regions Using GCxGCTOFMS with Structural Classifications to Compare Functional Group Differences
2013|Agilent Technologies|Applications
Light Crude Oil Fingerprinting from Six Different Global Regions Using GCxGCTOFMS with Structural Classifications to Compare Functional Group Differences LECO Corporation; Saint Joseph, Michigan USA Key Words: GCxGC-TOFMS, FAMES, Quantification 1. Introduction The complex nature of crude oil demands analytical…
Key words
classifications, classificationscrude, crudetofms, tofmsfunctional, functionalgcxgc, gcxgcchemical, chemicalnormalized, normalizedlight, lightoil, oildifferences, differencesgroup, groupcompare, compareillustrate, illustratenigerian, nigeriansix
Analysis of Grape Volatiles by Solid Phase Microextraction and Comprehensive Two-Dimensional Gas Chromatography with Time-of-Flight Mass Spectrometry (GCxGC-TOFMS)
2008|Agilent Technologies|Applications
® Analysis of Grape Volatiles by Solid Phase Microextraction and Comprehensive Two-Dimensional Gas Chromatography with Time-of-Flight Mass Spectrometry (GCxGC-TOFMS) LECO Corporation; Saint Joseph, Michigan USA Key Words: GCxGC-TOFMS, SPME, Food and Flavors The aim of this work was to study…
Key words
isomer, isomerester, estergcxgc, gcxgcgrapes, grapesvarietal, varietalindene, indeneacid, acidethyl, ethylbutanoic, butanoicionone, iononehexanoic, hexanoicdodecane, dodecanegrape, grapechromatof, chromatofscience
Using Classifications and Mass Spectral Filtering to Process GCxGC-TOFMS Data for Polychlorinated Biphenyls
2008|LECO|Applications
® Using Classifications and Mass Spectral Filtering to Process GCxGC-TOFMS Data for Polychlorinated Biphenyls LECO Corporation; Saint Joseph, Michigan USA Key Words: GCxGC-TOFMS, Classifications, Scripts, PCB's Due to modulation, most GCxGC peaks are on the order of 50 to 250…
Key words
classifications, classificationstofms, tofmschlorination, chlorinationgcxgc, gcxgcpcb, pcbpcbs, pcbsscripting, scriptinggeographic, geographicscripts, scriptsbiphenyls, biphenylsmodulator, modulatorpolychlorinated, polychlorinatedresided, residedfiltering, filteringspectral
A Beneficial GCxGC-TOFMS Procedure for Environmental Forensic Fingerprinting Utilizing Structural Classifications to Differentiate Light Crude Oils
2013|Agilent Technologies|Posters
A Beneficial GCxGC-TOFMS Procedure for Environmental Forensic Fingerprinting Utilizing Structural Classifications to Differentiate Light Crude Oils John Heim, Joe Binkley, and Liz Humston-Fulmer | LECO Corporation, Saint Joseph, MI USA INTRODUCTION Crude oil fingerprinting and source identification has become a…
Key words
dtic, dticclassifications, classificationscrude, crudetofms, tofmslight, lightgcxgc, gcxgcstructured, structuredfingerprinting, fingerprintinggeographic, geographicarea, areaoil, oilarabian, arabianregions, regionsoils, oilsgrouped