GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

Using Dragon DHA© with Clarity

Others | 2024 | DataApexInstrumentation
Software
Industries
Energy & Chemicals
Manufacturer
DataApex

Summary

Importance of the topic



Automating chromatogram evaluation enhances throughput, reproducibility and data consistency in analytical laboratories. Integrating dedicated deconvolution and peak analysis software with chromatography data systems streamlines workflows, reduces manual interventions and supports quality assurance in industries ranging from environmental monitoring to pharmaceutical research.

Objectives and study overview



This application note demonstrates how to link Dragon II DHA© deconvolution software with Clarity CDS to enable seamless export, processing and reporting of chromatographic data. The primary aim is to define a standardized workflow that leverages PostRun automation in Clarity to trigger Dragon II DHA© analysis without manual file handling.

Methodology and instrumentation



The integration relies on the following setup:
  • Chromatography Data System: Clarity CDS with configured PostRun action.
  • Deconvolution Software: Dragon II DHA© for automated peak identification and quantification.
  • Data Exchange Format: AIA (.cdf) files exported from Clarity.

Typical workflow steps:
  1. Acquire chromatogram in Clarity and adjust integration parameters as needed.
  2. Configure PostRun Settings to export the analysis automatically to AIA format.
  3. Specify Dragon II DHA© parameters: reference .dha file, selected processing mode (AUTO or MANUAL) and integration thresholds.
  4. Launch Dragon II DHA© upon export; review and close each instance if operating in manual mode.

Optional toolbar customization in Clarity can further accelerate the export step by adding a Perform PostRun icon.

Main results and discussion



Implementing this workflow eliminates manual file browsing and reduces transcription errors. AUTO mode enables hands-free processing for large batches, while MANUAL mode allows interactive review when data requires expert confirmation. Adjusting the Peak area reject value in Dragon II DHA© ensures consistency between Clarity’s integration and downstream deconvolution results.

Benefits and practical applications



  • Increased throughput by automating repetitive export and analysis operations.
  • Enhanced data integrity through direct file transfer and standardized parameters.
  • Flexibility to handle both routine batch analyses and specialized investigations.
  • Easy adaptation to various chromatographic methods by updating reference .dha files.


Future trends and potential applications



Further developments may include:
  • Direct API integration between Clarity and Dragon II DHA© to eliminate PostRun file exports.
  • Cloud-based processing for real-time collaborative data review.
  • Enhanced machine learning algorithms for more accurate deconvolution of complex matrices.
  • Integration with laboratory information management systems (LIMS) for full instrument-to-report data traceability.


Conclusion



The described integration provides a robust framework for automating chromatogram export and deconvolution analysis. By combining Clarity CDS’s PostRun capabilities with Dragon II DHA© automation modes, analytical laboratories can achieve higher sample throughput, improved reproducibility and streamlined workflows.

References



  • Dragon II DHA© software documentation and options menu.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Using SIMDIS Expert® 9 (Separation Systems) with Clarity
Using SIMDIS Expert® 9 (Separation Systems) with Clarity The SIMDIS Expert® 9 may be used with Clarity or Clarity Lite software to process the acquired chromatograms according to Simulated Distillation. The acquired chromatograms are exported as AIA (*.cdf) files and…
Key words
program, programexport, exportrun, runtroubles, troublesaia, aiacdf, cdfbatch, batchdefined, definedsettings, settingssimdis, simdiswise, wiseactivate, activateexported, exporteddialog, dialogclarity
Solutions Rename filenames by folder names
Solutions Rename filenames by folder names
2024|Agilent Technologies|Guides
Solutions - Rename filenames by folder names (import AIA from Chemstation) Introduction After exporting chromatograms to AIA (*.cdf) format in Chemstation the files will be exported to the structure organized by chromatograms. To use it for any automatic processing, such…
Key words
folder, folderfile, filebatch, batchexport, exportchemstation, chemstationfilenames, filenamesoutput, outputaia, aiacdf, cdfrename, renamefolders, foldersimport, importnames, namessingle, singleempty
Clarity solution – MS Excel macro for Result Table check
Solution – MS Excel macro for Result Table check Clarity can automatically export a chromatogram after an analysis or when the reprocessing of the chromatogram is finished. This macro will automatically load the exported chromatogram to MS Excel, subsequently format…
Key words
macro, macroexcel, excelclarity, claritydialog, dialoginvoke, invoketrust, trustclicking, clickingmacros, macrosexport, exportcenter, centeronly, onlymenu, menuchromatogram, chromatogramclick, clickfile
Using Validat 5 (iCD) with Clarity
Using Validat 5 (iCD) with Clarity
2022|DataApex|Technical notes
Using Validat 5 (iCD) with Clarity The Validat 5 may be used with Clarity Chromatography Station 3.0 and later to validate Clarity methods in accordance with various guidelines such as DIN, USP and ICH. Communication between Clarity and Validat is…
Key words
validat, validatclarity, clarityimporting, importingsettings, settingsdatasheet, datasheetinterface, interfaceexporting, exportingfrom, fromshort, shortsequence, sequencedescribes, describesoverview, overviewmethods, methodsdata, dataresults
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike