OPS Open Path Air Monitoring System
Brochures and specifications | 2013 | Bruker OpticsInstrumentation
The Open Path Air Monitoring System (OPS) represents a critical advancement in environmental and industrial gas analysis. By employing Fourier-transform infrared spectroscopy (FT-IR) over an open path, the system delivers rapid, continuous, and multi-component detection of gaseous compounds. Its rugged design and remote sensing capability address the growing need for reliable perimeter monitoring, leak detection, and high-precision atmospheric quantification in diverse field settings.
This summary examines the design, performance, and practical applications of the OPS. Key objectives include:
The OPS uses a modulated infrared source and a RockSolid™ interferometer to generate interferograms. A telescope projects IR radiation across an open path to a retroreflector array typically positioned several hundred meters away. The reflected beam returns through the same optics to an MCT detector. Interferogram data are digitally acquired and processed to yield absorbance spectra in the 650–5000 cm–1 range. Spectral rate and resolution settings enable trade-offs between scan speed (up to 5 scans/s) and spectral precision (< 0.5 cm–1 with optional configuration).
Performance evaluation demonstrates:
Applications tested include fence-line monitoring for safety compliance, real-time emissions tracking at industrial sites, leak location and identification, and high-precision atmospheric gas quantification. Discussion highlights the balance between scan speed and spectral resolution for targeted analyte sets.
The OPS offers:
Emerging directions include:
The OPS open path FT-IR system combines high spectral performance with rugged field readiness, enabling reliable, continuous monitoring of complex gas mixtures. Its versatile instrumentation and software ecosystem support a wide range of environmental, safety, and research applications. Ongoing innovations in connectivity, data analytics, and hardware design will further extend its impact in air quality and process monitoring.
No formal literature references were provided in the source material.
FTIR Spectroscopy
IndustriesManufacturerBruker
Summary
Significance of the Topic
The Open Path Air Monitoring System (OPS) represents a critical advancement in environmental and industrial gas analysis. By employing Fourier-transform infrared spectroscopy (FT-IR) over an open path, the system delivers rapid, continuous, and multi-component detection of gaseous compounds. Its rugged design and remote sensing capability address the growing need for reliable perimeter monitoring, leak detection, and high-precision atmospheric quantification in diverse field settings.
Objectives and Study Overview
This summary examines the design, performance, and practical applications of the OPS. Key objectives include:
- Evaluating the spectral capabilities and detection limits of an open path FT-IR platform.
- Describing operational parameters that ensure reliable field deployment.
- Highlighting use cases such as fence-line monitoring, emissions surveillance, and leak detection.
Methodology
The OPS uses a modulated infrared source and a RockSolid™ interferometer to generate interferograms. A telescope projects IR radiation across an open path to a retroreflector array typically positioned several hundred meters away. The reflected beam returns through the same optics to an MCT detector. Interferogram data are digitally acquired and processed to yield absorbance spectra in the 650–5000 cm–1 range. Spectral rate and resolution settings enable trade-offs between scan speed (up to 5 scans/s) and spectral precision (< 0.5 cm–1 with optional configuration).
Used Instrumentation
- RockSolid™ FT-IR interferometer with vibration-insensitive design.
- Air-cooled mid-IR radiation source.
- 305 mm send/receive telescope integrated into a sealed, desiccated housing.
- Retroreflector array (approx. 500 mm diameter) in a NEMA 4 enclosure.
- MCT detector with Stirling cooler; optional detectors available.
- Integrated QA gas cell for line shape verification and calibration checks.
- On-board data acquisition processor with 24-bit A/D conversion and PC-independent control.
- Software suite (OPUS RS/OPS) with access to a library of over 420 reference spectra.
Key Results and Discussion
Performance evaluation demonstrates:
- Spectral coverage from 650 to 5000 cm–1, enabling detection of a broad array of organic and inorganic gases.
- High temporal resolution: up to 4 scans/s at 1 cm–1 resolution and 5 scans/s at 0.5 cm–1 (single-sided mode).
- Wavenumber accuracy better than 0.01 cm–1, supporting precise concentration measurements.
- Robust field performance under vibration and temperature fluctuations, thanks to a permanently aligned interferometer and desiccated enclosure.
Applications tested include fence-line monitoring for safety compliance, real-time emissions tracking at industrial sites, leak location and identification, and high-precision atmospheric gas quantification. Discussion highlights the balance between scan speed and spectral resolution for targeted analyte sets.
Benefits and Practical Applications
The OPS offers:
- Simultaneous multi-component analysis over extended distances without consumables like liquid nitrogen.
- Rapid deployment and minimal maintenance in harsh environments.
- Enhanced safety through continuous fence-line and periphery surveillance.
- Versatility across industrial emissions monitoring, research, and engine exhaust analysis.
Future Trends and Opportunities
Emerging directions include:
- Integration with IoT and cloud platforms for real-time data sharing and remote diagnostics.
- Machine learning algorithms to improve compound identification and concentration predictions.
- Miniaturization of optical and detector modules to enhance portability.
- Expansion of spectral libraries to cover novel industrial chemicals and greenhouse gases.
Conclusion
The OPS open path FT-IR system combines high spectral performance with rugged field readiness, enabling reliable, continuous monitoring of complex gas mixtures. Its versatile instrumentation and software ecosystem support a wide range of environmental, safety, and research applications. Ongoing innovations in connectivity, data analytics, and hardware design will further extend its impact in air quality and process monitoring.
References
No formal literature references were provided in the source material.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
SIGIS 2 scanning imaging remote sensing system
2017|Bruker|Brochures and specifications
SIGIS 2 Long Distance Identification, Visualization and Quantification of Gases Innovation with Integrity F TIR SIGIS 2 The SIGIS 2 is a scanning imaging remote sensing system based on the combination of an infrared spectrometer with a single element detector…
Key words
opus, opusinfrared, infraredbruker, brukervideo, videoemergency, emergencyaccidents, accidentsspectral, spectralimage, imagecamera, camerascene, scenecan, caninterferometer, interferometersurveillance, surveillanceoptics, opticsscanned
MATRIX-MG Series Automated High-Performance Gas Analyzers
2017|Bruker|Brochures and specifications
MATRIX-MG Series Automated High-Performance Gas Analyzers Innovation with Integrity F T-IR MATRIX-MG Series Fully Automated Identification and Quantification MATRIX-MG01 The target gas is measured in a gas cell for high sensitivity compound analysis based on FT-IR spectroscopy. From the obtained…
Key words
gas, gasopus, opusquantification, quantificationhousing, housingoption, optionmatrix, matrixcell, cellprotective, protectivebruker, brukerinterferometer, interferometergases, gasesfast, fastrocksolidtm, rocksolidtmseries, seriespressure
EM27/SUN Series FTIR Remote Sensing analyzer
2018|Bruker|Brochures and specifications
EM 27/SUN Series For Atmospheric Measurements Innovation with Integrity F TIR The new EM27/SUN Series spectrometers Key Features represent FTIR Remote Sensing analyzers CAMTracker controlled SolarTracker dedicated for atmospheric measurements. Portable and easy to set up They quantify gases such…
Key words
camtracker, camtrackersun, sunsolartracker, solartrackeraligned, alignedbruker, brukerdioxide, dioxidepermanently, permanentlyrocksolidtm, rocksolidtmcarbon, carbonftir, ftirremote, remotesystem, systematmospheric, atmospherictcp, tcpour
Remote Sensing High Performance FTIR Systems
2021|Bruker|Brochures and specifications
Remote Sensing High Performance FTIR Systems Innovation with Integrity F TIR Applications ▀ Identification and Quantification of Pollutants and Hazardous Material ▀ High-Precision Quantification of Trace Gases ▀ Cloud Imaging ▀ Air Quality Monitoring ▀ Fenceline Monitoring ▀ Emission Measurement…
Key words
bruker, brukerremote, remotesensing, sensingsurveillance, surveillanceair, airtics, ticstraining, trainingmonitoring, monitoringservice, serviceidentification, identificationretroreflectors, retroreflectorsftir, ftirsecurity, securityinterferometers, interferometershazardous