NITRO-GEN+ Nitrogen Generator

Brochures and specifications |  | OrganomationInstrumentation
Laboratory gases and gas generators
Industries
Manufacturer
Organomation

Summary

Importance of the Topic


Consistent and high-purity nitrogen is a critical requirement in modern analytical laboratories, particularly for sample preparation and LC-MS workflows. Traditional cylinder or liquid sources pose logistical, safety, and cost challenges. On-demand nitrogen generation systems address these limitations by providing a continuous, controlled supply of gas while minimizing hazards associated with high-pressure cylinders and cryogenic liquids.

Objectives and Overview


This document presents key features and performance data for the NITRO-GEN+ Nitrogen Generator (Catalog #NA1935), designed to support up to 100 sample positions in evaporation systems and to serve as a dedicated gas source for LC-MS instruments. The overview highlights the generator’s design goals of purity, flow capacity, operational stability, and user convenience.

Methodology and Instrumentation


The NITRO-GEN+ employs a two-stage compressor arrangement combined with Carbon Molecular Sieve (CMS) technology to separate nitrogen from ambient air. A high-pressure compressor initially pressurizes the air, followed by a low-pressure stage that optimizes throughput and noise levels. The proprietary CMS adsorbent selectively retains oxygen and moisture, delivering nitrogen at purities up to 99% at flows ≤25 L/min and 98% at higher flows. Key operational metrics include:
  • Maximum flow rate: 35 L/min
  • Nitrogen purity: up to 99% (≤25 L/min), 98% (>25 L/min)
  • Dewpoint: –58 °F (–50 °C)
  • Output pressure range: 0–116 psi (0–8 bar)
  • Warm-up time: 20 minutes

Main Results and Discussion


Performance testing confirms that the generator delivers a stable, uninterrupted gas stream suitable for demanding analytical applications. Noise measurements register 55 dBA at one meter, ensuring a low acoustic footprint. The dual-compressor design reduces mechanical stress and extends service intervals, while ambient-temperature gas production eliminates the need for external chillers or cryogenic dewars. Electrical requirements accommodate global laboratory standards (110–120 V/60 Hz and 220–240 V/50 Hz), and the unit’s IP20 and IK08 ratings ensure protection against solid objects and mechanical impact.

Benefits and Practical Applications


The generator’s plug-and-play integration with Organomation evaporators and LC-MS systems streamlines laboratory workflows by:
  • Eliminating cylinder changeovers and associated downtime
  • Enhancing operator safety through low-pressure, ambient-temperature output
  • Reducing operational costs via lower maintenance and extended compressor life
  • Minimizing laboratory noise and vibration

Future Trends and Potential Applications


Next-generation nitrogen generators are expected to further improve energy efficiency, incorporate digital monitoring and remote diagnostics, and reduce physical footprint. Integration with laboratory information management systems (LIMS) and predictive maintenance platforms will enable real-time performance tracking and automated alerts. Advances in adsorbent materials may yield higher purities at increased flow rates and lower operating pressures.

Conclusion


The NITRO-GEN+ Nitrogen Generator (Cat. #NA1935) provides a robust, low-noise, and cost-effective solution for continuous nitrogen supply in analytical laboratories. Its CMS-based separation technology, dual-compressor architecture, and safety-focused design meet the demands of sample preparation and LC-MS operations while reducing environmental and logistical burdens associated with traditional gas delivery methods.

Reference


None provided.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Will a nitrogen gas generator be compatible with my sample concentrator?
Organomation Improve your sample preparation with a nitrogen generator Will a nitrogen gas generator be compatible with my sample concentrator? The short answer is yes, absolutely. Many sample preparation techniques require the use of nitrogen gas, with the most common…
Key words
nitrogen, nitrogengenerator, generatororganomation, organomationgen, gennitro, nitroyour, yourimprove, improvemckenzie, mckenzieair, airpayback, paybackour, oursample, samplecompressors, compressorstanks, tankscompressor
Product catalogue 2020
Product catalogue 2020
2020|Peak Scientific|Brochures and specifications
Your local gas generation partner Product catalogue 2020 A gas generation brand Discover more at www.peakscientific.com Our Promise Our commitment is to provide your laboratory with a reliable gas generation solution that delivers long term value. We achieve this through…
Key words
nitrogen, nitrogenair, airaccreditations, accreditationsgas, gasoutput, outputprecision, precisionhxwxd, hxwxdhydrogen, hydrogendry, dryzero, zerogenerator, generatoruhp, uhpapplications, applicationssolaris, solarisyour
Gas Generators
Gas Generators
2007|Parker Hannifin|Brochures and specifications
Gas Generators Generate High Purity Gas with Reliability and Safety Economical Safe Convenient sigma-aldrich.com/gc  Gas Generators Introduction Laboratory gas generators are a great alternative to gas cylinders. In addition to being a much more sensible source of gas from…
Key words
generators, generatorsdomnick, domnicknitrox, nitroxhunter, hunterair, airhydrogen, hydrogenaldrich, aldrichsigma, sigmaparker, parkerchromgas, chromgasnitrogen, nitrogengas, gaszero, zerocompressors, compressorspurity
Nitrogen Generator Comparison Organomation NITRO-GEN vs. Parker NitroVap
Nitrogen Generator Comparison Organomation NITRO-GEN vs. Parker NitroVap List Price Organomation NITRO-GEN $5-7k Flow Rate Up to 20 L/min Parker NitroVap-1LV and NitroVap-2LV $14-19k NitroVap-1LV: Up to 140 L/min NitroVap-2LV: Up to 287 L/min NitroVap-1LV: 62 L/min NitroVap-2LV: 124 L/min…
Key words
gen, gennitro, nitronitrovap, nitrovaporganomation, organomationparker, parkernitrogen, nitrogenrapidvap, rapidvapgenerator, generatorlabconco, labconcovertex, vertexgenerators, generatorscompressor, compressornegligible, negligiblepaired, pairedpressure
Other projects
LCMS
ICPMS
Follow us
FacebookX (Twitter)LinkedInYouTube
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike