Analysis of all 136 tetra- through octa- polychlorinated dibenzo-pdioxins and dibenzofurans using an Agilent J&W FactorFour VF-Xms GC column
Applications | 2010 | Agilent TechnologiesInstrumentation
Polychlorinated dibenzo-p-dioxins and dibenzofurans are persistent environmental pollutants with significant toxicological impact. Accurate isomer-specific quantitation of the 17 2378-substituted congeners is essential for reliable Toxic Equivalence (TEQ) assessment and regulatory compliance. Traditional dual-column methods are labor-intensive and time-consuming.
The VF-Xms column achieved complete elution of all 136 congeners with clear resolution of 16 out of 17 critical 2378-substituted dioxins and furans. Key findings include:
The high-silicon arylene-modified VF-Xms column offers a robust single-column solution for full-spectrum PCDD/PCDF analysis. It meets stringent regulatory demands for isomer separation and quantitation, streamlining workflows in environmental and industrial laboratories.
GC/MSD, GC/HRMS, GC columns, Consumables
IndustriesEnvironmental
ManufacturerAgilent Technologies
Summary
Analysis of PCDD/PCDF Separation Using VF-Xms GC Column
Significance of the Topic
Polychlorinated dibenzo-p-dioxins and dibenzofurans are persistent environmental pollutants with significant toxicological impact. Accurate isomer-specific quantitation of the 17 2378-substituted congeners is essential for reliable Toxic Equivalence (TEQ) assessment and regulatory compliance. Traditional dual-column methods are labor-intensive and time-consuming.
Objectives and Study Overview
- Establish a single-column GC method using a high-silicon arylene-modified VF-Xms capillary column for comprehensive separation of all 136 tetra- through octa-chlorinated PCDD/PCDF congeners.
- Demonstrate baseline separation of 16 out of 17 toxicologically relevant 2378-substituted isomers without the need for a polar secondary column.
Methodology and Instrumentation
- Column: Agilent J&W FactorFour VF-Xms, 60 m × 0.25 mm, 0.25 µm film thickness.
- Carrier gas: Helium at constant pressure (290 kPa, 42 psi).
- Oven temperature program: 160 °C (1 min); ramp to 230 °C at 35 °C/min (hold 18 min); ramp to 250 °C at 10 °C/min (hold 25 min); ramp to 310 °C at 10 °C/min (hold 6 min).
- Injection: Splitless at 270 °C, 1 µL of 25 ng/mL standard mixture in nonane.
- Detection: MAT-95XP high-resolution magnetic sector MS in SIM mode (>10 000 resolution).
Main Results and Discussion
The VF-Xms column achieved complete elution of all 136 congeners with clear resolution of 16 out of 17 critical 2378-substituted dioxins and furans. Key findings include:
- Baseline separation of 2378-TCDF from co-eluting isomers with valley depths exceeding regulatory requirements (>25%).
- Elution order consistent with predicted retention behavior of non-polar to polar congeners.
- Single-column method delivers quantification accuracy comparable to dual-column protocols.
Benefits and Practical Applications
- Simplified workflow removes the need for column switching or confirmatory analyses, reducing analysis time and operational complexity.
- Enhanced separation reliability supports accurate TEQ calculations for environmental monitoring and compliance testing.
- Method is directly applicable in QA/QC and industrial laboratories for routine PCDD/PCDF surveillance.
Future Trends and Applications
- Development of novel stationary phases to further shorten run times and boost resolution.
- Integration with automated sample preparation and AI-driven data analysis.
- Miniaturized high-resolution GC-MS systems for on-site screening of persistent organic pollutants.
- Expansion of column chemistries to broader classes of chlorinated and brominated contaminants.
Conclusion
The high-silicon arylene-modified VF-Xms column offers a robust single-column solution for full-spectrum PCDD/PCDF analysis. It meets stringent regulatory demands for isomer separation and quantitation, streamlining workflows in environmental and industrial laboratories.
References
- Kuipers J, Fishman VN. Analysis of all 136 tetra- through octa-polychlorinated dibenzo-p-dioxins and dibenzofurans using an Agilent J&W FactorFour VF-Xms GC column. Agilent Technologies Application Note SI-02196, October 2010.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
An Alternate Testing Protocol for EPA 1613B using Agilent Triple Quadrupole GC/MS
2021|Agilent Technologies|Applications
Application Note An Alternate Testing Protocol for EPA 1613B using Agilent Triple Quadrupole GC/MS Determination of 2,3,7,8-substituted tetra- through octa-chlorinated dibenzo-p-dioxins and dibenzofurans Authors Coreen Hamilton and Xinhui Xie, SGS AXYS Analytical Services Ltd. Tarun Anumol, Anastasia Andrianova, and Dale…
Key words
dioxins, dioxinsfurans, furanssgs, sgsaxys, axyspcdfs, pcdfsocdd, ocddpcdd, pcddhrms, hrmspcdf, pcdfocta, octaocdf, ocdfpcdds, pcddsmrm, mrmrrf, rrfchlorinated
Analysis of Dioxins in Environmental Samples using GC/MS - Consumable Workflow Ordering Guide
2021|Agilent Technologies|Guides
Analysis of Dioxins in Environmental Samples using GC/MS Consumable Workflow Ordering Guide 9 8 O 1 2 PCDDs 7 Clx 6 O 3 4 Cly Analysis of Dioxins in Environmental Samples using GC/MS Determination of 2,3,7,8-substituted tetra- through octa-chlorinated dibenzo-p-dioxins…
Key words
dioxins, dioxinsmylist, mylistfurans, furanspolychlorinated, polychlorinatedpcdds, pcddsdibenzofurans, dibenzofuransdibenzo, dibenzototal, totalhrms, hrmsaxys, axyssgs, sgshrgc, hrgcenvironmental, environmentalapproved, approvedhepta
An Inter-Laboratory Evaluation of a Confirmatory Method For Dioxins in Food and Environmental Samples Using APGC-MS/MS
2015|Agilent Technologies|Applications
An Inter-Laboratory Evaluation of a Confirmatory Method For Dioxins in Food and Environmental Samples Using APGC-MS/MS Bert van Bavel,1 Dawei Geng,1 Laura Cherta,2 Jaime Nácher-Mestre,2 Tania Portolés,2 Manuela Abaos Ábalos,1,3 Jordi Sauló,3 Esteban Abad,3 Jody Dunstan,5 Rhys Jones,5 Alexander Kotz,4…
Key words
apgc, apgcdioxins, dioxinsconfirmatory, confirmatorytcdd, tcddinter, interlaboratory, laboratoryevaluation, evaluationhrms, hrmsxevo, xevofood, foodfat, fatpcdd, pcddenvironmental, environmentalsamples, sampleshxcdf
What Else Is In My Dioxin Sample? High Performance Time-Of-Flight Mass Spectral Analysis Of Environmental Samples
2012|LECO|Posters
What Else Is In My Dioxin Sample? High Performance Time-Of-Flight Mass Spectral Analysis Of Environmental Samples Slava Artaev1, Eric J. Reiner2, Peter Gorst-Allman3, Joe Binkley1 , and David E Alonso1 1. LECO Corporation, USA 2. University of Toronto 3. LECO…
Key words
hxcdf, hxcdfhpcdf, hpcdfhxcdd, hxcddocdf, ocdftcdf, tcdfocdd, ocddabundance, abundancepcdf, pcdfmass, masstcdd, tcddobserved, observedtofms, tofmstrue, truenist, nistaccuracy