GCMS
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike

GC Analysis of PAHs using an Agilent J&W FactorFour VF-17ms Column with EZ-Guard

Applications | 2010 | Agilent TechnologiesInstrumentation
GC, GC columns, Consumables
Industries
Environmental, Food & Agriculture
Manufacturer
Agilent Technologies
Key words
Downloadable PDF for viewing
 

Similar PDF

Toggle
Separation of EU and EPA Regulated PAHs on Agilent J&W FactorFour VF-17ms Column Application Note Author Introduction Laura Provoost Agilent Technologies, Inc. The difficulty in analyzing polycyclic aromatic hydrocarbons (PAHs) is the number of PAHs with the same mass. This…
Key words
benzo, benzotriphenylene, triphenylenefluoranthene, fluoranthenepah, pahpahs, pahspyrene, pyreneanthracene, anthraceneresolve, resolveepa, epadifficult, difficultbenz, benzpolycyclic, polycyclicfluorene, fluorenemin, minchrysene
Fast separation of EU and EPA Regulated PAHs on Agilent J&W FactorFour VF-17ms for PAH Application Note Author Introduction Laura Provoost Agilent Technologies, Inc. When analyzing polycyclic aromatic hydrocarbons (PAHs) the bottleneck is the number of PAHs with the same…
Key words
benzo, benzofluoranthene, fluoranthenetriphenylene, triphenylenepahs, pahsanthracene, anthraceneepa, epabenz, benzpah, pahfluorene, fluorenechrysene, chrysenepyrene, pyreneregulated, regulatedprovoost, provoostmin, minenclose
Fast GC Analysis of EPA and EU Regulated PAHs
2010|Agilent Technologies|Applications
Fast GC Analysis of EPA and EU Regulated PAHs Application Note Authors Introduction Johan Kuipers Agilent Technologies, Inc. After assessing 33 PAHs, the European Commission Scientific Committee on Food (SCF) in 2002 found that due to their toxicity, 15 of…
Key words
abundance, abundancemin, minperylene, peryleneanthracene, anthracenebenzo, benzotime, timephenantrene, phenantrenepah, pahpahs, pahscoelution, coelutionghi, ghipairs, pairsambientale, ambientalebardini, bardinicompromizing
PAHs
2011|Agilent Technologies|Applications
PAHs Application Note Environmental Authors Introduction Agilent Technologies, Inc. GC analysis of 16 polyaromatic hydrocarbons according to EPA 610 is achieved in less than 23 minutes using Agilent VF-5ms EZ-Guard columns. Conditions Technique : GC Column : Agilent FactorFour EZ-Guard…
Key words
courtesy, courtesypahs, pahsprinted, printedinjector, injectorusa, usaauthors, authorsprogram, programsize, sizeenvironmental, environmentaltechnique, techniquecarrier, carrieridentification, identificationpressure, pressuresolvent, solventdetector
Other projects
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike