Agilent 990 Micro GC J&W CP-Volamine Channels

Brochures and specifications | 2024 | Agilent TechnologiesInstrumentation
GC
Industries
Manufacturer
Agilent Technologies

Summary

Importance of Topic


The analysis of light volatile compounds, especially amines and small oxygenates, is critical across environmental monitoring, industrial process control, and safety applications. Rapid, robust, and portable gas chromatography systems enable on-site quality assurance, leak detection, and compliance testing without the delays and logistics of central laboratories.

Goals and Overview of the Article


This data sheet introduces the Agilent 990 Micro GC equipped with J&W CP-Volamine channels. It outlines the channel configurations, column chemistries, and performance specifications designed for sensitive, high-throughput analysis of volatile amines, formaldehyde, dimethyl ether, ammonia, and similar compounds.

Methodology and Instrumentation


The Agilent 990 Micro GC integrates microfabricated components to deliver fast separations in a compact footprint.
  • Inlet and Injection
    • MEMS-based micromachined inlet with no moving parts
    • Software-selectable injection volume (1–10 µL) and time
    • Heated injector and transfer line up to 110 °C
  • Separation Column
    • J&W CP-Volamine nonpolar stationary phase tailored for volatile amines
    • Multi-Purpose Deactivation (MPD) for symmetrical peak shapes
    • Available lengths: 15 m, straight or backflush configurations
  • Detection
    • Micromachined thermal conductivity detector (TCD) with dual-channel (sample/reference)
    • Internal detector volume: 200 nL per channel
  • Pneumatics and Control
    • Independent column pressure programming
    • Choice of carrier gases: He, H₂, N₂, or Ar at 550 ± 10 kPa

Main Results and Discussion


Performance metrics for the 15 m CP-Volamine channel demonstrate:
  • Resolution (i-C₄/n-C₄ at 0.15/0.2%): 2.0
  • Detection limit (as n-C₅): 0.8 ppm
  • Peak area repeatability at 0.15/0.2%: < 1.0 % RSD

Backflush options (standard BF and BF2D) allow removal of heavier matrix compounds, preserving column lifetime and improving cycle time. The CP-Volamine phase maintains stability and symmetry even in humid samples, making it suitable for trace ammonia and amine measurements.

Benefits and Practical Applications


The key advantages include:
  • Rapid analysis—typical run times under a few minutes
  • Portability—compact GC ideal for field deployment
  • Robustness—no moving injector parts and water-tolerant stationary phase
  • Versatility—multiple column chemistries and backflush modes

Common use cases span environmental air monitoring, process gas leak detection, industrial hygiene, and quality control of specialty gases.

Future Trends and Possibilities


Emerging directions for micro GC technology and CP-Volamine channels include:
  • Integration of real-time data analytics and AI-driven peak identification
  • Further miniaturization of detectors for lower power consumption
  • Development of novel stationary phases for broader analyte ranges
  • Enhanced multiplexing to allow simultaneous multi-channel operation

Conclusion


The Agilent 990 Micro GC with CP-Volamine channels delivers a high-performance, field-ready solution for rapid analysis of volatile amines and small gases. Its microfabricated design, water-tolerant phase, and flexible backflush options provide reliable, reproducible results for diverse applications in environmental, industrial, and safety monitoring.

Reference


Agilent Technologies. Agilent 990 Micro GC J&W CP-Volamine Channels Data Sheet, 5994-7606EN, July 2024.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
990 Micro GC - Data Sheet Compendium
990 Micro GC - Data Sheet Compendium
2025|Agilent Technologies|Brochures and specifications
990 Micro GC Data Sheet Compendium Table of Contents Data sheets for 990 Micro GC 990 Micro GC 3 990 Mobile Micro GC 6 990-PRO Micro GC 9 Data sheets for 990 analytical channels CP-Molsieve 5Å 12 Hayesep A 14…
Key words
channel, channelyes, yesmicromachined, micromachinedtcd, tcdselectable, selectableprecolumn, precolumndetector, detectorlength, lengthinjector, injectorfilaments, filamentsbackflush, backflushsea, seaporaplot, poraplothayesep, hayesepcontrol
Agilent 990 Micro GC J&W CP-PoraPLOT Q Channels
Agilent 990 Micro GC J&W CP-PoraPLOT Q Channels
2024|Agilent Technologies|Brochures and specifications
Data Sheet Agilent 990 Micro GC J&W CP‑PoraPLOT Q Channels Introduction The Agilent 990 Micro GC system has been designed to accommodate up to four analytical channels. Each channel holds its own MEMS-based inlet, isothermal column, and micro TCD detector.…
Key words
yes, yesmicromachined, micromachinedporaplot, poraplotchannel, channelprecolumn, precolumntcd, tcdbackflush, backflushnoncondensing, noncondensingrepeatability, repeatabilitylength, lengthporabond, porabonddetector, detectorinjector, injectorvalco, valcofilaments
Agilent 990 Micro GC J&W CP-COX Channels
Agilent 990 Micro GC J&W CP-COX Channels
2024|Agilent Technologies|Brochures and specifications
Data Sheet Agilent 990 Micro GC J&W CP-COX Channels Introduction The Agilent 990 Micro GC system has been designed to accommodate up to four analytical channels. Each channel holds its own MEMS-based inlet, isothermal column, and micro TCD detector. These…
Key words
precolumn, precolumnmicromachined, micromachinedcox, coxchannel, channeltcd, tcdyes, yeslength, lengthporabond, porabonddetector, detectorinjector, injectorcarbon, carbonfilaments, filamentsselectable, selectabledescription, descriptionsea
Agilent 990 Micro GC CP-Al2O3/KCl Channels
Agilent 990 Micro GC CP-Al2O3/KCl Channels
2024|Agilent Technologies|Brochures and specifications
Data Sheet Agilent 990 Micro GC CP-Al2O3/KCl Channels Introduction The Agilent 990 Micro GC system has been designed to accommodate up to four analytical channels. Each channel holds its own MEMS-based inlet, isothermal column, and micro TCD detector. These channels…
Key words
yes, yesmicromachined, micromachinedchannel, channelprecolumn, precolumntuned, tunedtcd, tcdbackflush, backflushdetector, detectornoncondensing, noncondensingoptional, optionallength, lengthinjector, injectorfilaments, filamentsselectable, selectabledescription
Other projects
LCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike