Agilent 8850 GC system
Brochures and specifications | 2025 | Agilent TechnologiesInstrumentation
Small-footprint gas chromatography systems are essential in modern analytical laboratories facing limited bench space, high sample throughput demands, and sustainability goals. By combining high performance with a compact design, the Agilent 8850 GC addresses the need for efficient, reliable, and energy-conscious analyses.
This article reviews the design and capabilities of the Agilent 8850 GC system, focusing on its performance characteristics, operational benefits, and application versatility compared to traditional benchtop GCs.
The Agilent 8850 GC integrates advanced electronic pneumatics control (EPC) with a compact air-bath oven supporting temperature ramps up to 300 °C/min. Optional modules include helium conservation and hydrogen sensing. The system is compatible with:
Performance evaluations demonstrate that the 8850 GC matches the chromatographic precision and retention time repeatability of larger systems (8890 GC) while occupying half the bench space. Key findings include:
The 8850 GC enhances laboratory productivity through reduced downtime, simplified maintenance via guided diagnostics, and remote monitoring capabilities. Its modular design supports diverse applications in environmental testing, petrochemicals, pharmaceuticals, food safety, and advanced materials analysis.
Emerging directions include integration of intelligent diagnostics with cloud-based monitoring, expanded use of hydrogen or alternative carrier gases to conserve helium, and incorporation of AI-driven method optimization to further accelerate throughput and sustainability.
The Agilent 8850 GC system delivers high-performance gas chromatography in a minimal footprint, enabling laboratories to increase efficiency, reduce environmental impact, and maintain robust analytical capabilities across a wide range of applications.
GC
IndustriesOther
ManufacturerAgilent Technologies
Summary
Importance of the Topic
Small-footprint gas chromatography systems are essential in modern analytical laboratories facing limited bench space, high sample throughput demands, and sustainability goals. By combining high performance with a compact design, the Agilent 8850 GC addresses the need for efficient, reliable, and energy-conscious analyses.
Objectives and Study Overview
This article reviews the design and capabilities of the Agilent 8850 GC system, focusing on its performance characteristics, operational benefits, and application versatility compared to traditional benchtop GCs.
Methodology and Instrumentation Used
The Agilent 8850 GC integrates advanced electronic pneumatics control (EPC) with a compact air-bath oven supporting temperature ramps up to 300 °C/min. Optional modules include helium conservation and hydrogen sensing. The system is compatible with:
- Flame ionization detectors (FID)
- Thermal conductivity detectors (TCD)
- Single and triple quadrupole mass spectrometers (5977C, 7000E, 7010D)
- Split/splitless, multimode, and backflush inlets
- Automated sample preparation (PAL3 Series, headspace, SPME)
Main Results and Discussion
Performance evaluations demonstrate that the 8850 GC matches the chromatographic precision and retention time repeatability of larger systems (8890 GC) while occupying half the bench space. Key findings include:
- Up to 45% reduction in power consumption versus conventional GCs
- Fast analysis times: C30 hydrocarbon resolved in under 1.5 minutes at 200 °C/min ramp
- Comparable solvent and impurity profiling for ASTM D5769 and D7504 methods using helium or fast hydrogen carrier-gas approaches
- High sensitivity detection of carbonate additives in lithium battery electrolytes and NMP purity in industrial solvents
Benefits and Practical Applications
The 8850 GC enhances laboratory productivity through reduced downtime, simplified maintenance via guided diagnostics, and remote monitoring capabilities. Its modular design supports diverse applications in environmental testing, petrochemicals, pharmaceuticals, food safety, and advanced materials analysis.
Future Trends and Potential Applications
Emerging directions include integration of intelligent diagnostics with cloud-based monitoring, expanded use of hydrogen or alternative carrier gases to conserve helium, and incorporation of AI-driven method optimization to further accelerate throughput and sustainability.
Conclusion
The Agilent 8850 GC system delivers high-performance gas chromatography in a minimal footprint, enabling laboratories to increase efficiency, reduce environmental impact, and maintain robust analytical capabilities across a wide range of applications.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
The Analysis of Monocyclic Aromatic Hydrocarbons by ASTM D7504 on the Agilent 8850 GC System
2024|Agilent Technologies|Applications
Application Note Energy and Chemicals The Analysis of Monocyclic Aromatic Hydrocarbons by ASTM D7504 on the Agilent 8850 GC System Conventional and high‑speed approaches using helium or hydrogen carrier gas Author Scott Hoy Agilent Technologies, Inc. Abstract This application note…
Key words
xylene, xyleneppmw, ppmwbenzene, benzeneethylbenzene, ethylbenzenetoluene, toluenersd, rsdcheck, checkfid, fidbutylbenzene, butylbenzenebalance, balancemonocyclic, monocyclicpropylbenzene, propylbenzenerms, rmsaverage, averageconventional
Efficient. Easy. Economical. Effective. This Is How You GC - Agilent GC productivity resources
2020|Agilent Technologies|Brochures and specifications
Efficient. Easy. Economical. Effective. This Is How You GC Agilent GC productivity resources We’re Committed to Making Your GC Analysis Everything It Can Be For over 55 years, Agilent has led the way with industry-changing GC and GC/MS instruments, consumables,…
Key words
agilent, agilentyour, yourbrochure, brochurevideos, videoswebinar, webinargas, gassmart, smartyou, youhelium, heliumalerts, alertsresources, resourcestightening, tighteninguniversity, universitypage, pagecrosslab
Agilent 8890 gas chromatography system
2019|Agilent Technologies|Brochures and specifications
Intelligent and Configurable: Meet Your Analytical Needs Today and Tomorrow Agilent 8890 gas chromatography system 2 How Much Is an Hour of Your Time Worth? Whether you manage a lab that's large or small, contract or in-house, your challenges as…
Key words
your, youragilent, agilentdetector, detectorinert, inertyou, youonboard, onboardmaintenance, maintenancesystem, systeminlet, inletguided, guidedfpd, fpdsample, sampleultra, ultraflexible, flexiblescreen
Small Size Big Impact Agilent 8850 GC
2024|Agilent Technologies|Others
Small Size Big Impact Agilent 8850 GC Keep samples flowing through your lab by working smarter, not larger Limited bench space. Sustainability goals and rising energy costs. Pressure to turn around more samples in less time. Faced with these challenges,…
Key words
touch, touchbuyback, buybackscreen, screenhassle, hasslethink, thinkhuge, hugesmall, smallfamiliar, familiarflowing, flowingcloser, closerinlets, inletshome, homesmallest, smallestbig, bigyour