Comparison of 37 Component FAME Standard on Four Capillary GC Columns
Applications | 1996 | MerckInstrumentation
The accurate profiling of fatty acid methyl esters is essential for food quality control, nutritional labeling compliance, and research into health-related lipid composition. A standardized FAME mix and optimized chromatographic methods streamline analysis across diverse food matrices.
This study evaluates the separation performance of a 37-component FAME standard on four capillary GC columns of varying polarity: a bonded polyethylene glycol phase (Omegawax 250), a polyalkylene glycol phase (PAG), and two cyanosilicone phases (SP-2380, SP-2560). The goal is to compare elution patterns, resolve isomeric overlaps, and recommend a strategy for comprehensive FAME confirmation.
The comparative evaluation demonstrates that pairing a polyethylene glycol-based column with a cyanosilicone column using the Supelco 37 Component FAME Mix achieves optimal separation and confirmation of a wide range of fatty acid methyl esters. This dual-column strategy supports accurate, efficient FAME analysis for regulatory, nutritional, and research applications.
GC, GC columns, Consumables
IndustriesFood & Agriculture
ManufacturerMerck
Summary
Importance of the Topic
The accurate profiling of fatty acid methyl esters is essential for food quality control, nutritional labeling compliance, and research into health-related lipid composition. A standardized FAME mix and optimized chromatographic methods streamline analysis across diverse food matrices.
Objectives and Overview of the Study
This study evaluates the separation performance of a 37-component FAME standard on four capillary GC columns of varying polarity: a bonded polyethylene glycol phase (Omegawax 250), a polyalkylene glycol phase (PAG), and two cyanosilicone phases (SP-2380, SP-2560). The goal is to compare elution patterns, resolve isomeric overlaps, and recommend a strategy for comprehensive FAME confirmation.
Methodology and Instrumentation
- Sample: Supelco 37 Component FAME Mix containing C4:0–C24:1 methyl esters in methylene chloride (10 mg/mL).
- Gas Chromatography: Split injection (100:1) at 250 °C; flame ionization detection at 260 °C; helium as carrier gas.
- Columns and Oven Programs:
- Omegawax 250: 30 m × 0.25 mm × 0.25 µm; 50 °C (2 min) to 220 °C at 4 °C/min, hold 15 min.
- PAG: 30 m × 0.25 mm × 0.25 µm; same temperature ramp as Omegawax.
- SP-2380: 30 m × 0.25 mm × 0.20 µm; 50 °C (2 min) to 250 °C at 4 °C/min, hold 15 min.
- SP-2560: 100 m × 0.25 mm × 0.20 µm; 140 °C (5 min) to 240 °C at 4 °C/min, hold 15 min.
Main Results and Discussion
- Omegawax 250 and PAG columns elute FAMEs primarily by carbon chain length and degree of unsaturation; PAG shows reduced overlap for highly unsaturated long-chain FAMEs.
- Cyanosilicone columns (SP-2380, SP-2560) separate cis/trans isomers effectively, with trans isomers eluting before cis. SP-2560 provides superior geometric isomer resolution.
- High-polarity cyanosilicone phases exhibit overlap of polyunsaturated trienoic FAMEs with higher even-carbon saturated FAMEs, potentially complicating peak identification.
- A combined approach—injecting one sample across PEG and cyanosilicone columns in series—yields complementary elution profiles for reliable FAME confirmation.
Benefits and Practical Applications of the Method
- Comprehensive identification of saturated, monounsaturated, polyunsaturated, and trans FAMEs in complex food samples (milk, oils, fish, meat).
- Enhanced confidence in cis/trans isomer quantification to meet regulatory labeling requirements.
- Time and cost efficiency through use of a single standardized FAME mix and dual-column confirmation strategy.
Future Trends and Potential Applications
- Development of mixed-mode stationary phases combining carbon-chain and isomeric selectivity.
- Integration of multidimensional GC or GC×GC coupled to high-resolution mass spectrometry for structural elucidation of novel FAME isomers.
- Automation of sequential column switching workflows for high-throughput food quality and nutritional analysis.
Conclusion
The comparative evaluation demonstrates that pairing a polyethylene glycol-based column with a cyanosilicone column using the Supelco 37 Component FAME Mix achieves optimal separation and confirmation of a wide range of fatty acid methyl esters. This dual-column strategy supports accurate, efficient FAME analysis for regulatory, nutritional, and research applications.
Used Instrumentation
- Gas chromatograph with flame ionization detector (FID).
- Helium carrier gas; split injection (100:1).
- Columns: Omegawax 250 (30 m × 0.25 mm × 0.25 µm), PAG (30 m × 0.25 mm × 0.25 µm), SP-2380 (30 m × 0.25 mm × 0.20 µm), SP-2560 (100 m × 0.25 mm × 0.20 µm).
- Column temperature programs as described above.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Comparison of New 37 Component FAME Standard on Four Capillary Columns of Different Polarities
1999|Merck|Applications
TheReporter Reprinted from Volume 15, No. 1, 1996 T296011 © 1999 Sigma-Aldrich Co. For more information, or current prices, contact your nearest Supelco subsidiary listed below. To obtain further contact information, visit our website (www.sigma-aldrich.com), see the Supelco catalog, or…
Key words
cyanosilicone, cyanosiliconecolumns, columnsfames, famesnumbered, numberedsupelco, supelcofame, famefood, foodcarbon, carbonbeverage, beveragecis, cissaturated, saturatedglycol, glycoldifferences, differenceselution, elutionisomers
Analyzing Fatty Acids by Capillary Gas Chromatography
1998|Merck|Guides
Bulletin 855B Analyzing Fatty Acids by Capillary Gas Chromatography Described here are capillary gas chromatographic analyses of volatile and nonvolatile fatty acids, including cis/trans isomers, in free form and as methyl esters. Choose from conditions under which these compounds are…
Key words
supelco, supelcomin, minfatty, fattynukol, nukolacids, acidsfid, fidcis, cisisomers, isomersfames, fameselution, elutionpositional, positionalfused, fusedtrans, transcolumn, columndifferences
Supelco Ionic Iiquid GC columns - Applications
2012|Merck|Presentations
Supelco Ionic Liquid GC Columns Applications This presentation shows a variety of application which can be performed using Supelco ionic liquid GC columns. 1 Supelco Ionic Liquid GC Columns Applications Chromatograms – Environmental Applications 2 Supelco Ionic Liquid GC Columns…
Key words
supelco, supelcoionic, ioniccolumns, columnsapplications, applicationsliquid, liquidids, idsconditions, conditionspeg, pegxylene, xylenepeak, peakmethoxide, methoxidetrifluoride, trifluorideboron, boronchromatograms, chromatogramsoil
Reproducible Analyses of Omega-3 and Omega-6 Fatty Acid Methyl Esters by Capillary GC
1994|Merck|Applications
Application Note 34 Reproducible Analyses of Omega-3 and Omega-6 Fatty Acid Methyl Esters by Capillary GC Omegawax 250 and Omegawax 320 bonded polyethylene glycol phase columns were designed specifically for analyses of omega-3 and omega-6 fatty acid methyl esters. They…
Key words
chain, chainlength, lengthfatty, fattyequivalent, equivalentpeg, pegcolumn, columnesters, esterssecondarily, secondarilyvalues, valuesomegawax, omegawaxecl, eclsynthetically, syntheticallyconsistent, consistentdifferences, differencesacids